Jann Lennard Scharf

Dr. Jann Lennard Scharf

Department of Gynecology and Obstetrics, University Hospital of Schleswig-Holstein, Campus Lübeck, Lübeck, Schleswig-Holstein, Germany
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Jan WeichertJan Weichert
Jan Weichert
JSJann Lennard Scharf
Jann Lennard Scharf
The detailed sonographic assessment of the fetal neuroanatomy plays a crucial role in prenatal diagnosis, providing valuable insights into timely, well-coordinated fetal brain development and detecting even subtle anomalies that may impact neurodevelopmental outcomes. With recent advancements in artificial intelligence (AI) in general and medical imaging in particular, there has been growing interest in leveraging AI techniques to enhance the accuracy, efficiency, and clinical utility of fetal neurosonography. The paramount objective of this focusing review is to discuss the latest developments in AI applications in this field, focusing on image analysis, the automation of measurements, prediction models of neurodevelopmental outcomes, visualization techniques, and their integration into clinical routine.

11 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
JSJann Lennard Scharf
Jann Lennard Scharf
CDChristoph Dracopoulos
Christoph Dracopoulos
MGMichael Gembicki
Michael Gembicki
AWAmrei Welp
Amrei Welp
Jan WeichertJan Weichert
Jan Weichert
(1) Objectives: In utero functional cardiac assessments using echocardiography have become increasingly important. The myocardial performance index (MPI, Tei index) is currently used to evaluate fetal cardiac anatomy, hemodynamics and function. An ultrasound examination is highly examiner-dependent, and training is of enormous significance in terms of proper application and subsequent interpretation. Future experts will progressively be guided by applications of artificial intelligence, on whose algorithms prenatal diagnostics will rely on increasingly. The objective of this study was to demonstrate the feasibility of whether less experienced operators might benefit from an automated tool of MPI quantification in the clinical routine. (2) Methods: In this study, a total of 85 unselected, normal, singleton, second- and third-trimester fetuses with normofrequent heart rates were examined by a targeted ultrasound. The modified right ventricular MPI (RV-Mod-MPI) was measured, both by a beginner and an expert. A calculation was performed semiautomatically using a Samsung Hera W10 ultrasound system (MPI+™, Samsung Healthcare, Gangwon-do, South Korea) by taking separate recordings of the right ventricle’s in- and outflow using a conventional pulsed-wave Doppler. The measured RV-Mod-MPI values were assigned to gestational age. The data were compared between the beginner and the expert using a Bland-Altman plot to test the agreement between both operators, and the intraclass correlation was calculated. (3) Results: The mean maternal age was 32 years (19 to 42 years), and the mean maternal pre-pregnancy body mass index was 24.85 kg/m2 (ranging from 17.11 to 44.08 kg/m2). The mean gestational age was 24.44 weeks (ranging from 19.29 to 36.43 weeks). The averaged RV-Mod-MPI value of the beginner was 0.513 ± 0.09, and that of the expert was 0.501 ± 0.08. Between the beginner and the expert, the measured RV-Mod-MPI values indicated a similar distribution. The statistical analysis showed a Bland-Altman bias of 0.01136 (95% limits of agreement from −0.1674 to 0.1902). The intraclass correlation coefficient was 0.624 (95% confidence interval from 0.423 to 0.755). (4) Conclusions: For experts as well as for beginners, the RV-Mod-MPI is an excellent diagnostic tool for the assessment of fetal cardiac function. It is a time-saving procedure, offers an intuitive user interface and is easy to learn. There is no additional effort required to measure the RV-Mod-MPI. In times of reduced resources, such assisted systems of fast value acquisition represent clear added value. The establishment of the automated measurement of the RV-Mod-MPI in clinical routine should be the next level in cardiac function assessment.

1 January 2022 in Journal of Medical Education and Curricular Development
Verified
Journal Article
Open access
JSJann Lennard Scharf
Jann Lennard Scharf
ABArne Bringewatt
Arne Bringewatt
CDChristoph Dracopoulos
Christoph Dracopoulos
ARAchim Rody
Achim Rody
JWJan Weichert
Jan Weichert
MGMichael Gembicki
Michael Gembicki
For 300 years now, obstetrics has drawn on the concept of simulation training to not only teach anatomy and physiology theoretically, but to literally infuse it practically. In an 18th century scientific culture, which was predominantly patriarchal, the French royal midwife Angelique Marguerite Le Boursier du Coudray excelled in this field. Using La Machine, one of the first obstetric phantoms, she taught thousands of midwives and even physicians. The exponential increase in publications on obstetric simulations in recent years continues to underline their current relevance, and Madame du Coudray was once at the forefront with her mannequin, probably the most sophisticated phantom of its time, a symbiosis of practical-robust architecture and anatomical-theoretical accuracy. In retrospect, it is therefore worthwhile to take a closer look at this pioneer and her obstetric phantoms, applied in the first national simulation-based training course, and to evaluate them in the overall picture of the development of anatomically correct replicas for practice-oriented training with detailed, flexible exercise – back to the roots.

