Mingke Deng

Prof. Mingke Deng


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2023 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Closed access
PDF file
YZYangxi Zhang
Yangxi Zhang
SZShijun Zhang
Shijun Zhang
TLTong Li
Tong Li
MDMingke Deng
Mingke Deng

25 November 2015 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
MDMingke Deng
Mingke Deng
JHJian Han
Jian Han
HLHaibo Liu
Haibo Liu
MQMeng Qin
Meng Qin
XLXingwen Liang
Xingwen Liang
The compressive toughness evaluation index of HDC (high ductile fiber reinforced concrete) is studied through three groups of uniaxial compressive tests of HDC specimens with different fiber mixing amounts, and an equivalent analysis of their deformability is carried out, coming to the following conclusion:(1)the peak strain of HDC under uniaxial compression can be up to 3.41~3.67 times as large as that of the mortar matrix;(2)the equivalent compressive toughness index reflects the unit volume deformation energy of specimens under uniaxial compression and it can be used as the compressive toughness evaluation index of HDC;(3)the fiber bridging effect of HDC increases the equivalent compressive toughness index and the compressive deformability up to 3 times of the mortar matrix;(4)the relationship between the equivalent compressive toughness indexWcu0.85and the fiber mixing amountφis established according to the test results; and(5)the fiber bridging effect of the matrix in HDC can be equaling as a large number of constraint stirrups installed in the specimens, which significantly enhances the compressive toughness and the compressive deformability of specimens.

1 January 2018 in Advances in Civil Engineering
Verified
Journal Article
Open access
MDMingke Deng
Mingke Deng
JPJiaojiao Pan
Jiaojiao Pan
XLXingwen Liang
Xingwen Liang
It has been widely recognized that the constitutive model plays an essential role in engineering application of high ductile fiber‐reinforced concrete (HDC). In this research, uniaxial compressive tests were conducted on nine groups of HDC specimens with different mixture ratios and one group of mortar matrix specimens as comparison, discussing the effect of fiber content, water‐cement ratio, fly ash content, and sand‐binder ratio. According to the characteristics of stress‐strain curve of HDC under uniaxial compression, a damage constitutive model was proposed by introducing two damage threshold parameters and then was compared with other existing models. Results indicated that the damage model curves suggested in this paper were best consistent with experimental curves and substantially demonstrate the damage evolution process as well as the cracking resistance effect of fiber bridging stress.

15 January 2024 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Closed access
PDF file
JYJiasheng Yang
Jiasheng Yang
MDMingke Deng
Mingke Deng
YZYangxi Zhang
Yangxi Zhang
HFHongkan Fan
Hongkan Fan

23 September 2021 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Closed access
PDF file
MZMin Zhang
Min Zhang
MDMingke Deng
Mingke Deng
ZWZhiyan Wu
Zhiyan Wu
JPJiaojiao Pan
Jiaojiao Pan

1 January 2018 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
MDMingke Deng
Mingke Deng
YZYangxi Zhang
Yangxi Zhang
This study mainly aims to investigate the effectiveness of high‐ductile fiber‐reinforced concrete (HDC) as a means to enhance the seismic performance of short columns. Six HDC short columns and one reinforced concrete (RC) short column were designed and tested under lateral cyclic loading. The influence of the material type (concrete or HDC), axial load, stirrup ratio, and shear span ratio on crack patterns, hysteresis behavior, shear strength, deformation capacity, energy dissipation, and stiffness degradation was presented and discussed, respectively. The test results show that the RC short column failed in brittle shear with poor energy dissipation, while using HDC to replace concrete can effectively improve the seismic behavior of the short columns. Compared with the RC short column, the shear strength of HDC specimens was improved by 12.6–30.2%, and the drift ratio and the energy dissipation increases were 56.9–88.5% and 237.7–336.7%, respectively, at the ultimate displacement. Additionally, the prediction model of the shear strength for RC columns based on GB50010‐2010 (Chinese code) can be safely adopted to evaluate the shear strength of HDC short columns.