The performance of free-space optics communication (FSOC) is greatly degraded by atmospheric turbulence. Adaptive optics (AO) is an effective method for attenuating the influence. In this paper, the influence of the spatial and temporal characteristics of turbulence on the performance of AO in a FSOC system is investigated. Based on the Greenwood frequency (GF) and the ratio of receiver aperture diameter to atmospheric coherent length (D/r0), the relationship between FSOC performance (CE) and AO parameters (corrected Zernike modes number and bandwidth) is derived for the first time. Then, simulations and experiments are conducted to analyze the influence of AO parameters on FSOC performance under different GF and D/r0. The simulation and experimental results show that, for common turbulence conditions, the number of corrected Zernike modes can be fixed at 35 and the bandwidth of the AO system should be larger than the GF. Measurements of the bit error rate (BER) for moderate turbulence conditions (D/r0 = 10, fG = 60 Hz) show that when the bandwidth is two times that of GF, the average BER is decreased by two orders of magnitude compared with fG/f3dB = 1. These results and conclusions can provide important guidance in the design of an AO system for FSOC.
Fourier ptychographic microscopy (FPM) is a recently developed computational microscopy approach that produces both wide field-of-view (FOV) and high resolution (HR) intensity and a phase image of the sample. Inspired by the ideas of synthetic aperture and phase retrieval, FPM iteratively stitches multiple low-resolution (LR) images with variable illumination angles in Fourier space to reconstruct an HR complex image. Typically, FPM illuminating the sample with an LED array is approximated as a coherent imaging process, and the coherent transfer function (CTF) is imposed as a support constraint in Fourier space. However, a millimeter-scale LED is inapposite to be treated as a coherent light source. As a result, the quality of reconstructed image is degraded by the inappropriate approximation. In this paper, we analyze the coherence of an FPM system and propose a novel constraint approach termed Apodized CTF (AC) constraint in Fourier space. Results on both simulated data and actual captured data show that this new constraint is more stable and robust than CTF. This approach can also relax the coherence requirement of illumination. In addition, it is simple, does not require additional computations, and is easy to be embedded in almost all the reconstruction algorithms proposed so far.
With the rapid development of the virtual reality industry, one of the bottlenecks is the scarcity of video resources. How to capture high-definition panoramic video with depth information and real-time stereo display has become a key technical problem to be solved. In this paper, the optical optimization design scheme of panoramic imaging based on binocular stereo vision is proposed. Combined with the real-time processing algorithm of multi detector mosaic panoramic stereo imaging image, a panoramic stereo real-time imaging system is developed. Firstly, the optical optimization design scheme of panoramic imaging based on binocular stereo vision is proposed, and the space coordinate calibration platform of ultra-high precision panoramic camera based on theodolite angle compensation function is constructed. The projection matrix of adjacent cameras is obtained by solving the imaging principle of binocular stereo vision. Then, a real-time registration algorithm of multi-detector mosaic image and Lucas-Kanade optical flow method based on image segmentation are proposed to realize stereo matching and depth information estimation of panoramic imaging, and the estimation results are analyzed effectively. Experimental results show that the stereo matching time of panoramic imaging is 30 ms, the registration accuracy is 0.1 pixel, the edge information of depth map is clearer, and it can meet the imaging requirements of different lighting conditions.
25 October 2016 in Journal of Physics D: Applied Physics
Holographic polymer dispersed liquid crystal (HPDLC) based distributed feedback (DFB) lasers were prepared with poly (-methoxy-5-(2′-ethyl-hexyloxy)-1,4-phenylene-vinylene) (MEH-PPV) film as the active medium layer. The HPDLC grating film was fabricated via holographic induced photopolymerization. The pure film spectra of MEH-PPV and the amplified spontaneous emission (ASE) spectrum were investigated. The laser device was single-longitudinal mode operation. The tunability of the HPDLC DFB laser was achieved by selecting different grating periods. The lasing performances were also characterized and compared from different diffraction orders. The lasing threshold increased with the diffraction order and the third order laser possessed the largest conversion efficiency in this device. The experimental results were in good agreement with the theoretical calculations.
Fourier ptychographic microscopy (FPM) is a recently developed computational imaging technique that has high-resolution and wide field-of-view (FOV). FPM bypasses the NA limit of the system by stitching a number of variable-illuminated measured images in Fourier space. On the basis of the wide FOV of the low NA objective, the high-resolution image with a wide FOV can be reconstructed through the phase recovery algorithm. However, the high-resolution reconstruction images are affected by the LED array point light source. The results are: (1) the intensities collected by the sample are severely declined when edge LEDs illuminate the sample; (2) the multiple reconstructions are caused by wavevectors inconsistency for the full FOV images. Here, we propose a new lighting scheme termed full FOV Fourier ptychographic microscopy (F3PM). By combining the LED array and telecentric lens, the method can provide plane waves with different angles while maintaining uniform intensity. Benefiting from the telecentric performance and f‒θ property of the telecentric lens, the system stability is improved and the relationship between the position of LED and its illumination angle is simplified. The excellent plane wave provided by the telecentric lens guarantees the same wavevector in the full FOV, and we use this wavevector to reconstruct the full FOV during one time. The area and diameter of the single reconstruction FOV reached 14.6mm2 and 5.4 mm, respectively, and the diameter is very close to the field number (5.5 mm) of the 4× objective. Compared with the traditional FPM, we have increased the diameter of FOV in a single reconstruction by ∼ 10 times, eliminating the complicated steps of computational redundancy and image stitching.
The centroid-based Shack–Hartmann wavefront sensor (SHWFS) treats the sampled wavefronts in the sub-apertures as planes, and the slopes of the sub-wavefronts are used to reconstruct the whole pupil wavefront. The problem is that the centroid method may fail to sense the high-order modes for strong turbulences, decreasing the precision of the whole pupil wavefront reconstruction. To solve this problem, we propose a sub-wavefront estimation method for SHWFS based on the focal plane sensing technique, by which more Zernike modes than the two slopes can be sensed in each sub-aperture. In this paper, the effects on the sub-wavefront estimation method of the related parameters, such as the spot size, the phase offset with its set amplitude and the pixels number in each sub-aperture, are analyzed and these parameters are optimized to achieve high efficiency. After the optimization, open-loop measurement is realized. For the sub-wavefront sensing, we achieve a large linearity range of 3.0 rad RMS for Zernike modes Z2 and Z3, and 2.0 rad RMS for Zernike modes Z4 to Z6 when the pixel number does not exceed 8 × 8 in each sub-aperture. The whole pupil wavefront reconstruction with the modified SHWFS is realized to analyze the improvements brought by the optimized sub-wavefront estimation method. Sixty-five Zernike modes can be reconstructed with a modified SHWFS containing only 7 × 7 sub-apertures, which could reconstruct only 35 modes by the centroid method, and the mean RMS errors of the residual phases are less than 0.2 rad2, which is lower than the 0.35 rad2 by the centroid method.