16 August 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MGMichael Gembicki
Michael Gembicki
AWAmrei Welp
Amrei Welp
JSJann Lennard Scharf
Jann Lennard Scharf
CDChristoph Dracopoulos
Christoph Dracopoulos
Jan WeichertJan Weichert
Jan Weichert
(1) Objective: We aimed to evaluate the accuracy and efficacy of AI-assisted biometric measurements of the fetal central nervous system (CNS) by comparing two semiautomatic postprocessing tools. We further aimed to discuss the additional value of semiautomatically generated sagittal and coronal planes of the CNS. (2) Methods: Three-dimensional (3D) volumes were analyzed with two semiautomatic software tools, 5DCNS+™ and SonoCNS™. The application of 5DCNS+™ results in nine planes (axial, coronal and sagittal) displayed in a single template; SonoCNS™ depicts three axial cutting sections. The tools were compared regarding automatic biometric measurement accuracy. (3) Results: A total of 129 fetuses were included for final analysis. Our data indicate that, in terms of the biometric quantification of head circumference (HC), biparietal diameter (BPD), transcerebellar diameter (TCD) and cisterna magna (CM), the accuracy of SonoCNS™ was higher with respect to the manual measurement of an experienced examiner compared to 5DCNS+™, whereas it was the other way around regarding the diameter of the posterior horn of the lateral ventricle (Vp). The inclusion of four orthogonal coronal views in 5DCNS+™ gives valuable information regarding spatial arrangements, particularly of midline structures. (4) Conclusions: Both tools were able to ease assessment of the intracranial anatomy, highlighting the additional value of automated algorithms in clinical use. SonoCNS™ showed a superior accuracy of plane reconstruction and biometry, but volume reconstruction using 5DCNS+™ provided more detailed information, which is needed for an entire neurosonogram as suggested by international guidelines.

14 June 2024 in Echocardiography
Verified
Journal Article
Open access
JSJann Lennard Scharf
Jann Lennard Scharf
CDChristoph Dracopoulos
Christoph Dracopoulos
MGMichael Gembicki
Michael Gembicki
ARAchim Rody
Achim Rody
AWAmrei Welp
Amrei Welp
Jan WeichertJan Weichert
Jan Weichert
Background: Prenatal echocardiographic assessment of fetal cardiac function has become increasingly important. Fetal two‐dimensional speckle‐tracking echocardiography (2D‐STE) allows the determination of global and segmental functional cardiac parameters. Prenatal diagnostics is relying increasingly on artificial intelligence, whose algorithms transform the way clinicians use ultrasound in their daily workflow. The purpose of this study was to demonstrate the feasibility of whether less experienced operators can handle and might benefit from an automated tool of 2D‐STE in the clinical routine.Methods: A total of 136 unselected, normal, singleton, second‐ and third‐trimester fetuses with normofrequent heart rates were examined by targeted ultrasound. 2D‐STE was performed separately by beginner and expert semiautomatically using a GE Voluson E10 (FetalHQ®, GE Healthcare, Chicago, IL). Several fetal cardiac parameters were calculated (end‐diastolic diameter [ED], sphericity index [SI], global longitudinal strain [EndoGLS], fractional shortening [FS]) and assigned to gestational age (GA). Bland‐Altman plots were used to test agreement between both operators.Results: The mean maternal age was 33 years, and the mean maternal body mass index prior to pregnancy was 24.78 kg/m2. The GA ranged from 16.4 to 32.0 weeks (average 22.9 weeks). Averaged endoGLS value of the beginner was ‐18.57% ± 6.59 percentage points (pp) for the right and ‐19.58% ± 5.63 pp for the left ventricle, that of the expert ‐14.33% ± 4.88 pp and ‐16.37% ± 5.42 pp. With increasing GA, right ventricular endoGLS decreased slightly while the left ventricular was almost constant. The statistical analysis for endoGLS showed a Bland‐Altman‐Bias of ‐4.24 pp ± 8.06 pp for the right and ‐3.21 pp ± 7.11 pp for the left ventricle. The Bland‐Altman‐Bias of the ED in both ventricles in all analyzed segments ranged from ‐.49 mm ± 1.54 mm to ‐.10 mm ± 1.28 mm, that for FS from ‐.33 pp ± 11.82 pp to 3.91 pp ± 15.56 pp and that for SI from ‐.38 ± .68 to ‐.15 ± .45.Conclusions: Between both operators, our data indicated that 2D‐STE analysis showed excellent agreement for cardiac morphometry parameters (ED and SI), and good agreement for cardiac function parameters (EndoGLS and FS). Due to its complexity, the application of fetal 2D‐STE remains the domain of scientific‐academic perinatal ultrasound and should be placed preferably in the hands of skilled operators. At present, from our perspective, an implementation into clinical practice “on‐the‐fly” cannot be recommended.

21 July 2021 in Clinical Case Reports
Verified
Journal Article
Open access
PDF file
JSJann Lennard Scharf
Jann Lennard Scharf
MGMichael Gembicki
Michael Gembicki
CDChristoph Dracopoulos
Christoph Dracopoulos
YHYorck Hellenbroich
Yorck Hellenbroich
AOAnne Offermann
Anne Offermann
JWJan Weichert
Jan Weichert
The delineation of the prenatal diagnostic key features of PIK3CA‐related overgrowth spectrum disorders will assume a crucial part in future and a prenatal diagnosis of the causing mutations would provide physicians with a simplified interdisciplinary perinatal management.