Miguel Garcia

Dr. Miguel Garcia


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Solar Energy
Verified
Journal Article
Open access
JMJavier Marcos
Javier Marcos
OSO. Storkël
O. Storkël
LMLuis Marroyo
Luis Marroyo
MGMiguel Garcia
Miguel Garcia
ELE. Lorenzo
E. Lorenzo
Short-term variability in the power generated by large grid-connected photovoltaic (PV) plants can negatively affect power quality and the network reliability. New grid-codes require combining the PV generator with some form of energy storage technology in order to reduce short-term PV power fluctuation. This paper proposes an effective method in order to calculate, for any PV plant size and maximum allowable ramp-rate, the maximum power and the minimum energy storage requirements alike. The general validity of this method is corroborated with extensive simulation exercises performed with real 5-s one year data of 500 kW inverters at the 38.5 MW Amaraleja (Portugal) PV plant and two other PV plants located in Navarra (Spain), at a distance of more than 660 km from Amaraleja

21 July 2011 in Progress in Photovoltaics: Research and Applications
Verified
Journal Article
Open access
PDF file
JMJavier Marcos
Javier Marcos
LMLuis Marroyo
Luis Marroyo
ELEduardo Lorenzo
Eduardo Lorenzo
MGMiguel Garcia
Miguel Garcia
The quality and the reliability of the power generated by large grid‐connected photovoltaic (PV) plants are negatively affected by the source characteristic variability. This paper deals with the smoothing of power fluctuations because of geographical dispersion of PV systems. The fluctuation frequency and the maximum fluctuation registered at a PV plant ensemble are analyzed to study these effects. We propose an empirical expression to compare the fluctuation attenuation because of both the size and the number of PV plants grouped. The convolution of single PV plants frequency distribution functions has turned out to be a successful tool to statistically describe the behavior of an ensemble of PV plants and determine their maximum output fluctuation. Our work is based on experimental 1‐s data collected throughout 2009 from seven PV plants, 20 MWp in total, separated between 6 and 360 km. Copyright © 2011 John Wiley & Sons, Ltd.

23 February 2011 in Progress in Photovoltaics: Research and Applications
Verified
Journal Article
Closed access
PDF file
MGMiguel Garcia
Miguel Garcia
LMLuis Marroyo
Luis Marroyo
ELEduardo Lorenzo
Eduardo Lorenzo
MPMiguel Pérez
Miguel Pérez

16 October 2014 in Energies
Verified
Journal Article
Open access
PDF file
JMJavier Marcos
Javier Marcos
IPIñigo De la Parra
Iñigo De la Parra
MGMiguel Garcia
Miguel Garcia
LMLuis Marroyo
Luis Marroyo
The variations in irradiance produced by changes in cloud cover can cause rapid fluctuations in the power generated by large photovoltaic (PV) plants. As the PV power share in the grid increases, such fluctuations may adversely affect power quality and reliability. Thus, energy storage systems (ESS) are necessary in order to smooth power fluctuations below the maximum allowable. This article first proposes a new control strategy (step-control), to improve the results in relation to two state-of-the-art strategies, ramp-rate control and moving average. It also presents a method to quantify the storage capacity requirements according to the three different smoothing strategies and for different PV plant sizes. Finally, simulations shows that, although the moving-average (MA) strategy requires the smallest capacity, it presents more losses (2–3 times more) and produces a much higher number of cycles over the ESS (around 10 times more), making it unsuitable with storage technologies as lithium-ion. The step-control shown as a better option in scenery with exigent ramp restrictions (around 2%/min) and distributed generation against the ramp-rate control in all ESS key aspects: 20% less of capacity, up to 30% less of losses and a 40% less of ageing. All the simulations were based on real PV production data, taken every 5 s in the course of one year (2012) from a number of systems with power outputs ranging from 550 kW to 40 MW.

1 October 2017 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
IPI. de la Parra
I. de la Parra
MMM. Muñoz
M. Muñoz
ELE. Lorenzo
E. Lorenzo
MGMiguel Garcia
Miguel Garcia
JMJavier Marcos
Javier Marcos
FMF. Martínez-Moreno
F. Martínez-Moreno

1 January 2015 in Solar Energy
Verified
Journal Article
Closed access
IPI. de la Parra
I. de la Parra
JMJavier Marcos
Javier Marcos
MGMiguel Garcia
Miguel Garcia
LMLuis Marroyo
Luis Marroyo