Hosang Jeon

Dr. Hosang Jeon

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
YKYongkan Ki
Yongkan Ki
WKWontaek Kim
Wontaek Kim
YKYong Ho Kim
Yong Ho Kim
DKDonghyun Kim
Donghyun Kim
JBJin Sook Bae
Jin Sook Bae
JNJiho Nam
Jiho Nam
Ki Y, et al. J Korean Med Sci. 2017 May;32(5):757-763. https://doi.org/10.3346/jkms.2017.32.5.757

12 September 2012 in Orthodontics & Craniofacial Research
Verified
Journal Article
Closed access
PDF file
HJHosang Jeon
Hosang Jeon
SLS. J. Lee
S. J. Lee
TKTae-Woo Kim
Tae-Woo Kim
RDR. E. Donatelli
R. E. Donatelli

20 March 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HJHosang Jeon
Hosang Jeon
DKDong Woon Kim
Dong Woon Kim
JJJi Hyeon Joo
Ji Hyeon Joo
YKYongkan Ki
Yongkan Ki
SKSuk-Woong Kang
Suk-Woong Kang
HSHEE YUN SEOL
HEE YUN SEOL
Background/Objectives: Fluoroscopy has been widely adopted in interventional pulmonology, as it facilitates real-time visualization of the bronchoscope, endobronchial ultrasound, and biopsy tools during procedures. The purpose of this study was to evaluate the effectiveness of radiation shields in minimizing scattered X-ray dose to the bronchoscopist in a phantom study and to determine the dose of scattered X-ray dose to medical staff with radiation shields in clinical application. Methods: An anthropomorphic torso phantom was positioned on the fluoroscopic table between the C-arm X-ray tube and the image detector to mimic bronchoscopic operations. Upper and lower body lead shields were used to examine the effectiveness of radiation shielding. Scatter radiation rates were assessed at a first operator location using real-time dosimeters with and without protective devices. In clinical application, the scattered X-ray dose of the first operator and main assistant was measured using wearable radiation dosimeters during 20 procedures. Results: In the phantom study, scattered radiation without shielding was 266.34 ± 8.86 μSv/h (glabella), 483.90 ± 8.01 μSv/h (upper thorax), 143.97 ± 8.20 μSv/h (hypogastrium), and 7.22 ± 0.28 μSv/h (ankle). The combination of upper and lower body lead shields reduced the scattered X-ray dose by 98.7%, 98.3%, 66.2%, and 79.9% at these levels, respectively. In clinical application, mean scattered X-ray dose rates were 0.14 ± 0.05 μSv/procedure (eye), 0.46 ± 0.51 μSv/procedure (chest), 0.67 ± 0.50 μSv/procedure (hypogastrium), and 1.57 ± 2.84 μSv/procedure (assistant’s wrist). Conclusions: The combination of radiation shields significantly reduced the scattered X-ray dose at the operator site in the phantom study. The scattered X-ray dose to medical staff during bronchoscopy can be kept at a low level with the aid of a shielding system.

1 June 2009 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
HJHosang Jeon
Hosang Jeon
HKHyunduk Kim
Hyunduk Kim
BCBo Kyung Cha
Bo Kyung Cha
JKJong Yul Kim
Jong Yul Kim
GCGyuseong Cho
Gyuseong Cho
Jong-Il YunJong-Il Yun
Jong-Il Yun

28 July 2015 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
HJHosang Jeon
Hosang Jeon
MCMyung Jin Chung
Myung Jin Chung
SYSeungman Youn
Seungman Youn
JNJiho Nam
Jiho Nam
JLJayoung Lee
Jayoung Lee
HKHo Kyung Kim
Ho Kyung Kim
One of the emerging issues in radiography is low-dose imaging to minimize patient’s exposure. The scintillating materials employed in most indirect flat-panel detectors show a drastic change of X-ray photon absorption efficiency around their K-edge energies that consequently affects image quality. Using various tube voltages, we investigated the imaging performance of most popular scintillators: cesium iodide (CsI) and gadolinium oxysulfide (Gd2O2S). The integrated detective quantum efficiencies (iDQE) of four detectors installed in the same hospital were evaluated according to the standardized procedure IEC 62220-1 at tube voltages of 40 - 120 kVp. The iDQE values of the Gd2O2S detectors were normalized by those of CsI detectors to exclude the effects of image postprocessing. The contrast-to-noise ratios (CNR) were also evaluated by using an anthropomorphic chest phantom. The iDQE of the CsI detector outperformed that of the Gd2O2S detector over all tube voltages. Moreover, we noted that the iDQE of the Gd2O2S detectors quickly rolled off with decreasing tube voltage under 70 kVp. The CNRs of the two scintillators were similar at 120 kVp. At 60 kVp, however, the CNR of Gd2O2S was about half that of CsI. Compared to the Gd2O2S detectors, variations in the DQE performance of the CsI detectors were relatively immune to variations in the applied tube voltages. Therefore, we claim that Gd2O2S detectors are inappropriate for use in low-tube-voltage imaging (e.g., extremities and pediatrics) with low patient exposure.

18 March 2015
Verified
Conference Paper
Closed access
PDF file
HYHanbean Youn
Hanbean Youn
HKHo Kyung Kim
Ho Kyung Kim
SKSoohwa Kam
Soohwa Kam
SKSeung Hyun Kim
Seung Hyun Kim
JPJi-Woong Park
Ji-Woong Park
HJHosang Jeon
Hosang Jeon
We present a theoretical framework describing projections obtained from computed tomography systems considering physics of each component consisting of the systems. The projection model mainly consists of the attenuation of x-ray photons through objects including x-ray scatter and the detection of attenuated/scattered x-ray photons at pixel detector arrays. X-ray photons are attenuated by the Beers-Lambert law and scattered by using the Klein-Nishina formula. The cascaded signal-transfer model for the detector includes x-ray photon detection and light photon conversion/spreading in scintillators, light photon detection in photodiodes, and the addition of electronic noise quanta. On the other hand, image noise is considered by re-distributing the pixel signals in pixel-by-pixel ways at each image formation stage using the proper distribution functions. Instead of iterating the ray tracing over each energy bin in the x-ray spectrum, we first perform the ray tracing for an object only considering the thickness of each component. Then, we assign energy-dependent linear attenuation coefficients to each component in the projected images. This approach reduces the computation time by a factor of the number of energy bins in the x-ray spectrum divided by the number of components in the object compared with the conventional ray-tracing method. All the methods developed in this study are validated in comparisons with the measurements or the Monte Carlo simulations.