Suat Saribas

Dr. Suat Saribas

Department of Medical Microbiology, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, 34098 Istanbul, Fatih, Turkey
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Journal of Medical Microbiology
Verified
Journal Article
Closed access
BKBekir Kocazeybek
Bekir Kocazeybek
MSMerve Kutlu Sakli
Merve Kutlu Sakli
PYPelin Yuksel
Pelin Yuksel
Mehmet DemirciMehmet Demirci
Mehmet Demirci
RCReyhan Caliskan
Reyhan Caliskan
HThrisi bahar tokman
hrisi bahar tokman
Purpose. We aimed to investigate the presence of three recently identified point mutations (A2115G, G2141A and A2144T) of the 23 S rRNA gene and compare them with the three most frequently encountered point mutations (A2142G, A2142C and A2143G) in Helicobacter pylori strains in Turkey. Methodology. A total of 63 patients (mean 47.08±12.27) were included. The E-test method (for clarithromycin) was used for the clarithromycin antimicrobial susceptibility test of isolated H. pylori strains. Real-time PCR was used to detect the point mutations. Results. A total of 24 out of 63 H. pylori strains (38.1%) were detected as clarithromycin resistant (>0.5 mg l−1 ). The new A2115G (n:6, 25%), A2144T (n:7, 29.1%) and G2141A, 8 (n:8, 33.3%) mutations and the classical A2142G (n:8, 33.3%) and A2143G (n:11, 45.8%) point mutations were detected in the 24 clarithromycin-resistant strains. The A2144T point mutation had the highest median MIC value (3 mg l−1 ) amongst the new mutations, but the classical mutations (A2142G and A2143G) had the highest median MIC values (256 mg l−1 ) overall. The presence of the A2115G (OR:31.66), A2144T (OR:36.92) or G2141A (OR:28.16) mutations increased the likelihood of clarithromycin resistance in H. pylori strains by 31.66-, 36.92- and 28.16-fold (ORs), respectively, according to the binary logistic regression analysis. Conclusion. We concluded that classical mutations of the 23 S rRNA gene resulted in higher clarithromycin MIC values than new mutations. These new point mutations caused moderate elevations in the MIC values of clarithromycin-resistant H. pylori strains.

31 March 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HUHayriye Kırkoyun Uysal
Hayriye Kırkoyun Uysal
PSPari Sohrabi
Pari Sohrabi
ZHZafer Habip
Zafer Habip
SSSuat Saribas
Suat Saribas
EKEmre Kocazeybek
Emre Kocazeybek
BKBekir Kocazeybek
Bekir Kocazeybek
We aimed to evaluate the roles of the plasma immune activation biomarkers neopterin and soluble CD14 (sCD14) in the indirect assessment of the immune activation status of patients with the indeterminate HIV-1 (IHIV-1) pattern and a true HIV-1-positive infection (PCG). This cross-sectional and descriptive study included eighty-eight patients with the IHIV-1 pattern, 100 patients in the PCG, and 100 people in a healthy control group (HCG). Neopterin and sCD14 levels were determined by competitive and sandwich ELISA methods, respectively. Mean neopterin and sCD14 levels among those with the IHIV-1 pattern were significantly lower than among the PCG (p < 0.001 and p = 0.001, respectively), but they were similiar to those in the HCG (p = 0.57 and p = 0.66, respectively. Mean neopterin and sCD14 levels among the PCG were found to be significantly higher than among those with the IHIV-1 pattern (p < 0.001 and p = 0.001, respectively) and among those in the HCG (p = 0.001, p < 0.001, respectively). Neopterin did not have adequate predictive value for identifying those in the PCG (area under the curve [AUC] = 0.534; 95% CI, 0.463–0.605; p = 0.4256); sCD14 also had poor predictive value but high specificity (100%) for identifying those in the PCG (AUC = 0.627; 95% CI, 0.556–0.694; p = 0.0036). While low levels of these two biomarkers were detected among those with the IHIV-1 pattern, they were found in high levels among those in the PCG. These two markers obviously cannot be used as a sceening test because they have low sensitivies. Taken together, we suggest that neopterin and sCD14 may be helpful because they both have high specificity (92%-100%) as indirect non-specific markers for predicting the immune activation status of individuals, whether or not they have true positive HIV-1.

