Background/Objectives: Fluoroscopy has been widely adopted in interventional pulmonology, as it facilitates real-time visualization of the bronchoscope, endobronchial ultrasound, and biopsy tools during procedures. The purpose of this study was to evaluate the effectiveness of radiation shields in minimizing scattered X-ray dose to the bronchoscopist in a phantom study and to determine the dose of scattered X-ray dose to medical staff with radiation shields in clinical application. Methods: An anthropomorphic torso phantom was positioned on the fluoroscopic table between the C-arm X-ray tube and the image detector to mimic bronchoscopic operations. Upper and lower body lead shields were used to examine the effectiveness of radiation shielding. Scatter radiation rates were assessed at a first operator location using real-time dosimeters with and without protective devices. In clinical application, the scattered X-ray dose of the first operator and main assistant was measured using wearable radiation dosimeters during 20 procedures. Results: In the phantom study, scattered radiation without shielding was 266.34 ± 8.86 μSv/h (glabella), 483.90 ± 8.01 μSv/h (upper thorax), 143.97 ± 8.20 μSv/h (hypogastrium), and 7.22 ± 0.28 μSv/h (ankle). The combination of upper and lower body lead shields reduced the scattered X-ray dose by 98.7%, 98.3%, 66.2%, and 79.9% at these levels, respectively. In clinical application, mean scattered X-ray dose rates were 0.14 ± 0.05 μSv/procedure (eye), 0.46 ± 0.51 μSv/procedure (chest), 0.67 ± 0.50 μSv/procedure (hypogastrium), and 1.57 ± 2.84 μSv/procedure (assistant’s wrist). Conclusions: The combination of radiation shields significantly reduced the scattered X-ray dose at the operator site in the phantom study. The scattered X-ray dose to medical staff during bronchoscopy can be kept at a low level with the aid of a shielding system.
There is no validated clinical biomarker for disease severity or treatment response for nontuberculous mycobacterial pulmonary disease (NTM-PD). We investigated the correlation between elevated serum carbohydrate antigen (CA) 19-9 levels and NTM-PD disease activity, defined using an imaging severity score based on chest computed tomography (CT). We retrospectively examined 79 patients with NTM-PD who underwent serum CA19-9 level assessments and chest CT less than 1 month apart. NTM-PD severity was rated using a CT-based scoring system. The correlation between the CT score and serum CA19-9 levels was evaluated. Chest CT revealed nodular bronchiectasis without cavitation in most patients (78.5%). Serum CA19-9 levels were elevated in 19 (24%) patients. Serum CA19-9 levels were positively correlated with the total CT score and bronchiectasis, bronchiolitis, cavity, and consolidation subscores. Partial correlation analysis revealed a significant positive correlation between serum CA19-9 levels and CT scores for total score and bronchiectasis, bronchiolitis, cavitation, and consolidation subscores after controlling for age, sex, and BMI. Serum CA19-9 levels were positively correlated with the CT severity score for NTM-PD. Serum CA19-9 may be useful in evaluating disease activity or therapeutic response in patients with NTM-PD.
1 January 2024 in Journal of Korean Medical Science