Michael Gembicki

Dr. Michael Gembicki

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2019 in Journal of Ultrasound in Medicine
Verified
Journal Article
Open access
PDF file
MGMichael Gembicki
Michael Gembicki
DHDavid R. Hartge
David R. Hartge
CDChristoph Dracopoulos
Christoph Dracopoulos
JWJan Weichert
Jan Weichert
Objectives: To investigate the interobserver and intraobserver variability and corresponding learning curve in a semiautomatic approach for a standardized assessment of the fetal heart (fetal intelligent navigation echocardiography [FINE]).Methods: A total of 30 stored spatiotemporal image correlation volume data sets of second‐trimester fetuses were evaluated by 3 physicians with different levels of expertise in fetal echocardiography by using the FINE approach. Data were analyzed regarding the examination time and proper reconstruction of the diagnostic cardiac planes. The completions and numbers of correct depictions of all diagnostic planes were evaluated by a blinded expert (time t0). To determine interobserver and intraobserver variability, the volumes were reassessed after a 4‐week training interval (time t1).Results: All operators were able to perform the investigation on all 30 volumes. At t0, the interobserver variability between the beginner and both the advanced (P = .0013) and expert (P < .0001) examiners was high. Focusing on intraobserver variability at t1, the beginner showed a marked improvement (P = .0087), whereas in advanced and expert hands, no further improvement regarding proper achievement of all diagnostic planes could be noticed (P > .999; P = .8383). The beginner also showed improvement in the mean investigation time (t0, 82.8 seconds; t1, 73.4 seconds; P = .0895); nevertheless, the advanced and expert examiners were faster in completing the examination (t1, advanced, 20.9 seconds; expert, 28.3 seconds; each P < .0001).Conclusions: Based on our results, the FINE technique is a reliable and easily learned method. The use of this semiautomatic work flow–based approach supports evaluation of the fetal heart in a standardized and time‐saving manner. A semiautomatic evaluation of the fetal heart might be useful in facilitating the detection of fetal cardiac anomalies.

11 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
JSJann Lennard Scharf
Jann Lennard Scharf
CDChristoph Dracopoulos
Christoph Dracopoulos
MGMichael Gembicki
Michael Gembicki
AWAmrei Welp
Amrei Welp
Jan WeichertJan Weichert
Jan Weichert
(1) Objectives: In utero functional cardiac assessments using echocardiography have become increasingly important. The myocardial performance index (MPI, Tei index) is currently used to evaluate fetal cardiac anatomy, hemodynamics and function. An ultrasound examination is highly examiner-dependent, and training is of enormous significance in terms of proper application and subsequent interpretation. Future experts will progressively be guided by applications of artificial intelligence, on whose algorithms prenatal diagnostics will rely on increasingly. The objective of this study was to demonstrate the feasibility of whether less experienced operators might benefit from an automated tool of MPI quantification in the clinical routine. (2) Methods: In this study, a total of 85 unselected, normal, singleton, second- and third-trimester fetuses with normofrequent heart rates were examined by a targeted ultrasound. The modified right ventricular MPI (RV-Mod-MPI) was measured, both by a beginner and an expert. A calculation was performed semiautomatically using a Samsung Hera W10 ultrasound system (MPI+™, Samsung Healthcare, Gangwon-do, South Korea) by taking separate recordings of the right ventricle’s in- and outflow using a conventional pulsed-wave Doppler. The measured RV-Mod-MPI values were assigned to gestational age. The data were compared between the beginner and the expert using a Bland-Altman plot to test the agreement between both operators, and the intraclass correlation was calculated. (3) Results: The mean maternal age was 32 years (19 to 42 years), and the mean maternal pre-pregnancy body mass index was 24.85 kg/m2 (ranging from 17.11 to 44.08 kg/m2). The mean gestational age was 24.44 weeks (ranging from 19.29 to 36.43 weeks). The averaged RV-Mod-MPI value of the beginner was 0.513 ± 0.09, and that of the expert was 0.501 ± 0.08. Between the beginner and the expert, the measured RV-Mod-MPI values indicated a similar distribution. The statistical analysis showed a Bland-Altman bias of 0.01136 (95% limits of agreement from −0.1674 to 0.1902). The intraclass correlation coefficient was 0.624 (95% confidence interval from 0.423 to 0.755). (4) Conclusions: For experts as well as for beginners, the RV-Mod-MPI is an excellent diagnostic tool for the assessment of fetal cardiac function. It is a time-saving procedure, offers an intuitive user interface and is easy to learn. There is no additional effort required to measure the RV-Mod-MPI. In times of reduced resources, such assisted systems of fast value acquisition represent clear added value. The establishment of the automated measurement of the RV-Mod-MPI in clinical routine should be the next level in cardiac function assessment.

