Roman Beigelbeck

Dr. Roman Beigelbeck


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2015 in Sensors
Verified
Journal Article
Open access
PDF file
ATAlmir Talic
Almir Talic
SCSamir Cerimovic
Samir Cerimovic
RBRoman Beigelbeck
Roman Beigelbeck
FKFranz Kohl
Franz Kohl
TSThilo Sauter
Thilo Sauter
FKFranz Keplinger
Franz Keplinger
A thermal flow transduction method combining the advantages of calorimetric and hot-film transduction principles is developed and analyzed by Finite Element Method (FEM) simulations and confirmed experimentally. The analyses include electrothermal feedback effects of current driven NTC thermistors. Four thin-film germanium thermistors acting simultaneously as heat sources and as temperature sensors are embedded in a micromachined silicon-nitride membrane. These devices form a self-heated Wheatstone bridge that is unbalanced by convective cooling. The voltage across the bridge and the total dissipated power are exploited as output quantities. The used thin-film thermistors feature an extremely high temperature sensitivity. Combined with properly designed resistance values, a power demand in sub-1mW range enables efficient gas-flow transduction, as confirmed by measurements. Two sensor configurations with different arrangements of the membrane thermistors were examined experimentally. Moreover, we investigated the influence of different layouts on the rise time, the sensitivity, and the usable flow range by means of two-dimensional finite element simulations. The simulation results are in reasonable agreement with corresponding measurement data confirming the basic assumptions and modeling approach.

2 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
TGThomas Glatzl
Thomas Glatzl
RBRoman Beigelbeck
Roman Beigelbeck
SCSamir Cerimovic
Samir Cerimovic
HSHarald Steiner
Harald Steiner
FWFlorian Wenig
Florian Wenig
FKFranz Keplinger
Franz Keplinger
We present a thermal flow sensor designed for measuring air as well as water flow velocities in heating, ventilation, and air conditioning (HVAC) systems. The sensor is designed to integrate the flow along the entire diameter of the pipe also quantifying the volume flow rate of the streaming fluid where the calorimetric principle in constant temperature operation is utilized as a readout method. In the constant temperature mode, a controller keeps a specific excess temperature between sensing elements at a constant level resulting in a flow dependent heater voltage. To achieve cost-effective sensors, the fabrication of the transducer is fully based on printed circuit board technology allowing low-cost mass production with different form factors. In addition, 2D-FEM simulations were carried out in order to predict the sensor characteristic of envisaged setups. The simulation enables a fast and easy way to evaluate the sensor’s behaviour in different fluids. The results of the FEM simulations are compared to measurements in real environments, proving the credibility of the model.

21 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SCSamir Cerimovic
Samir Cerimovic
ATAlbert Treytl
Albert Treytl
TGThomas Glatzl
Thomas Glatzl
RBRoman Beigelbeck
Roman Beigelbeck
FKFranz Keplinger
Franz Keplinger
TSThilo Sauter
Thilo Sauter
We investigated non-invasive flow rate measurements in heating, ventilation, and air conditioning (HVAC) systems utilizing thermal transduction instead of commonly used ultrasonic techniques. The proposed thermal flow transduction comprises two temperature sensors and a heater, all mounted non-invasively on the outer surface of metal-pipes and, therefore, not disturbing the fluid flow inside. One temperature sensor measures the heater temperature, whereas the other one, mounted upstream of the heater, follows the fluid temperature for reference. The temperature difference (i.e., the heater excess temperature) depends on the fluid flow velocity and can be used to derive the mean volume flow inside the pipe. Experimental characterizations were conducted using two sensor prototypes. Beside output characteristics, other main issues such as dynamic behavior and noise density were investigated in detail. Special attention was paid to error compensation allowing measurements within a large range of fluid temperatures. Measurement results confirm the feasibility of this approach, however with some constraints regarding response time.

24 December 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
SCSamir Cerimovic
Samir Cerimovic
ATAlbert Treytl
Albert Treytl
TGThomas Glatzl
Thomas Glatzl
RBRoman Beigelbeck
Roman Beigelbeck
FKFranz Keplinger
Franz Keplinger
TSThilo Sauter
Thilo Sauter
We present a feasibility study on non‐invasive flow rate measurements in heating, ventilation, and air conditioning (HVAC) systems utilizing thermal transduction instead of commonly used ultrasonic techniques. The investigated thermal flow transduction comprises two temperature sensors and a heater, all mounted non‐invasively on the outer pipe surface and, therefore, not disturbing the fluid flow inside. One temperature sensor measures the heater temperature, whereas the other one, mounted upstream of the heater, follows the fluid temperature for reference. The temperature difference (i.e., the heater excess temperature) depends on the fluid velocity and can be used to derive the mean volume flow inside the pipe. In order to visualize and study the temperature field, a finite element method (FEM) model of the system was implemented. Measurements conducted with the sensor prototype confirm the feasibility of this approach.

3 December 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
TGThomas Glatzl
Thomas Glatzl
RBRoman Beigelbeck
Roman Beigelbeck
SCSamir Cerimovic
Samir Cerimovic
HSHarald Steiner
Harald Steiner
ATAlbert Treytl
Albert Treytl
We present finite element method (FEM) simulations of a thermal flow sensor as well as a comparison to measurement results. The thermal sensor is purely based on printed circuit board (PCB) technology, designed for heating, ventilation, and air conditioning (HVAC) systems. Design and readout method of the sensor enables the possibility to measure the flow velocity in various fluids. 2D-FEM simulations were carried out in order to predict the sensor characteristic of envisaged setups. The simulations enable a fast and easy way to evaluate the sensor’s behaviour in different fluids. The results of the FEM simulations are compared to measurements in a real environment, proving the credibility of the model.

15 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ATAlmir Talic
Almir Talic
SCSamir Cerimovic
Samir Cerimovic
RBRoman Beigelbeck
Roman Beigelbeck
FKFranz Kohl
Franz Kohl
TSThilo Sauter
Thilo Sauter
FKFranz Keplinger
Franz Keplinger
This paper reports on a design and simulation study aiming at high-accuracy 2D micromachined thermal flow transducers. The scope is restricted to micromachined devices featuring a square-shaped membrane incorporating central symmetric thin-film devices. A microthermistor array probed spatial excess temperature variations while the main heat supply was alternatively established by optional heating resistors or by pronounced self-heating of the thermistor devices. Proper device designs enable leading edge transducer performance without sophisticated signal conditioning schemes. We found that a high azimuthal uniformity of flow magnitude transduction is tantamount to a precise azimuthal accuracy. The most advanced result gave a maximum azimuthal aberration of 0.17 and 1.7 degrees for 1 m/s and 10 m/s, respectively, while the corresponding magnitude uniformity amounted to 0.07% and 0.5%. Such excellent specifications exceed the need of ordinary meteorological applications by far. However, they are essential for, e.g., precise non-contact measurements of 2D relative movements of two quasi-planar surfaces via the related Couette flow in intermediate air gaps. The simulations predicted significantly better device characteristics than achieved by us in first experiments. However, this gap could be attributed to imperfect control of the flow velocity field by the measurement setup.