Simon G. Alcock

Simon G. Alcock

Auto-generated profile, based on publicly available information

Simon G. Alcock

Diamond Light Source Ltd

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
MHM. Hoesch
M. Hoesch
TKT. K. Kim
T. K. Kim
PDP. Dudin
P. Dudin
HWH. Wang
H. Wang
SSS. Scott
S. Scott
FBF. Baumberger
F. Baumberger
A synchrotron radiation beamline in the photon energy range of 18-240 eV and an electron spectroscopy end station have been constructed at the 3 GeV Diamond Light Source storage ring. The instrument features a variable polarisation undulator, a high resolution monochromator, a re-focussing system to form a beam spot of 50 × 50 μm2, and an end station for angle-resolved photoelectron spectroscopy (ARPES) including a 6-degrees-of-freedom cryogenic sample manipulator. The beamline design and its performance allow for a highly productive and precise use of the ARPES technique at an energy resolution of 10-15 meV for fast k-space mapping studies with a photon flux up to 2 ⋅ 1013 ph/s and well below 3 meV for high resolution spectra.

22 February 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
KZKe-Jin Zhou
Ke-Jin Zhou
AWAndrew Walters
Andrew Walters
MGMirian Garcia-Fernandez
Mirian Garcia-Fernandez
TRThomas Rice
Thomas Rice
MHMatthew Hand
Matthew Hand
GHGeorge Howell
George Howell
The I21 beamline at Diamond Light Source is dedicated to advanced resonant inelastic X-ray scattering (RIXS) for probing charge, orbital, spin and lattice excitations in materials across condensed matter physics, applied sciences and chemistry. Both the beamline and the RIXS spectrometer employ divergent variable-line-spacing gratings covering a broad energy range of 280–3000 eV. A combined energy resolution of ∼35 meV (16 meV) is readily achieved at 930 eV (530 eV) owing to the optimized optics and the mechanics. Considerable efforts have been paid to the design of the entire beamline, particularly the implementation of the collection mirrors, to maximize the X-ray photon throughput. The continuous rotation of the spectrometer over 150° under ultra high vacuum and a cryogenic manipulator with six degrees of freedom allow accurate mappings of low-energy excitations from solid state materials in momentum space. Most importantly, the facility features a unique combination of the high energy resolution and the high photon throughput vital for advanced RIXS applications. Together with its stability and user friendliness, I21 has become one of the most sought after RIXS beamlines in the world.

15 March 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ASA. J. Smith
A. J. Smith
SAS. G. Alcock
S. G. Alcock
LDL. S. Davidson
L. S. Davidson
JEJ. H. Emmins
J. H. Emmins
JBJ. C. Hiller Bardsley
J. C. Hiller Bardsley
NTN. J. Terrill
N. J. Terrill
Beamline I22 at Diamond Light Source is dedicated to the study of soft-matter systems from both biological and materials science. The beamline can operate in the range 3.7 keV to 22 keV for transmission SAXS and 14 keV to 20 keV for microfocus SAXS with beam sizes of 240 µm × 60 µm [full width half-maximum (FWHM) horizontal (H) × vertical (V)] at the sample for the main beamline, and approximately 10 µm × 10 µm for the dedicated microfocusing platform. There is a versatile sample platform for accommodating a range of facilities and user-developed sample environments. The high brilliance of the insertion device source on I22 allows structural investigation of materials under extreme environments (for example, fluid flow at high pressures and temperatures). I22 provides reliable access to millisecond data acquisition timescales, essential to understanding kinetic processes such as protein folding or structural evolution in polymers and colloids.

1 January 2015 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
SASimon G. Alcock
Simon G. Alcock
INIoana Nistea
Ioana Nistea
JSJohn P. Sutter
John P. Sutter
KSKawal Sawhney
Kawal Sawhney
JFJean-Jacques Fermé
Jean-Jacques Fermé
LPLuca Peverini
Luca Peverini
Piezo bimorph mirrors are versatile active optics used on many synchrotron beamlines. However, many bimorphs suffer from the `junction effect': a periodic deformation of the optical surface which causes major aberrations to the reflected X-ray beam. This effect is linked to the construction of such mirrors, where piezo ceramics are glued directly below the thin optical substrate. In order to address this problem, a next-generation bimorph with piezos bonded to the side faces of a monolithic substrate was developed at Thales-SESO and optimized at Diamond Light Source. Using metrology feedback from the Diamond-NOM, the optical slope error was reduced to ∼0.5 µrad r.m.s. for a range of ellipses. To maximize usability, a novel holder was built to accommodate the substrate in any orientation. When replacing a first-generation bimorph on a synchrotron beamline, the new mirror significantly improved the size and shape of the reflected X-ray beam. Most importantly, there was no evidence of the junction effect even after eight months of continuous beamline usage. It is hoped that this new design will reinvigorate the use of active bimorph optics at synchrotron and free-electron laser facilities to manipulate and correct X-ray wavefronts.

5 November 2022 in Optics and Lasers in Engineering
Verified
Journal Article
Open access
MSMurilo B. da Silva
Murilo B. da Silva
SASimon G. Alcock
Simon G. Alcock
INIoana-Theodora Nistea
Ioana-Theodora Nistea
KSKawal Sawhney
Kawal Sawhney

21 May 2024 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
RSRiley Shurvinton
Riley Shurvinton
HWHongchang Wang
Hongchang Wang
PPParesh Chandra Pradhan
Paresh Chandra Pradhan
INIoana-Theodora Nistea
Ioana-Theodora Nistea
SASimon Alcock
Simon Alcock
Kawal SawhneyKawal Sawhney
Kawal Sawhney
Synchrotron light sources require X-ray optics with extremely demanding accuracy for the surface profile, with less than 100 nrad slope errors and sub-nanometre height errors. Such errors are challenging to achieve for aspheres using traditional polishing methods. However, post-polishing error correction can be performed using techniques such as ion beam figuring (IBF) to improve optics to the desired quality. This work presents a brief overview of the history of IBF, introduces some of the challenges for obtaining such demanding figure errors, and highlights the work done at several in-house IBF facilities at synchrotron light sources worldwide to obtain state-of-the-art optical quality.