A thermal flow transduction method combining the advantages of calorimetric and hot-film transduction principles is developed and analyzed by Finite Element Method (FEM) simulations and confirmed experimentally. The analyses include electrothermal feedback effects of current driven NTC thermistors. Four thin-film germanium thermistors acting simultaneously as heat sources and as temperature sensors are embedded in a micromachined silicon-nitride membrane. These devices form a self-heated Wheatstone bridge that is unbalanced by convective cooling. The voltage across the bridge and the total dissipated power are exploited as output quantities. The used thin-film thermistors feature an extremely high temperature sensitivity. Combined with properly designed resistance values, a power demand in sub-1mW range enables efficient gas-flow transduction, as confirmed by measurements. Two sensor configurations with different arrangements of the membrane thermistors were examined experimentally. Moreover, we investigated the influence of different layouts on the rise time, the sensitivity, and the usable flow range by means of two-dimensional finite element simulations. The simulation results are in reasonable agreement with corresponding measurement data confirming the basic assumptions and modeling approach.
This paper reports on a design and simulation study aiming at high-accuracy 2D micromachined thermal flow transducers. The scope is restricted to micromachined devices featuring a square-shaped membrane incorporating central symmetric thin-film devices. A microthermistor array probed spatial excess temperature variations while the main heat supply was alternatively established by optional heating resistors or by pronounced self-heating of the thermistor devices. Proper device designs enable leading edge transducer performance without sophisticated signal conditioning schemes. We found that a high azimuthal uniformity of flow magnitude transduction is tantamount to a precise azimuthal accuracy. The most advanced result gave a maximum azimuthal aberration of 0.17 and 1.7 degrees for 1 m/s and 10 m/s, respectively, while the corresponding magnitude uniformity amounted to 0.07% and 0.5%. Such excellent specifications exceed the need of ordinary meteorological applications by far. However, they are essential for, e.g., precise non-contact measurements of 2D relative movements of two quasi-planar surfaces via the related Couette flow in intermediate air gaps. The simulations predicted significantly better device characteristics than achieved by us in first experiments. However, this gap could be attributed to imperfect control of the flow velocity field by the measurement setup.
Although capacitive and piezoresistive readouts are commonly used for microelectromechanical structures, they suffer from serious drawbacks like limited range of displacement, inherent nonlinearity, insucient sensitivity, and technological complexity. Our complementary readout approach relies on a novel hybrid optomechanical device, where the displacement range is not limited by typical constraints of capacitive or piezoresistive conversion principles. Furthermore, no electrical connections are required on the micromechanical part. Moreover, this principle enables custom linear or nolinear output characteristics at the same technological effort.
We present a novel transient measurement method to characterize effective values of the thermal conductivity, thermal diffusivity, and emissivity of a thin-film membrane implemented in a micromachined multiparameter wind sensor. Accurate values for these parameters are mandatory as they considerably influence the thermal heat shunt induced by the membrane, which is the main limiting factor for reliable sensor operation in gases with low thermal admittance and thus determines the ultimate device sensitivity. Compared with commonly used measurement techniques for these thermal thin-film parameters, our method does not require custom-built specimens, i.e., the results can directly be obtained from transient excess temperature measurements on the wind sensor device utilizing the embedded thin-film heater and thermistors. The presented method as such is universal and can easily be applied to other configurations of heating and temperature sensing elements placed on a circular thin-film membrane. In this contribution, we describe the theoretical background of this method, provide an efficient semianalytical model for the data evaluation including its validation by computer numerical simulations, and showcase sample measurements on multilayer Si x N y -SiO 2 thin films.