John A. Lednicky

Dr. John A. Lednicky

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2019 in Journal of Applied Microbiology
Verified
Journal Article
Open access
PDF file
MPM. Pan
M. Pan
JLJohn A. Lednicky
John A. Lednicky
CWC.‐Y. Wu
C.‐Y. Wu
Viruses that affect humans, animals and plants are often dispersed and transmitted through airborne routes of infection. Due to current technological deficiencies, accurate determination of the presence of airborne viruses is challenging. This shortcoming limits our ability to evaluate the actual threat arising from inhalation or other relevant contact with aerosolized viruses. To improve our understanding of the mechanisms of airborne transmission of viruses, air sampling technologies that can detect the presence of aerosolized viruses, effectively collect them and maintain their viability, and determine their distribution in aerosol particles, are needed. The latest developments in sampling and detection methodologies for airborne viruses, their limitations, factors that can affect their performance and current research needs, are discussed in this review. Much more work is needed on the establishment of standard air sampling methods and their performance requirements. Sampling devices that can collect a wide size range of virus‐containing aerosols and maintain the viability of the collected viruses are needed. Ideally, the devices would be portable and technology‐enabled for on‐the‐spot detection and rapid identification of the viruses. Broad understanding of the airborne transmission of viruses is of seminal importance for the establishment of better infection control strategies.

17 January 2022 in Virology
Verified
Journal Article
Closed access
HXHuanzhou Xu
Huanzhou Xu
IAIbukun A. Akinyemi
Ibukun A. Akinyemi
SCSiddhi A. Chitre
Siddhi A. Chitre
JLJulia C. Loeb
Julia C. Loeb
JLJohn A. Lednicky
John A. Lednicky
SBSumita Bhaduri-McIntosh
Sumita Bhaduri-McIntosh

1 August 2016 in Journal of Clinical Virology
Verified
Journal Article
Closed access
SWSarah K. White
Sarah K. White
WMWenjun Ma
Wenjun Ma
CMClinton J. McDaniel
Clinton J. McDaniel
GGGregory Gray
Gregory Gray
JLJohn A. Lednicky
John A. Lednicky

1 July 2021 in International Journal of Infectious Diseases
Verified
Journal Article
Open access
JLJohn A. Lednicky
John A. Lednicky
MLMichael Lauzardo
Michael Lauzardo
MAM. Alam
M. Alam
MEMaha A. Elbadry
Maha A. Elbadry
CSCaroline J. Stephenson
Caroline J. Stephenson
JMJohn Morris
John Morris
To determine if viable virus could be isolated from the air within a car driven by a patient infected with SARS-CoV-2, and to assess the size range of the infectious particles. We used a Sioutas personal cascade impactor sampler (PCIS) to screen for SARS-CoV-2 in a car driven by a COVID-19 patient. The patient, who had only mild illness without fever or cough and was not wearing a mask, drove the car for 15 min with the air conditioning turned on and windows closed. The PCIS was clipped to the sun-visor above the front passenger seat and was retrieved from the car two hours after completion of the drive. SARS-CoV-2 was detectable at all PCIS stages by PCR and was cultured from the section of the sampler collecting particles in the 0.25–0.50 μm size range. Our data highlight the potential risk of SARS-CoV-2 transmission by minimally symptomatic persons in the closed space inside of a car and suggest that a substantial component of that risk is via aerosolized virus.

10 October 2013 in Influenza Research and Treatment
Verified
Journal Article
Open access
PDF file
JLJohn A. Lednicky
John A. Lednicky
JLJulia C. Loeb
Julia C. Loeb
The air we breathe contains microorganisms that can cause infectious respiratory diseases. After two occupants of an apartment were diagnosed with influenza in February of 2013, efforts were made to detect and isolate airborne influenza virus using two different types of active air samplers: a Sioutas Personal Cascade Impactor Sampler (PCIS) and an SKC BioSampler. The PCIS collects size-fractionated particles by impaction on polytetrafluoroethylene filters, whereas the SKC BioSampler collects airborne particles in liquid media. Influenza H3N2 virus was collected by both types of air samplers. The PCIS collected a range of particle sizes containing influenza virus near one of the sick individuals but only ultrafine particles when the samplers were positioned farther away. Viable virus was present in the liquid collection media of the SKC BioSampler and some PCIS filters. These findings suggest that influenza patients produce ultrafine aerosol particles that contain viable virus.

25 October 2017 in mSphere
Verified
Journal Article
Open access
PDF file
MPMaohua Pan
Maohua Pan
TBTania S. Bonny
Tania S. Bonny
JLJulia Loeb
Julia Loeb
XJXiao Jiang
Xiao Jiang
JLJohn A. Lednicky
John A. Lednicky
CWChang-Yu Wu
Chang-Yu Wu
The dynamics and significance of aerosol transmission of respiratory viruses are still controversial, for the major reasons that virus aerosols are inefficiently collected by commonly used air samplers and that the collected viruses are inactivated by the collection method. Without knowledge of virus viability, infection risk analyses lack accuracy. This pilot study was performed to (i) determine whether infectious (viable) respiratory viruses in aerosols could be collected from air in a real world environment by the viable virus aerosol sampler (VIVAS), (ii) compare and contrast the efficacy of the standard bioaerosol sampler, the BioSampler, with that of the VIVAS for the collection of airborne viruses in a real world environment, and (iii) gain insights for the use of the VIVAS for respiratory virus sampling. The VIVAS operates via a water vapor condensation process to enlarge aerosolized virus particles to facilitate their capture. A variety of viable human respiratory viruses, including influenza A H1N1 and H3N2 viruses and influenza B viruses, were collected by the VIVAS located at least 2 m from seated patients, during a late-onset 2016 influenza virus outbreak. Whereas the BioSampler when operated following our optimized parameters also collected virus aerosols, it was nevertheless overall less successful based on a lower frequency of virus isolation in most cases. This side-by-side comparison highlights some limitations of past studies based on impingement-based sampling, which may have generated false-negative results due to either poor collection efficiency and/or virus inactivation due to the collection process. IMPORTANCE The significance of virus aerosols in the natural transmission of respiratory diseases has been a contentious issue, primarily because it is difficult to collect or sample virus aerosols using currently available air sampling devices. We tested a new air sampler based on water vapor condensation for efficient sampling of viable airborne respiratory viruses in a student health care center as a model of a real world environment. The new sampler outperformed the industry standard device (the SKC BioSampler) in the collection of natural virus aerosols and in maintaining virus viability. These results using the VIVAS indicate that respiratory virus aerosols are more prevalent and potentially pose a greater inhalation biohazard than previously thought. The VIVAS thus appears to be a useful apparatus for microbiology air quality tests related to the detection of viable airborne viruses.