Yuki Yoshida

Dr. Yuki Yoshida

Keio University, Tokyo, Japan
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
NMNoboru Matsumura
Noboru Matsumura
YYYoshitake Yamada
Yoshitake Yamada
SOSatoshi Oki
Satoshi Oki
YYYuki Yoshida
Yuki Yoshida
YYYoichi Yokoyama
Yoichi Yokoyama
MJMasahiro Jinzaki
Masahiro Jinzaki
Background: Although humans spend most of their day in a standing or sitting position, it is difficult to accurately evaluate the alignment of the shoulder girdle during daily activity, and its alignment changes between positions. The purpose of this study was to evaluate the 3-dimensional alignment of the shoulder girdle in the supine and standing positions by computed tomography (CT) and to assess the alignment changes of the shoulder girdle between these two positions. Methods: CT scans of both shoulders of 100 healthy volunteers were prospectively taken in both supine and standing positions on the same day. The local 3-dimensional coordinate systems of the thorax, clavicle, and scapula were defined from the specific bony landmarks, and 3-dimensional angular rotations and positions of the clavicle and scapula were calculated. Differences in rotations and positions of the clavicle and scapula were evaluated between the supine and standing positions. Results: Compared with the supine position, the clavicle showed significantly less elevation and greater retraction, and the scapula showed significantly less upward rotation, anterior tilting, and internal rotation in the standing position. Compared with the supine position, the clavicle center was located more inferiorly, posteriorly, and laterally, and the scapula center was located more inferiorly, posteriorly, and medially in the standing position. Conclusions: The present study showed that angular rotations and positions of the clavicle and scapula change significantly with position due to the effect of gravity.

20 May 2019 in Menopause
Verified
Journal Article
Open access
IGIrwin Goldstein
Irwin Goldstein
JSJames A. Simon
James A. Simon
AKAndrew M. Kaunitz
Andrew M. Kaunitz
CACorrado Altomare
Corrado Altomare
YYYuki Yoshida
Yuki Yoshida
GSGraziella Soulban
Graziella Soulban
Objective: To prospectively evaluate the effects of ospemifene on the vulva and vagina in postmenopausal women using vulvar-vestibular photography and direct visual assessments. Methods: Postmenopausal women (aged 40-80 years) with moderate to severe vaginal dryness as their most bothersome symptom (MBS) were randomized to daily ospemifene 60 mg or placebo in this 12-week, multicenter, double-blind, phase 3 study. Vulvar-vestibular photographic images were captured at baseline and week 12 and were independently assessed with the Vulvar Imaging Assessment Scale (VIAS). Changes from baseline in Vaginal and Vulvar Health Indices (VHI and VuHI) with ospemifene versus placebo were analyzed at weeks 4, 8, and 12. Correlations between VIAS, VHI, and VuHI, with vaginal dryness severity and the Female Sexual Function Index (FSFI) scores were also assessed. Results: In all, 631 eligible participants were randomized (ospemifene 316, placebo 315) and included in the intention-to-treat population. Compared with placebo, ospemifene significantly improved total scores for VIAS (P = 0.0154), VHI (P < 0.0001), and VuHI (P < 0.0001) from baseline to week 12; significant VHI (P < 0.0001) and VuHI (P = 0.002) improvements were observed at week 4. Most VHI and VuHI individual items were significantly better with ospemifene versus placebo at week 12 (P < 0.05). Most correlations between the vulvovaginal assessment total scores versus vaginal dryness severity and FSFI scores were significant (P < 0.05). Conclusion: Improvements observed in vulvovaginal health with ospemifene assessed by prospective vulvar-vestibular photography and other direct visual assessments support its efficacy in addition to the treatment of moderate to severe vaginal dryness due to menopause and the use of photographic and direct visual evaluations in future clinical trials. Video Summary: Supplemental Digital Content 1, http://links.lww.com/MENO/A415

