We demonstrate computational ghost imaging at X-ray wavelengths with only one single-pixel detector. We show that, by using a known designed mask as a diffuser that induces intensity fluctuations in the probe beam, it is possible to compute the propagation of the electromagnetic field in the absence of the investigated object. We correlate these calculations with the measured data when the object is present in order to reconstruct the images of 50 μm and 80 μm slits. Our results open the possibilities for X-ray high-resolution imaging with partially coherent X-ray sources and can lead to a powerful tool for X-ray three-dimensional imaging.
Synchrotron light sources require X-ray optics with extremely demanding accuracy for the surface profile, with less than 100 nrad slope errors and sub-nanometre height errors. Such errors are challenging to achieve for aspheres using traditional polishing methods. However, post-polishing error correction can be performed using techniques such as ion beam figuring (IBF) to improve optics to the desired quality. This work presents a brief overview of the history of IBF, introduces some of the challenges for obtaining such demanding figure errors, and highlights the work done at several in-house IBF facilities at synchrotron light sources worldwide to obtain state-of-the-art optical quality.
1 January 2019 in Journal of Synchrotron Radiation
The tangential curvature of actively bent X-ray mirrors at synchrotron radiation and X-ray free-electron laser (XFEL) facilities is typically only changed every few hours or even days. This operation can take tens of minutes for active optics with multiple bending actuators and often requires expert guidance using in situ monitoring devices. Hence, the dynamic performance of active X-ray optics for synchrotron beamlines has historically not been exploited. This is in stark contrast to many other scientific fields. However, many areas of synchrotron radiation and XFEL science, including macromolecular crystallography, could greatly benefit from the ability to change the size and shape of the X-ray beam rapidly and continuously. The advantages of this innovative approach are twofold: a large reduction in the dead time required to change the size of the X-ray beam for different-sized samples and the possibility of making multiple changes to the beam during the measurement of a single sample. In the preceding paper [Part I; Alcock, Nistea, Signorato & Sawhney (2019), J. Synchrotron Rad.26, 36–44], which accompanies this article, high-speed visible-light Fizeau interferometry was used to identify the factors which influence the dynamic bending behaviour of piezoelectric bimorph deformable X-ray mirrors. Building upon this ex situ metrology study, provided here is the first synchrotron radiation beamline implementation of high-speed adaptive X-ray optics using two bimorphs operating as a Kirkpatrick–Baez pair. With optimized substrates, novel opto-mechanical holders and a next-generation high-voltage power supply, the size of an X-ray beam was rapidly and repeatedly switched in <10 s. Of equal importance, it is also shown that compensation of piezoelectric creep ensures that the X-ray beam size remains stable for more than 1 h after making a major change. The era of high-speed adaptive X-ray optics for synchrotron radiation and XFEL beamlines has begun.
1 January 2019 in Journal of Synchrotron Radiation
Piezoelectric bimorph deformable mirrors (`bimorphs') are routinely used on many synchrotron and free-electron laser beamlines to provide active variation in the size and shape of the X-ray beam. However, the time-domain potential of such optics has never been fully exploited. For the first time, the fast dynamic bending response of bimorphs is investigated here using Fizeau interferometry. Automated scripts for acquisition and analysis were developed to collect Fizeau data at a rate of 0.1 Hz to record dynamic changes in the optical surface as voltages were applied to the electrodes of the piezoelectric actuators. It is demonstrated that residual drift in the tangential radius of curvature of a bimorph can be significantly reduced using enhanced opto-mechanical holders and a fast programmable high-voltage power supply. Further improvements are achieved by applying small opposing voltages to compensate for piezoelectric creep. The present study shows that bimorphs can truly be used as high-speed adaptive optics for the X-ray domain, even without closed-loop feedback correction. This opens the possibility for relatively simple real-time tuning of the profile of X-ray bimorphs. Part II of this study [Alcock, Nistea, Signorato, Owen, Axford, Sutter, Foster & Sawhney (2019), J. Synchrotron Rad.26, 45–51] builds upon these results and demonstrates how bimorphs can rapidly provide customisable sizes and shapes of synchrotron X-ray beams, specifically tailored to suit the experimental samples being investigated.
1 February 2019 in Review of Scientific Instruments
Recently, the dynamic performance of piezo-electric deformable “bimorph” mirrors for synchrotron radiation and X-ray free electron laser sources has been characterized and significantly improved. This innovation enables high intensity X-ray beams to be rapidly focused or defocused to either match to the size of the sample under test or to select different sized regions of interest in larger samples. In this paper, we extend these results by monitoring a bimorph mirror using a combination of ex situ metrology instruments. Comparison between results from the Diamond-NOM (Nanometre Optical Metrology) slope profiler, a Fizeau interferometer, and Zygo ZPSTM distance measuring probes shows that bimorph X-ray mirrors can reliably and accurately be driven at 1 Hz using advanced features recently added to the high voltage (HV), bipolar “HV-Adaptos” power supply from CAEN.
The high flux of the white X-ray beams from third-generation synchrotron light sources can significantly benefit the development of high-speed X-ray imaging, but can also bring technical challenges to existing X-ray imaging systems. One prevalent problem is that the image quality deteriorates because of dust particles accumulating on the scintillator screen during exposure to intense X-ray radiation. Here, this problem has been solved by embedding the scintillator in a flowing inert-gas environment. It is also shown that the detector maintains the quality of the captured images even after days of X-ray exposure. This modification is cost-efficient and easy to implement. Representative examples of applications using the X-ray imaging system are also provided, including fast tomography and multimodal phase-contrast imaging for biomedical and geological samples.