Chun-Ta Tzeng

Dr. Chun-Ta Tzeng


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2013 in Sensors
Verified
Journal Article
Open access
PDF file
PCPo-Ren Chung
Po-Ren Chung
CTChun-Ta Tzeng
Chun-Ta Tzeng
MKMing-Tsun Ke
Ming-Tsun Ke
Chia-Yen LeeChia-Yen Lee
Chia-Yen Lee
Many methods based on spectrophotometric, fluorometric, piezoresistive, amperometric or conductive measurements have been proposed for detecting the concentration of formaldehyde in air. However, conventional formaldehyde measurement systems are bulky and expensive and require the services of highly-trained operators. Accordingly, the emergence of sophisticated technologies in recent years has prompted the development of many microscale gaseous formaldehyde detection systems. Besides their compact size, such devices have many other advantages over their macroscale counterparts, including a real-time response, a more straightforward operation, lower power consumption, and the potential for low-cost batch production. This paper commences by providing a high level overview of the formaldehyde gas sensing field and then describes some of the more significant real-time sensors presented in the literature over the past 10 years or so.

29 September 2015 in Energies
Verified
Journal Article
Open access
PDF file
CKChien-Yuan Kuo
Chien-Yuan Kuo
CTChun-Ta Tzeng
Chun-Ta Tzeng
MHMing-Chin Ho
Ming-Chin Ho
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
The pedestrian-level wind environment quality in street canyons formed by high-rise buildings and other low-level buildings could be affected by multiple factors, such as the height and geometry of the surrounding buildings, street width, wind direction, and wind speed. This study conducted wind tunnel experiments to determine the characteristics of the pedestrian-level wind environment in street canyons under different conditions, including different street widths, podium heights, and approaching wind directions. The experimental results revealed that the effects of the street canyon width on the pedestrian-level wind in a street canyon can be categorized into three different flow regimes. A higher podium creates stronger wind speeds of the flow within the street canyon, and different approaching wind directions change the high-wind-speed zone within the street canyon accordingly.

18 August 2016 in Energies
Verified
Journal Article
Open access
PDF file
PLPin-Feng Liu
Pin-Feng Liu
YLYi-Pin Lin
Yi-Pin Lin
CTChun-Ta Tzeng
Chun-Ta Tzeng
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
This study integrated building material engineering, building construction practices, and heat transfer mechanisms to develop a polyvinyl acetate (PVA) based wall tile, containing macro-encapsulated phase change material (macro-encapsulated PCM, macroPCM) and PVA. The heat transfer characteristics and energy performances of the proposed prototype were investigated experimentally. The results indicated that the PVA-based macroPCM wall tile is suitable for use in exterior walls to enhance the thermal performance. The tile shows a lower heat indoor heat flux than other tested similar building materials and increases the time lag of peak load, effectively shifting the summer peak demand.

13 April 2015 in Energies
Verified
Journal Article
Open access
PDF file
ASAndre Feliks Setiawan
Andre Feliks Setiawan
THTzu-Ling Huang
Tzu-Ling Huang
CTChun-Ta Tzeng
Chun-Ta Tzeng
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
As an emerging country and one of the most populous countries in the world, Indonesia requires a sufficient energy supply to ensure the nation’s continued development. In response to this increasing energy demand, various studies have proposed energy-saving measures; building envelope design is considered to be a typical energy-saving technique. A significant goal in achieving greener buildings is learning how to reduce a building’s energy consumption by applying an efficient energy-saving design. This study used the eQUEST software to investigate how different types of roof construction, glazing and sun-shading techniques affect the energy consumption of residential structures in Indonesia in common scenarios. The results indicate that window shading has the most significant impact on a building’s overall energy consumption, followed by the use of an appropriate glazing, whereas the roof type produced smaller energy efficiency benefits.

30 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
THTzu-Ling Huang
Tzu-Ling Huang
KCKuo Chien-Yuan
Kuo Chien-Yuan
CTChun-Ta Tzeng
Chun-Ta Tzeng
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
The pedestrian wind environment in a street canyon is affected by a multitude of factors, including the height and geometric shape of the surrounding buildings, the street width, the wind direction, and speed. Wind-tunnel tests were performed to determine the effects of constructing high buildings in an urban renewal project in New Taipei City, Taiwan on the pedestrian wind environments in the surrounding street canyons. The results show that replacing the original low-rise buildings with high-rise buildings could decrease the wind speed and natural ventilation potential in certain surrounding street canyons. The flow fields generated by approaching winds in various street canyons are highly complex in this practical case study. Thus, the pedestrian wind patterns in the street canyons cannot be interpreted in terms of channeling and shielding effects alone, as is typically reported in the literature.

17 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
QZQi Zhou
Qi Zhou
PLPin-Feng Liu
Pin-Feng Liu
CTChun-Ta Tzeng
Chun-Ta Tzeng
Chi-Ming LaiChi-Ming Lai
Chi-Ming Lai
This study combines microencapsulated phase change materials (mPCMs) (core material: paraffin; melting points: 37 and 43 °C) and aluminum honeycomb boards (8 mm core cell) to form mPCM roof modules and investigates their heat absorption and release performances, as well as their impact on indoor heat gain by conducting experiments over a 24-h period, subject to representative weather. The outdoor boundary conditions of the module are hourly sunlight and nighttime natural cooling; on the indoor side of the module, the conditions are daytime air conditioning and nighttime natural cooling. The results indicate that compared to a roof module with a 43 °C melting point mPCM, the roof module with a 37 °C melting point mPCM had improved peak load-shifting capacity, but had a slightly increased indoor heat gain. The mPCMs in both roof modules were successfully cooled during the night, returning to their initial state, to begin a new thermal cycle the next day.