Model validation is an essential part of CFD-based projects. Despite being successfully employed for decades, the level and extent of CFD model validation details vary significantly in the published literature, which, in turn, adversely affects the repeatability and usefulness of published models and data. This study explores the various challenges associated with validating CFD models of thermodynamic components, namely, the compressors and their performance evaluation. The methodology involves blade generation through TurboGrid and BladeGen, mesh generation to ensure computational efficiency, and pre-processing with CFX to define boundary conditions and turbulence models, all within ANSYS 2024 R1. Three case studies are discussed, each assessing different compressor configurations and common challenges encountered during the model validation stage. Based on the case studies, a number of recommendations are presented relating to best practices in terms of both the use of published materials to validate new models and the level of detail required for experimental or simulation publication to ensure they can be replicated or used to validate a new model.

27 July 2026 in Processes
Verified
Journal Article
Open access
PDF file
JDJordan Dickenson
Jordan Dickenson
JBJames Bull
James Bull
JRJovana Radulovic
Jovana Radulovic
James M. BuickJames M. Buick
James M. Buick
The phasing out of high-GWP refrigerants and the growing diversity of working fluids used across heat pumps, refrigeration systems, and closed-cycle power applications have made drop-in fluid replacement a question of significant practical interest. Centrifugal compressors are designed around the thermophysical properties of a specific fluid, and the performance penalty is incurred when working fluid is replaced without redesigning the impeller. This study presents a CFD comparison of direct drop-in fluid replacement in a fixed geometry centrifugal compression system. Eight working fluids that span the property range relevant to current drop-in substitutions are evaluated: air, nitrogen, argon, carbon dioxide, R22, R134a, R1234yf, and R1234ze(E). A reference centrifugal impeller was reconstructed in ANSYS BladeGen, meshed in ANSYS TurboGrid using the Automatic Topology and Meshing method, and simulated in ANSYS CFX (2024 R2) as a single periodic passage with Frozen Rotor interfaces and Spalart–Allmaras turbulence closure. Performance maps were generated for each fluid across a range of rotational speeds and mass flow rates, with a common inlet reference condition applied across all cases to isolate the influence of fluid properties from an inlet state. The resulting dataset enables a like-for-like comparison of pressure ratio, efficiency, and shaft power requirement, providing a basis for assessing the aerodynamic implications of drop-in fluid substitution in centrifugal compression systems. Air, nitrogen, argon and carbon dioxide achieved similar peak efficiencies (~88%) and comparable pressure ratios (PR), indicating they can be used as drop-in substitutes without performance loss. Refrigerants R1234yf and R1234ze(E) matched R134a in efficiency (peak ~90%) while offering higher pressure ratios and significantly lower power requirements at peak efficiency. At 20,000 RPM and a mass flow rate of 2 kg/s, compared to a PR of 1.45 for air, nitrogen, carbon dioxide and argon achieved PRs of 1.4, 1.9 and 2.4, respectively. At the same settings, R134a and R1234 refrigerants reached PRs of 5 and 6, respectively. The power requirement was ~8 × 104 W for air and similar fluids, and ~11 × 104 W for refrigerants.

23 October 2026 in Processes
Verified
Journal Article
Open access
PDF file
JDJordan Dickenson
Jordan Dickenson
JBJames Bull
James Bull
JRJovana Radulovic
Jovana Radulovic
James M. BuickJames M. Buick
James M. Buick
The phase-out of high-GWP refrigerants means working fluids are increasingly replaced in compressors already designed and sized for the original fluid. Assessing the fluid replacement in a fixed geometry is complicated by the choice of operating parameter: at a matched mass flow rate, fluids with different densities will exhibit different volumetric flow. This study uses the flow coefficient as the main flow-side operating parameter, with the mass flow rate being calculated individually for each fluid and rotational speed so that all fluids are compared at the matched non-dimensional operating point. Eight working fluids—air, nitrogen, argon, carbon dioxide, R22, R134a, R1234yf and R1234ze(E)—were simulated in a single fixed-geometry centrifugal impeller geometry using ANSYS CFX 2024 R2 across six rotational speeds from 10,000 to 20,000 RPM and six flow coefficients. The efficiency optima of all eight fluids cluster to a common flow coefficient between 0.0636 and 0.0697. However, the width of the characteristic and the onset of choke remain fluid-dependent. While the low-density fluids operate over the full range of flow coefficients, the refrigerants exhibit choke at the higher end of the flow coefficient range, a feature which increases with the rotational velocity.