18 October 2022 in Tomography
Verified
Journal Article
Open access
PDF file
JSJan A. M. Sochurek
Jan A. M. Sochurek
MGMichael Gembicki
Michael Gembicki
Salvatore GrisantiSalvatore Grisanti
Salvatore Grisanti
MRMahdy Ranjbar
Mahdy Ranjbar
(1) Purpose: To evaluate the anatomy and perfusion of choroidal substructures in third-trimester pregnant women using optical coherence tomography (OCT) and OCT angiography (OCTA) imaging. (2) Methods: In this cross-sectional study, women in their third trimester of uncomplicated pregnancy and non-pregnant age-matched women were recruited. Participants underwent enhanced depth imaging (EDI) OCT and OCTA. Subfoveal choroidal thickness (SFCT), as well as choroidal sublayer perfusion, were compared between groups. (3) Results: In total, 26 eyes of 26 pregnant and 26 eyes of 26 non-pregnant women were included. The median age in both groups was 29 years. The median SFCT was 332 (211–469) µm in the pregnant group and 371.5 (224–466) µm in the non-pregnant cohort (p = 0.018). The median choriocapillaris perfusion (CCP) was significantly lower in the pregnant group (46% vs. 48%, p = 0.039). Moreover, Haller’s layer perfusion correlated significantly with mean arterial pressure in non-pregnant women (CC = 0.430, p = 0.028) but not in pregnant ones (CC = 0.054, p = 0.792). (4) Conclusions: SFCT was found to be thinner and CCP was lower in third-trimester pregnant women. Hormonal changes during pregnancy and consecutive impacts on autoregulation of small choroidal vessels might play an important role. Therefore, altered choroidal measurements during third-trimester pregnancy should be carefully evaluated as, to some extent, it could be a normal physiological change.

16 August 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MGMichael Gembicki
Michael Gembicki
AWAmrei Welp
Amrei Welp
JSJann Lennard Scharf
Jann Lennard Scharf
CDChristoph Dracopoulos
Christoph Dracopoulos
Jan WeichertJan Weichert
Jan Weichert
(1) Objective: We aimed to evaluate the accuracy and efficacy of AI-assisted biometric measurements of the fetal central nervous system (CNS) by comparing two semiautomatic postprocessing tools. We further aimed to discuss the additional value of semiautomatically generated sagittal and coronal planes of the CNS. (2) Methods: Three-dimensional (3D) volumes were analyzed with two semiautomatic software tools, 5DCNS+™ and SonoCNS™. The application of 5DCNS+™ results in nine planes (axial, coronal and sagittal) displayed in a single template; SonoCNS™ depicts three axial cutting sections. The tools were compared regarding automatic biometric measurement accuracy. (3) Results: A total of 129 fetuses were included for final analysis. Our data indicate that, in terms of the biometric quantification of head circumference (HC), biparietal diameter (BPD), transcerebellar diameter (TCD) and cisterna magna (CM), the accuracy of SonoCNS™ was higher with respect to the manual measurement of an experienced examiner compared to 5DCNS+™, whereas it was the other way around regarding the diameter of the posterior horn of the lateral ventricle (Vp). The inclusion of four orthogonal coronal views in 5DCNS+™ gives valuable information regarding spatial arrangements, particularly of midline structures. (4) Conclusions: Both tools were able to ease assessment of the intracranial anatomy, highlighting the additional value of automated algorithms in clinical use. SonoCNS™ showed a superior accuracy of plane reconstruction and biometry, but volume reconstruction using 5DCNS+™ provided more detailed information, which is needed for an entire neurosonogram as suggested by international guidelines.

