In order to find the causes of statistical line loss abnormalities and propose better loss reduction strategies, it is necessary to improve the accuracy of theoretical line loss calculations. Since Distributed Generation (DG) access to the distribution network causes variability of power flow in the distribution network within a short period, the error of the traditional line loss calculation method increases. For the line loss calculation of medium-voltage distribution networks containing DGs with high-density collection data, a continuous line loss calculation method for the distribution network was proposed, aiming at improving the accuracy compared with the traditional line loss calculation method. The proposed method makes full use of the high-density collection data on the dispatch side and DG side, distributing the supply power to each load node by power to calculate real-time power flow, thus obtaining a more credible line loss value. The effectiveness and accuracy of the proposed method were verified in the IEEE 17-node distribution system.
Data collection is more difficult in distribution network than transmission networks since the structure of distribution networks is more complex. As a result, data could be partly abnormal or missing, which cannot completely describe the operation status of distribution network. In addition, access of distributed generation (DG) to distribution network further aggravates the variability of power flow in distribution network. The traditional deterministic line loss calculation method has some limitations in accurately estimating the line loss of distribution network with DG. A line loss interval calculation method based on power flow calculation and linear optimization is proposed, considering abnormal data collection and distribution network power flow variability. The linear optimization model is established according to sensitivity of line loss to the injected power and sensitivity of transmission power of first branch to the injected power. Introducing the scheduling information into the optimization model, a reliable line loss fluctuation interval can be obtained which actual line loss locates. The effectiveness of the proposed algorithm is verified in IEEE 33-bus distribution network system.
One of the primary causes of additional losses in dry-type distribution transformers is harmonic disturbances in the distribution network. It is critical to investigate the change law of trans-former losses under harmonic conditions. The effect of harmonics on transformer core losses and winding losses is first investigated in this paper. The field-circuit coupling method is then used to create a finite element model of a three-phase phase dry type distribution transformer. Finally, the relationship between core loss and harmonic voltage, winding loss and harmonic current is calculated and analyzed for each harmonic frequency. The AC resistance factor model is found to be more accurate than the conventional model in calculating transformer harmonic winding losses. This paper’s findings have significant theoretical implications for the analysis of harmonic losses and loss reduction in distribution networks.
In view of the current problem of insufficient consideration being taken of the effect of voltage control and the adjustment cost in the voltage control strategy of distribution networks containing photovoltaic (PV) and energy storage (ES), a multi-stage optimization control method considering grouping collaboration is proposed. Firstly, the mechanism by which the access of the PV and ES to the distribution network impacts the node voltage is explored. Then, the unit regulation cost of a photovoltaic inverter and energy storage power is studied. On this basis, the voltage–cost sensitivity is proposed based on the traditional node power–node voltage sensitivity. According to the differences between each group of regulation resources, a multi-stage voltage over-run control strategy based on grouping cooperation is proposed. Finally, the improved 33-node model is taken as an example to verify the correctness and effectiveness of the proposed method.
With the increasing penetration of renewable energy, traditional distribution network operation state assessment methods based on typical operating conditions are no longer applicable. It is urgent to conduct risk assessment research on the dynamic coupling characteristics of voltage, power flow, and distributed generation output after photovoltaic integration into active distribution networks. This paper first analyzes the spatiotemporal variation characteristics of power flow distribution and voltage fluctuations in active distribution networks, and proposes evaluation indicators for power flow and voltage over limit risks. Secondly, feature quantities related to the over limit risk assessment indicators are selected, and a distribution network over limit risk assessment method based on TCN-Transformer neural network architecture is proposed. Finally, based on the improved IEEE 33 node distribution network model, an active distribution network simulation model is built in Matlab (2023b), and a simulation dataset is constructed for multiple operating scenarios. On this basis, a comparative analysis of risk assessment examples for power flow and voltage exceeding limits is conducted, and the results verify the effectiveness and superiority of the proposed method.
19 April 2021 in Discrete Dynamics in Nature and Society
With the increase in the proportion of clean energy connected to the grid, the effective coordination of the operation of various energy power has become a new challenge facing the current power system scheduling. The coordinated operation of the clean energy power generation system can alleviate the contradiction between power generation and output power fluctuations and overcome the bottleneck of new energy development. Considering the natural characteristics of clean energy, this paper aims to make full use of clean energy, reduce system operating costs, increase system power generation, and reduce output fluctuations; we establish a multiobjective optimization model for coordinated scheduling of clean energy power systems. The model seeks to maximize power generation and minimize output fluctuations, power purchase costs, and maintenance costs under the constraints of the grid structure. In this paper, the joint algorithm has an accelerated effect on the target optimization calculation, and then the superiority of the algorithm is verified by the standard system. The standard IEEE39 node test system is used to verify the rationality and feasibility of the model built and provides a reference strategy for the coordinated operation mechanism of the clean energy system. According to the model, in the example in this paper, the maximum value of photovoltaic power prediction is 1290 MW, and the minimum value is 210 MW; the maximum value of wind power prediction is 780 MW, and the minimum value is 28 MW; the minimum cost of power purchase and maintenance is 56,950.395; the maximum generating capacity is 5.045 GW; the minimum output fluctuation is 0.120 GW.