23 September 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
YYYuki Yoshida
Yuki Yoshida
NMNoboru Matsumura
Noboru Matsumura
YYYoshitake Yamada
Yoshitake Yamada
MYMinoru Yamada
Minoru Yamada
YYYoichi Yokoyama
Yoichi Yokoyama
MJMasahiro Jinzaki
Masahiro Jinzaki
Background: Narrowing of the acromiohumeral distance (AHD) implies a rotator cuff tear. However, conventional AHD measurements using two-dimensional (2D) imaging or with the patient in the supine position might differ from that while standing during daily activity. This study aimed to evaluate the three-dimensional (3D) actual distance between the acromion and humeral head in the standing position and compare the AHD values with those obtained using conventional measuring methods. Methods: Computed tomography (CT) images of 166 shoulders from 83 healthy volunteers (31 male and 52 female; mean age 40.1 ± 5.8 years; age range, 30–49 years) were prospectively acquired in the supine and standing positions using conventional and upright CT scanners, respectively. The minimum distance between the acromion and humeral head on the 3D surface models was considered as the 3D AHD. We measured the 2D AHD on anteroposterior digitally reconstructed radiographs. The AHD values were compared between the supine and standing positions and between the 2D and 3D measurements. Results: The mean values of 2D AHD were 8.8 ± 1.3 mm (range, 5.9–15.4 mm) in the standing position and 8.1 ± 1.2 mm (range, 5.3–14.3 mm) in the supine position. The mean values of 3D AHD were 7.3 ± 1.4 mm (range, 4.7–14.0 mm) in the standing position and 6.6 ± 1.2 mm (range, 4.4–13.7 mm) in the supine position. The values of 3D AHD were significantly lower than those of 2D AHDs in both the standing and supine positions (P < 0.001). The values of 2D and 3D AHDs were significantly lower in the supine position than in the standing position (P < 0.001). Conclusions: This study evaluated the 3D AHD of normal shoulders in the standing position using an upright CT scanner. The present results indicated that assessments in the supine position can underestimate the value of the AHD compared with those made in the standing position and that assessments using 2D analysis can overestimate the value.

29 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YYYuki Yoshida
Yuki Yoshida
NMNoboru Matsumura
Noboru Matsumura
YYYoshitake Yamada
Yoshitake Yamada
MYMinoru Yamada
Minoru Yamada
YYYoichi Yokoyama
Yoichi Yokoyama
MJMasahiro Jinzaki
Masahiro Jinzaki
Motion capture systems using skin markers are widely used to evaluate scapular kinematics. However, soft-tissue artifact (STA) is a major limitation, and there is insufficient knowledge of the marker movements from the original locations. This study explores a scapular STA, including marker movements with shoulder elevation using upright computed tomography (CT). Ten healthy males (twenty shoulders in total) had markers attached to scapular bony landmarks and underwent upright CT in the reference and elevated positions. Marker movements were calculated and compared between markers. The bone-based and marker-based scapulothoracic rotation angles were also compared in both positions. The median marker movement distances were 30.4 mm for the acromial angle, 53.1 mm for the root of the scapular spine, and 70.0 mm for the inferior angle. Marker movements were significantly smaller on the superolateral aspect of the scapula, and superior movement was largest in the directional movement. Scapulothoracic rotation angles were significantly smaller in the marker-based rotation angles than in the bone-based rotation angles of the elevated position. We noted that the markers especially did not track the inferior movement of the scapular motion with shoulder elevation, resulting in an underestimation of the marker-based rotation angles.

30 April 2022 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
YYYuki Yoshida
Yuki Yoshida
NMNoboru Matsumura
Noboru Matsumura
AMAzusa Miyamoto
Azusa Miyamoto
SOSatoshi Oki
Satoshi Oki
YYYoichi Yokoyama
Yoichi Yokoyama
MJMasahiro Jinzaki
Masahiro Jinzaki

1 January 2016 in Journal of Epidemiology
Verified
Journal Article
Open access
MOMasaki Ohsawa
Masaki Ohsawa
KTKozo Tanno
Kozo Tanno
Tomonori OkamuraTomonori Okamura
Tomonori Okamura
YYYuki Yonekura
Yuki Yonekura
KKKaren Kato
Karen Kato
AOAkira Okayama
Akira Okayama
While it is assumed that dialysis patients in Japan have a higher prevalence of atrial fibrillation (AF) than the general population, the magnitude of this difference is not known. Standardized prevalence ratios (SPRs) for AF in dialysis patients (n = 1510) were calculated compared to data from the general population (n = 26 454) living in the same area. The prevalences of AF were 3.8% and 1.6% in dialysis patients and the general population, respectively. In male subjects, these respective values were 4.9% and 3.3%, and in female subjects they were 1.6% and 0.6%. The SPRs for AF were 2.53 (95% confidence interval [CI], 1.88-3.19) in all dialysis patients, 1.80 (95% CI, 1.30-2.29) in male dialysis patients, and 2.13 (95% CI, 0.66-3.61) in female dialysis patients. The prevalence of AF in dialysis patients was twice that in the population-based controls. Since AF strongly contributes to a higher risk of cardiovascular mortality and morbidity in the general population, further longitudinal studies should be conducted regarding the risk of several outcomes attributable to AF among Japanese dialysis patients.