Wanxu Zhu

Dr. Wanxu Zhu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
WZWanxu Zhu
Wanxu Zhu
HCHongbin Chen
Hongbin Chen
WWWei Wei
Wei Wei
BCBoxuan Chen
Boxuan Chen
XCXuejun Chen
Xuejun Chen
Carbon fiber-reinforced polymer (CFRP) cables are anticipated to be employed in larger, longer, and more durable structures in the engineering field. However, its anchorage devices and mechanism should be appropriately developed and improved. At present, mainly relying on the adhesive force, most anchorage devices may lose their efficiency because of adhesive aging and failure or the slip of an individual tendon. A friction-based composite anchorage device with an integrated bearing of inner cone filler (i.e., load transfer media (LTM)) bonding and a single extruding anchor is proposed, and the anchorage mechanism is examined for Φ7 CFRP cables of strength 2400 MPa. Firstly, sufficient conditions for anti-slip failure of CFRP tendons in the anchorage zone are derived by assuming uniform LTM bonding. The obtained results reveal that the smaller inner pore size of the barrel leads to higher efficiency. Additionally, the maximum efficiency depends on the friction coefficient of the contact surface, the inner cone angle of the barrel, and the diameter and quantity of the CFRP tendons. The necessary conditions for the safety of the CFRP tendon anchorage zone are carefully obtained based on the Tsai–Wu failure criterion. It is concluded that the compressive stress of CFRP tendons in the anchorage zone should gradually increase from the load-bearing end to the no-loading end. Additionally, the relations among the anchorage efficiency coefficient and the CFRP tendon diameter d, the anchorage length l, the dip angle of LTM external conical surface α, and the friction angle β are derived based on the equivalent failure principle. The CFRP cables of four specifications (i.e., with Φ12, Φ19, Φ37, and Φ121 tendons) are designed under theoretical guidance, and eight static tests are carried out for more verification studies. The test results indicate that the anchorage efficiency coefficient of designed anchorage devices can be over 90%, and even up to 96.8%. Further, the failure modes are divergent destruction, which verifies the reliability of friction-based anchorage devices and provides a solid theoretical foundation for the design and engineering applications of CFRP cables.

21 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
WZWanxu Zhu
Wanxu Zhu
WTWei Teng
Wei Teng
FLFengrong Liu
Fengrong Liu
DWDongwen Wu
Dongwen Wu
YWYujiao Wu
Yujiao Wu
The key to evaluating the health status of cable-stayed bridges lies in the accuracy of cable force measurement. When measuring the cable force using the conventional frequency method, the clearance between the bracing cable and the protective tube is typically disregarded. Moreover, due to their large size, existing vibration sensors are difficult to install into protective tubes for steel strand-type bracing cables to measure the cable force. To address the above difficulties, a type of thin rod vibration sensor only 5 mm in diameter was designed based on the high sensitivity of Fiber Bragg grating (FBG), and high-throughput data processing software for engineering calculation (EC) was self-developed. Then, the recognition principle of the thin rod vibration sensor was theoretically analyzed and a step-by-step tension test was carried out. The results demonstrated that the relative error of the cable force measured by the thin rod vibration sensor within 12.865 Hz was less than 5% and the sensitivity reached 28.7 pm/Hz, indicating its high measurement precision. Upon subsequent application of the thin rod vibration sensor to a monitoring test in the field, the relative error of the fundamental frequency between artificial and natural excitations was less than 4%. In addition, the error relative to both the theoretical frequency and the third-party sampling frequency was less than 5%, further verifying the accuracy and applicability for monitoring the cable force of bridges under natural excitation. Compared with the traditional cantilever FBG sensor, the improved sensor with supporting data processing software has the advantages of small cross-section, high reliability, and good sensitivity. The research results can provide a reference for the subsequent accurate measurement of cable force and the development of a supporting sensor data processing system.

