Tushar Damle

Dr. Tushar Damle

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
CXChunmeng Xu
Chunmeng Xu
TDTushar Damle
Tushar Damle
MBMatthew Bosworth
Matthew Bosworth
DSDionne Soto
Dionne Soto
RARachit Agarwal
Rachit Agarwal
LGLukas Graber
Lukas Graber
Medium voltage direct current (MVDC) power systems are in their early phase of development, but the lack of efficient and reliable DC circuit breakers is currently one of the most significant bottlenecks for widespread adoption of MVDC applications. Compared to protection devices in high voltage direct current (HVDC) systems, MVDC circuit breakers are expected to interrupt fault currents with higher rates of rise in more power-dense and more controllable structures. A hybrid approach with a piezoelectrically actuated fast mechanical switch in parallel to a solid-state circuit breaker is expected to meet the above requirements. A prototype of a 15 kV-class piezoelectrically actuated fast mechanical switch is presented in this paper. The prototype demonstrates an actuator opening time of 1 ms, a breakdown voltage of over 20 kV, and a continuous current rating of 500 A. After integrating the fast mechanical switch into a hybrid circuit breaker testbed, the fast mechanical switch was able to open within 1.5 ms and the fault was cleared within 5 ms. Therefore, piezoelectrically actuated fast mechanical switches can enable fast, reliable and controllable protection for various MVDC systems like electric ships, electric aircraft and microgrids that integrate distributed energy resources.

28 February 2020 in Transactions on Electrical and Electronic Materials
Verified
Journal Article
Closed access
PDF file
TDTushar Damle
Tushar Damle
MVMichael Varenberg
Michael Varenberg
LGLukas Graber
Lukas Graber

1 August 2017
Verified
Conference Paper
Closed access
MBM. Bosworth
M. Bosworth
DSD. Soto
D. Soto
RAR. Agarwal
R. Agarwal
MSM. Steurer
M. Steurer
TDTushar Damle
Tushar Damle
LGL. Graber
L. Graber
With the future adoption of intermittent sources of power generation and the need for dynamic and reconfigurable power systems, a shift in power system design leans towards power electronics based, fault current limited distribution systems. Design requirements for breakers will focus on fast operation to handle dynamic changes, rather than breaking large magnitude fault currents, as in conventional breakers. High-speed disconnect switches are expected to play a vital role in future DC shipboard power systems. Previous work on an NSF funded project resulted in the development of a 200 A, 15 kV fast mechanical disconnect switch for AC applications. This paper explores the use of the same type of technology for DC power systems, describes the differences and identifies the research and development work needed to make the technology fit for shipboard applications.

1 October 2017
Verified
Conference Paper
Closed access
GLGyu Cheol Lim
Gyu Cheol Lim
TDTushar Damle
Tushar Damle
LGL. Graber
L. Graber
Fast mechanical disconnect switches are an integral part of hybrid circuit breakers, which are proposed as protection devices to clear faults in medium voltage distribution systems. Compared to their conventional counterparts, hybrid circuit breakers can have the ability to limit the fault current, which could allow more interconnections between substations with advantages with respect to grid reliability and resiliency. Furthermore, they enable the integration of distributed generation such as small solar power installations without expensive changes to the grid infrastructure. The proposed design of an ultrafast mechanical disconnect switch operates in vacuum, carries continuous current similar to conventional vacuum interrupters, opens at current zero, features minimum moving mass, and has an open contact separation of less than a millimeter. The limited separation distance requires an optimized contact geometry to keep the electric field within safe limits, minimize the moving mass, and reduce contact resistance. This paper proposes different contact geometries and uses finite element analysis to compare the contact geometries with respect to maximum electric field, mass, and contact resistance. Reductions of mass by 50% and reduction of contact resistance of 10% have been achieved.

3 August 2021
Verified
Conference Paper
Closed access
NGNing Guo
Ning Guo
MLMinuk Lee
Minuk Lee
JCJeong Ho Choi
Jeong Ho Choi
TDTushar Damle
Tushar Damle
LGLukas Graber
Lukas Graber
Medium-voltage direct current (MVDC) distribution systems are proposed for future all-electric ships. For widespread adoption, it is critical to develop creepage distance standards that are applicable for MVDC shipboard power systems. Surface flashover voltage is an important factor affecting the required creepage distance. While the importance of this topic has been recognized for terrestrial HVDC transmission applications, its investigation for MVDC shipboard power systems is in its infancy. This paper studies the characteristics of surface charge distribution along insulators under MVDC stress as well as its impact on the flashover voltage. It is shown that surface charge distribution varies under different voltages. The surface charge accumulated in the middle of the spacer will increase the surface flashover voltage, and with similar profile, the surface flashover voltage will decrease with higher average charge density. Besides average surface charge density, more features of surface charge profile have been found influencing surface flashover voltage.