28 March 2023 in IEEE Transactions on Power Electronics
The dc circuit breaker is an indispensable building block for dc network systems. Hybrid circuit breakers that combine mechanical and solid-state switches have more potential to be utilized in dc distribution networks because of their lower conduction losses and fast interrupt speed. The efficient energy dc interrupter with surge protection (EDISON) removes any solid-state circuit in the main current path, thereby substantially reducing the conduction losses during normal operations. However, it requires a dedicated control with fast dynamics because any false triggering of the mechanical switch or solid-state switches of the breaker would lead to a commutation failure and a potential unquenchable arc. This article proposes an FSM-based control scheme that guarantees the accurate and fast control response during a fault event. Due to this fast response requirement, a dual-core-CPU-based control architecture is applied featuring parallel taskings and negligible communication delays between the two cores. Furthermore, a control-law accelerator is employed to further reduce the latency of the program execution by 33%. The controller hardware-in-the-loop (CHIL) model of the EDISON breaker is implemented in OPAL-RT to verify the control scheme and derisk the prototype test. A fifth-order RLC network is developed to characterize the mechanical switch behavior such that the hybrid circuit model can be simulated in the CHIL solely by circuit components. Finally, the proposed control scheme is implemented and validated in a prototype test with a 3 kA interrupting current and a 60 A/ ${\mu }$ s current commutation rate.
1 June 2022 in IEEE Open Access Journal of Power and Energy
With emerging technologies and products in power semiconductors and ultrafast mechanical switches, direct-current circuit breakers (DCCBs) have been developing rapidly. Yet the metal-oxide varistors (MOVs), being the indispensable DCCB components, are less analyzed and tested so far. Generally, MOVs in DCCBs are used to dissipate energy and limit overvoltage surges during switching events. This emerging application of MOVs calls for new design procedures and evaluation tests to ensure MOV performance under non-standard stresses and repetitive energy pulses. In this paper, online-monitored stress endurance tests are performed on MOVs that are employed in a 12 kV DCCB. Most MOVs have endured the DCCB-derived stresses for about 3500 pulses with little variation in their voltage-current characteristics, while only one fails after 1000 pulse tests and gets damaged by a shunt conductive channel. Different from conventional operating points of MOVs in their voltage-current characteristics, the MOVs in DCCB applications are found to work routinely in the temporary overvoltage (TOV) region with a decreasing TOV current over time. As these behaviors of MOVs are scarcely reported in the literature or covered by their datasheets, this study presents one of the first publicly available endurance test data that address the knowledge gaps about energy-dissipating MOVs in switchgear applications.
13 October 2020 in IEEE Transactions on Power Delivery
Medium voltage direct current (MVDC) power systems are in their early phase of development, but the lack of efficient and reliable DC circuit breakers is currently one of the most significant bottlenecks for widespread adoption of MVDC applications. Compared to protection devices in high voltage direct current (HVDC) systems, MVDC circuit breakers are expected to interrupt fault currents with higher rates of rise in more power-dense and more controllable structures. A hybrid approach with a piezoelectrically actuated fast mechanical switch in parallel to a solid-state circuit breaker is expected to meet the above requirements. A prototype of a 15 kV-class piezoelectrically actuated fast mechanical switch is presented in this paper. The prototype demonstrates an actuator opening time of 1 ms, a breakdown voltage of over 20 kV, and a continuous current rating of 500 A. After integrating the fast mechanical switch into a hybrid circuit breaker testbed, the fast mechanical switch was able to open within 1.5 ms and the fault was cleared within 5 ms. Therefore, piezoelectrically actuated fast mechanical switches can enable fast, reliable and controllable protection for various MVDC systems like electric ships, electric aircraft and microgrids that integrate distributed energy resources.
24 May 2022 in IEEE Transactions on Power Electronics
Varistors are widely used in dc circuit breaker (DCCB) application as fault energy absorption elements, which is not an application the varistors are originally designed for. The fault energy stress adversely impacts the varistor lifetime, thus affecting DCCB reliability and performance. This article presents two methods for choosing the appropriate varistor type and arrangement in a DCCB by linking 1) varistor lifetime and 2) DCCB component- and system-level parameters. The first method uses a set-based design approach with random Latin hypercube sampling to narrow down viable solutions. In comparison, the second method relies on a point-based design approach and proposes an integer programming problem to optimize varistor lifetime. Both procedures are applied to the selection of varistors in 1) a 12 kV DCCB rated for 2-kA nominal current and a peak fault current of 15 kA and 2) a reduced-scale 1.2-kV DCCB hardware prototype, using publicly available varistor data. The article shows the possibility of design for varistor lifetime in DCCB applications, and concludes that both selection procedures provide consistent, reasonable, and verifiable results. However, the results also pinpoint the significant gaps and call for future work on impulse stress versus lifetime relationships for DCCB varistors.
10 June 2024 in IEEE Transactions on Transportation Electrification
The transition to the electric ship requires evolving from passive power regulation to active state anticipation with data linkage and controls between machinery and mission systems to become an agile power and energy system. Toward this, the Navy sponsored research initiatives are currently developing a new Power Electronic Power Distribution System (PEPDS) paradigm. A key enabler for a successful PEPDS research and development (R&D) program is a well-developed and documented functional system architecture as the basis for collaborate research and subsequent future performance studies. The technical approach employs Model-Based Systems Engineering (MBSE) to capture stakeholder needs, behaviors, structures, and measures for PEPDS in a system model. This work has recently re-baselined the functional architecture, which is a solution-independent description of what a system does, defining the trade space for design. It has also explored a point solution for a PEPDS power train and Navy Integrated Power and Energy Corridor (NiPEC) segment and investigated techniques for establishing connections between the System Model and external tools and models. The present paper provides an overview of the process, product, and prospects of that functional architecture, as well as the initial solution space exploration.
18 September 2017 in IEEE Transactions on Power Delivery
When designing utility substations, it is necessary to consider all directional components of the electromagnetic reaction forces during short-circuit faults to properly account for their effects on substation equipment. IEEE 605 assumes straight long parallel conductors in its two-dimensional (2-D) force calculations while ignoring any bends and 3-D placement of conductors. CIGRE's Brochure 105 provides practical information on the mechanical effects of short-circuit currents in HV and EHV open air, conventional substations. Although these computational methods are easy to implement, they have several limitations and are sometimes too conservative. Previously published papers address such conservatism using dynamic analysis approaches that provide more accurate results when compared to experimental data. This paper provides two extensions to IEEE 605 and CIGRE 105 for calculating fault current reaction forces. A closed-form equation defining the simplified 2-D short-circuit force time history during a fault based on CIGRE 105 and a computationally inexpensive numerical 3-D force calculation technique are presented.