12 June 2020 in Strain
Verified
Journal Article
Closed access
PDF file
HQH.Y. Qin
H.Y. Qin
QSQ.X. Shen
Q.X. Shen
WZWanxu Zhu
Wanxu Zhu
HZH.L. Zhang
H.L. Zhang

11 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HZHongmei Zhou
Hongmei Zhou
YZYixiang Zhang
Yixiang Zhang
WZWanxu Zhu
Wanxu Zhu
QZQingyu Zhong
Qingyu Zhong
XHXinyu Huang
Xinyu Huang
During shield construction in underground spaces, synchronous grouting slurry is poured between the surrounding rock and tunnel lining to ensure stability. For synchronous grouting slurries, few studies have investigated the relationship between the rheological parameters and physical properties, grout-segregation mechanism, and anti-segregation performance. Therefore, we explored the relationships between the slurry rheological parameters, segregation rate, and bleeding rate. Cement, sand, fly ash, and bentonite were used to prepare the slurry, and the effects of different polycarboxylate water-reducing agents and dispersible latex powder dosages were studied. The rheological parameters of 16 groups of uniformly designed slurries were tested, and the data were fit using the Herschel–Bulkley model. The optimal mix ratio lowered the slurry segregation rate, and its rheological behaviour was consistent with the Herschel–Bulkley fluid characteristics. High-yield-shear-stress synchronous grouting slurries with high and low viscosity coefficients were less likely to bleed and segregate, respectively. The optimised slurry fluidity, 3 h bleeding rate, 24 h bleeding rate, segregation rate, coagulation time, and 28 days compressive strength were 257.5 mm, 0.71%, 0.36%, 3.1%, 6.7 h, and 2.61 MPa, respectively, which meet the requirements of a synchronous grouting slurry of shield tunnels for sufficiently preventing soil disturbance and deformation in areas surrounding underground construction sites.

22 December 2021 in Marine Georesources & Geotechnology
Verified
Journal Article
Closed access
CWChen Wang
Chen Wang
YYYe Yuan
Ye Yuan
WZWanxu Zhu
Wanxu Zhu
Cao WangCao Wang
Cao Wang
XYXiong Yu
Xiong Yu
Currently, an increasing number of deepwater foundations have been built in marine regions, and most of them have to deal with scour problems. Recent design codes of superstructures usually adopt the probability-based method, in which loads are treated as probabilistic parameters. However, for the design of substructures, the impact of scour is generally regarded as a deterministic value represented by the estimated scour depth. This inconsistency in the design strategies brings difficulties in considering the uncertainties associated with scour effects. Fundamentally, this is due to the challenges in the scour estimation using a probabilistic method. Based on an augmented scour database analyzed using the artificial neural-network (ANN), this study quantifies the uncertainties of four types of scour predictive methods. Based on this, it proposes a probabilistic approach for scour estimation according to different cases. Six typical conditions and two practical cases were analyzed using the probabilistic approach. The overall reliability index showed that all these existing scour estimation methods have certain limitations, including inconsistent reliability and unreliable scour depth predictions. To prevent these problems, a concept based on the probability of nonexceedance of a given scour depth has been proposed, which was determined by different target reliability requirements.

27 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
WZWanxu Zhu
Wanxu Zhu
WWWei Wei
Wei Wei
FLFengrong Liu
Fengrong Liu
RZRong Zeng
Rong Zeng
The cables of high-strength carbon fiber reinforced polymer (CFRP) plates are starting to be applied to large spatial structures. However, their main anchorage systems rely on the adhesive force, which entails risks to their integrity resulting from aging of the binding agent. In this study, a friction-based wedge anchorage system was designed for CFRP plates. The working mechanism of the proposed anchorage system was explored both theoretically and experimentally. The anti-slip mechanism and condition of CFRP plates were formulated so that the equivalent frictional angle of the contact surface between a CFRP plate and wedges must not be smaller than the sum of the dip angle of the wedge external conical surface and the frictional angle between the wedges and barrel. An analysis of the stress distribution in the anchorage zone of the CFRP plate was conducted using the Tsai-Wu failure criterion, which concluded that the compressive stresses should be reduced on the section closer to the load-bearing end of the anchorage system. Furthermore, the anchorage efficiency coefficient was proposed, which depends on stress concentration coefficients, plate thickness, length of anchorage zone, dip angle of wedge external conical surface, and its frictional angle. Then, it was determined that the minimum length of an anchorage zone for the CFRP plates with various specifications should be at least 49 times larger than the CFRP thickness. A finite element analysis and static tensile tests on six specimens were carried out. The experimental results revealed that the anchorage efficiency coefficient of the optimized anchor reached 97.9%.