Roberto Rosas-Romero

Dr. Roberto Rosas-Romero

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
GSGabriel Solana-Lavalle
Gabriel Solana-Lavalle
RRRoberto Rosas-Romero
Roberto Rosas-Romero
Qualitative and quantitative analyses of Magnetic Resonance Imaging (MRI) scans are carried out to study and understand Parkinson's Disease, the second most common neurodegenerative disorder in people at their 60's. Some quantitative analyses are based on the application of voxel-based morphometry (VBM) on magnetic resonance images to determine the regions of interest, within gray matter, where there is a loss of the nerve cells that generate dopamine. This loss of dopamine is indicative of Parkinson's disease. The purpose of this research is the introduction of a new method to classify the 3-D magnetic resonance scans of an individual, as an assisting tool for diagnosis of Parkinson's disease by using the largest MRI dataset (Parkinson's Progression Markers Initiative) from a population of patients with Parkinson's disease and control individuals. A contribution is that separate studies are conducted for men and women since gender plays a significant role within Neurobiology, which is demonstrated by the fact that men are more prone to Parkinson's disease than women are. Previous to classification, VBM is conducted on magnetic resonance images to detect the regions where features are extracted by using first- and second-order statistics methods. Furthermore, the number of features is considerably reduced by using feature selection techniques. Seven classifiers are used and we are conducting separate experiments for men and women. The best detection performance achieved in men is 99.01% of accuracy, 99.35% of sensitivity, 100% of specificity, and 100% of precision. The best detection performance achieved in women is 96.97% of accuracy, 100% of sensitivity, 96.15% of specificity, and 97.22% of precision. During classification of magnetic resonance images, the corresponding computational complexity is reduced since few features are selected. The proposed method provides high performance as an assisting tool in the diagnosis of Parkinson's disease, by conducting separate experiments in men and women. While previous works have focused their analysis to the striatum region of the brain (the largest nuclear complex of the basal ganglia), the proposed approach is based on analysis over the whole brain by looking for decreases of tissue thickness, with the consequence of finding other regions of interest such as the cortex.

1 January 2020 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Closed access
GSGabriel Solana-Lavalle
Gabriel Solana-Lavalle
JGJuan-Carlos Galán-Hernández
Juan-Carlos Galán-Hernández
RRRoberto Rosas-Romero
Roberto Rosas-Romero

1 September 2015 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
RRRoberto Rosas-Romero
Roberto Rosas-Romero
JMJorge Martínez-Carballido
Jorge Martínez-Carballido
HCHernandez Hernandez capistran
Hernandez Hernandez capistran
LULaura J. Uribe-Valencia
Laura J. Uribe-Valencia

1 August 2019 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
RRRoberto Rosas-Romero
Roberto Rosas-Romero
Edgar GuevaraEdgar Guevara
Edgar Guevara
KPKe Peng
Ke Peng
DNDang Khoa Nguyen
Dang Khoa Nguyen
FLFrédéric Lesage
Frédéric Lesage
WLWassim-Enrique Lima-Saad
Wassim-Enrique Lima-Saad

1 September 2016 in Expert Systems with Applications
Verified
Journal Article
Closed access
RRRoberto Rosas-Romero
Roberto Rosas-Romero
ADAlejandro Díaz-Torres
Alejandro Díaz-Torres
Gibran EtcheverryGibran Etcheverry
Gibran Etcheverry

1 August 2010
Verified
Conference Paper
Closed access
RGR. Gonzalez-Gonzalez
R. Gonzalez-Gonzalez
VAVicente Alarcon-Aquino
Vicente Alarcon-Aquino
RRRoberto Rosas-Romero
Roberto Rosas-Romero
OSO. Starostenko
O. Starostenko
JRJ. Rodriguez-Asomoza
J. Rodriguez-Asomoza
JRJ. M. Ramirez-Cortes
J. M. Ramirez-Cortes
In this paper an approach to detect smoke columns from outdoor forest video sequences is proposed. The approach follows three basic steps. The first step is an image pre-processing block which resizes the image by applying a bicubic interpolation algorithm. The image is then transformed to its intensity values with a gray-scale transformation and finally the image is grouped by common areas with an image indexation. The second step consists of a smoke detection algorithm which performs a stationary wavelet transform (SWT) to remove high frequencies on horizontal, vertical, and diagonal details. The inverse SWT is then implemented and finally the image is compared to a non-smoke scene in order to determine the possible regions of interest (ROI). In order to reduce the number of false alarms, the final step of the proposed approach consists on a smoke verification algorithm, which determines whether the ROI is increasing its area or not. These results are combined to reach a final decision for detecting a smoke column on a sequence of static images from an outdoor video. Experimental results show that multi-resolution wavelet analysis is more accurate than the traditional low-pass filters on this application.