Analysis consisting of numerical simulations along with lab experiments of interaction effects between key parameters on the electromagnetic force based on response surface methodology (RSM) has been also proposed to optimize the design of high-speed solenoid valve (HSV) and improve its performance. Numerical simulation model of HSV has been developed in Ansoft Maxwell environment and its accuracy has been validated through lab experiments. Effect of change of core structure, coil structure, armature structure, working air gap, and drive current on the electromagnetic force of HSV has been analyzed through simulation model and influence rules of various parameters on the electromagnetic force have been established. The response surface model of the electromagnetic force has been utilized to analyze the interaction effect between major parameters. It has been concluded that six interaction factors including working air gap with armature radius, drive current with armature thickness, coil turns with side pole radius, armature thickness with its radius, armature thickness with side pole radius, and armature radius with side pole radius have significant influence on the electromagnetic force. Optimal match values between coil turns and side pole radius; armature thickness and side pole radius; and armature radius and side pole radius have also been determined.
1 January 2017 in Mathematical Problems in Engineering
A novel formula easily applied with high precision is proposed in this paper to fit the B‐H curve of soft magnetic materials, and it is validated by comparison with predicted and experimental results. It can accurately describe the nonlinear magnetization process and magnetic saturation characteristics of soft magnetic materials. Based on the electromagnetic transient coupling principle, an electromagnetic mathematical model of a high‐speed solenoid valve (HSV) is developed in Fortran language that takes the saturation phenomena of the electromagnetic force into consideration. The accuracy of the model is validated by the comparison of the simulated and experimental static electromagnetic forces. Through experiment, it is concluded that the increase of the drive current is conducive to improving the electromagnetic energy conversion efficiency of the HSV at a low drive current, but it has little effect at a high drive current. Through simulation, it is discovered that the electromagnetic energy conversion characteristics of the HSV are affected by the drive current and the total reluctance, consisting of the gap reluctance and the reluctance of the iron core and armature soft magnetic materials. These two influence factors, within the scope of the different drive currents, have different contribution rates to the electromagnetic energy conversion efficiency.
To alleviate the Eddy effect of the high-speed solenoid valve (HSV) and improve its dynamic response speed, a novel HSV with a composite iron core is presented. The time-step finite element method is used to establish and verify the numerical simulation of HSV coupling multiple physical fields. Then, the Eddy effect and dynamic response characteristics of the conventional and composite HSVs are further compared and analyzed. The results showed that the Eddy current loss in the main pole was the largest for the conventional HSV, accounting for 72.5% and 64.4% in the actuation and release processes, respectively. It was found that the Eddy effect of the composite HSV was obviously weakened, and the total Eddy current losses in the actuation and release processes were reduced by 58.8% and 38.7%, respectively. Meanwhile, the actuation response time and release response time of the composite HSV were shortened by 15.6% and 18.5%, respectively. In addition, increasing the peak voltage further shortened the actuation response time of the composite HSV, but had no significant effect on the response time of the conventional HSV.
22 January 2020 in Mathematical Problems in Engineering
A 3D numerical simulation model of high-speed solenoid valve (HSV) for electronic control fuel injection system (ECFIS) has been developed. The model has been validated experimentally with acceptable maximum errors of 2% and 8.7% in closure response time and open response time, respectively. Effect of assembly parameters such as residual air gap, maximum lift of valve stem, mass of the moving parts, spring stiffness, and spring pretightening force on dynamic response characteristics of HSV has been analyzed in detail using the simulation model, and influence rules of various parameters on dynamic response characteristics have been established. Moreover, the correlation between interaction factors of main influence factors and dynamic response characteristics of HSV has also been analyzed. It is concluded that residual air gap, maximum lift of the valve stem, and spring pretightening force are the main influencing factors on dynamic response characteristics of HSV, and there are obvious interaction effects between them; when two or three of these main influencing factors are adjusted at the same time, the interaction effects should be considered.
In this study, the performance of a long-stroke moving-iron proportional solenoid actuator (MPSA) was improved by combining numerical simulations and experiments. A finite element model of the MPSA was developed; its maximum and mean relative absolute errors of electromagnetic force were 4.3% and 2.3%, respectively, under typical work conditions. Seven design parameters including the cone angle, cone length, depth of the inner hole of the coil skeleton, cone width of the armature, inner cone diameter, and initial position of the moving-iron core were selected for developing the model, and the coefficient of the variation in electromagnetic force, nominal acceleration, 95% of the maximum stable output electromagnetic force, and corresponding response time were used as the performance indicators. The constraint relation between each performance indicator and the influence of each design parameter on the performance indicators were revealed using the uniform Latin hypercube experiment design, correlation analysis, and the main effect analysis method. A multi-objective optimization mathematical model of the MPSA was developed by combining traditional surrogate and machine learning models. The Pareto solution set was obtained using the nondominated sorting genetic algorithm II (NSGA-II), and three decision schemes with different attitudes were determined using the Hurwicz multi-criteria decision-making method. The results showed that a strong contradiction exists among the 95% of the maximum stable output electromagnetic force and its corresponding response time and the coefficient of the variation in electromagnetic force. The cone angle considerably influenced the performance indicators. Compared with the initial design, the coefficient of the variation in electromagnetic force was reduced by 54.08% for the positive decision, the corresponding response time was shortened by 15.65% for the critical decision, and the corresponding acceleration was enhanced by 10.32% for the passive decision. Thus, the overall performance of the long-stroke MPSA effectively improved.
12 September 2022 in IEEE Transactions on Industrial Electronics
To improve the precision of the magnetostatic finite element model for the long-stroke moving-iron proportional electromagnetic actuator, on the basis of three characteristic parameters, including the initial relative permeability of materials μ r , saturation magnetic polarization J S and knee point adjustment coefficient of magnetizing curve a , this paper puts forward an efficient demarcation method by virtually remodeling the magnetizing curve of soft magnetic material for the actuator and combining surrogate model and optimization technique. Then, the demarcation mathematical models based on surrogate model are built while taking μ r , J S and a of the soft magnetic material 1 for the main magnetic loop of the actuator as calibration parameters, and regarding the Relative Root Mean Square Error and Relative Maximum Absolute Error of electromagnetic force under the typical operating conditions of the actuator as targets. Finally, the demarcation mathematical models are solved by Downhill Simplex Method and the final calibration parameters are confirmed. The results indicate that the Relative Root Mean Square Error , Relative Maximum Absolute Error and Relative Average Absolute Error of finite element model after demarcation are 2.7%, 4.3% and 2.3%, respectively, decreasing of 57.1%, 58.7% and 39.5% with respect to the initial finite element model of the actuator.