1 December 2012 in Transfusion and Apheresis Science
Verified
Journal Article
Closed access
SISena Izmirli
Sena Izmirli
DCDeniz Gozde Celik
Deniz Gozde Celik
PYPelin Yuksel
Pelin Yuksel
SSSuat Saribas
Suat Saribas
MAMustafa Aslan
Mustafa Aslan
BKBekir Kocazeybek
Bekir Kocazeybek

5 April 2022 in Balkan Medical Journal
Verified
Journal Article
Open access
HDHarika Öykü Dinç
Harika Öykü Dinç
Mehmet DemirciMehmet Demirci
Mehmet Demirci
YOYusuf Emre Ozdemir
Yusuf Emre Ozdemir
Serhat SirekbasanSerhat Sirekbasan
Serhat Sirekbasan
AAAyse Nur Aktaş
Ayse Nur Aktaş
BKBekir Kocazeybek
Bekir Kocazeybek
Background: Monitoring the longevity of immunoglobulin G (IgG) responses following severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infections is vital to understanding the role of antibodies in preventing infection. Aims: To determine the quantitative IgG responses specific to the Spike-S1 (S1) receptor-binding domain (S1/RBD) region of the virus in serum samples taken between 4 weeks and 7 months after polymerase chain reaction (PCR) positivity in patients who are diagnosed with coronavirus disease-2019 (COVID-19). Study Design: A longitudinal study. Methods: This study included 113 patients with a clinical and molecular diagnosis of COVID-19. The first and second serum samples were taken 1 and 7 months, respectively, after the PCR positivity. S1/ RBD-specific IgG antibody response was assayed using anti-SARS-CoV-2 QuantiVac ELISA (IgG) kit (Euroimmun, Lubeck, Germany). The neutralizing antibodies were investigated in 57 patients whose IgG test results were above the cut-off value. Results: In 57 patients with SARS-CoV-2 IgG, the anti-SARS-CoV-2 IgG quantitative antibody levels significantly decreased after 7 months (Z = -2.197, p = 0.028). A correlation was detected between the anti-SARS-CoV-2 IgG and nAb percent inhibition (IH%) levels detected in 1 month (rs = 0.496, p < 0.001), but without significant correlation in serum samples taken on 7 months. The nAb IH% levels of the first and second were compared for COVID-19 severity and revealed no statistical difference (p = 0.256). In the second serum sample, the nAb IH%s of patients with moderate COVID-19 showed a statistically significant difference from patients with mild COVID-19 (p = 0.018), but without significant differences between severe and moderate or mild COVID-19. Conclusion: SARS-CoV-2 quantitative IgG antibody titers are significantly reduced at long-term follow-up (> 6 months). Due to the limited information on seroconversion, comprehensive studies should be conducted for long-term follow-up of the immune response against SARS-CoV-2.

1 September 2015 in Romanian Journal of Legal Medicine
Verified
Journal Article
Closed access
HCH. Cakan
H. Cakan
KGK. Güven
K. Güven
FCF.E. Cevik
F.E. Cevik
Mehmet DemirciMehmet Demirci
Mehmet Demirci
SSSuat Saribas
Suat Saribas

1 July 2010
Verified
Journal Article
Closed access
TZTevhide Ziver
Tevhide Ziver
PYPelin Yuksel
Pelin Yuksel
GIGokhan Ipek
Gokhan Ipek
IYIbrahim Yekeler
Ibrahim Yekeler
ZBZehra Bayramoglu
Zehra Bayramoglu
BKBekir Kocazeybek
Bekir Kocazeybek