5 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AWAlexander Weichert
Alexander Weichert
MGMichael Gembicki
Michael Gembicki
Jan WeichertJan Weichert
Jan Weichert
SWSven Hristian Weber
Sven Hristian Weber
Josefine Theresia KoenigbauerJosefine Theresia Koenigbauer
Josefine Theresia Koenigbauer
Congenital heart disease (CHD) is one of the most common organ-specific birth defects and a major cause of infant morbidity and mortality. Despite ultrasound screening guidelines, the detection rate of CHD is limited. Fetal intelligent navigation echocardiography (FINE) has been introduced to extract reference planes and cardiac axis from cardiac spatiotemporal image correlation (STIC) volume datasets. This study analyses the cardiac axis in fetuses affected by CHD/thoracic masses (n = 545) compared to healthy fetuses (n = 1543) generated by FINE. After marking seven anatomical structures, the FINE software generated semi-automatically nine echocardiography standard planes and calculated the cardiac axis. Our study reveals that depending on the type of CHD, the cardiac axis varies. In approximately 86% (471 of 542 volumes) of our pathological cases, an abnormal cardiac axis (normal median = 40–45°) was detectable. Significant differences between the fetal axis of the normal heart versus CHD were detected in HLHS, pulmonary atresia, TOF (p-value < 0.0001), RAA, situs ambiguus (p-value = 0.0001–0.001) and absent pulmonary valve syndrome, DORV, thoracic masses (p-value = 0.001–0.01). This analysis confirms that in fetuses with CHD, the cardiac axis can significantly deviate from the normal range. FINE appears to be a valuable tool to identify cardiac defects.

1 January 2021 in Journal of Ultrasound in Medicine
Verified
Journal Article
Open access
PDF file
MGMichael Gembicki
Michael Gembicki
DHDavid R. Hartge
David R. Hartge
TFTheresa Fernandes
Theresa Fernandes
JWJan Weichert
Jan Weichert
Objectives We investigated the feasibility of a semiautomatic approach for assessments of the fetal heart (fetal intelligent navigation echocardiography [FINE]) in cases of optimal and unfavorable fetal spine positions. Methods In this study, a total of 1693 spatiotemporal image correlation volumes of first-, second-, and third-trimester fetuses were evaluated by experts using the FINE approach. The data were analyzed regarding proper reconstruction of the diagnostic cardiac planes depending on the fetal spine position. Results A total of 1531 volumes were included. The volumes were divided into 4 groups depending on the fetal spine position: 5-7 o'clock, 4 + 8 o'clock, 3 + 9 o'clock, and 2 + 10 o'clock. In total, 93.2% of the diagnostic planes were displayed properly. Between 5 and 7 o'clock, 94.9% of the diagnostic planes were displayed properly. The correct depiction rates in the other groups were 92.4% (4 + 8 o'clock; n = 538;P= 0.0027), 88.3% (3 + 9 o'clock; n = 156;P < .0001), and 87.3% (2 + 10 o'clock; n = 41;P= .0139). In total, the highest dropout rates were found in the sagittal planes: ductal arch, 13.9%; aortic arch, 10.5%; and venae cavae, 12.0%. Conclusions Based on our results, the FINE technique is an effective method, but its feasibility depends on the fetal position. The use of this semiautomatic work flow-based approach supports evaluation of the fetal heart in a standardized manner. Semiautomatic evaluation of the fetal heart might be useful in facilitating the detection of fetal cardiac anomalies.