Yaman Hamed

Mr. Yaman Hamed


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Alexandria Engineering Journal
Verified
Journal Article
Open access
YHYaman Hamed
Yaman Hamed
AAAhmed Ibrahim Alzahrani
Ahmed Ibrahim Alzahrani
ASA'FZa Shafie
A'FZa Shafie
ZMZahiraniza Mustaffa
Zahiraniza Mustaffa
MIMokhtar Che Ismail
Mokhtar Che Ismail
KEKee Kok Eng
Kee Kok Eng

1 September 2017 in Journal of Cleaner Production
Verified
Journal Article
Closed access
MAMohamad Sahban Alnarabiji
Mohamad Sahban Alnarabiji
NYNoorhana Yahya
Noorhana Yahya
YHYaman Hamed
Yaman Hamed
SASeyed Esmaeil Mahdavi Ardakani
Seyed Esmaeil Mahdavi Ardakani
KAKhairun Azizi
Khairun Azizi
ONOmar Nashed
Omar Nashed


5 September 2016
Verified
Conference Paper
Closed access
YHYaman Hamed
Yaman Hamed
ASA'FZa Shafie
A'FZa Shafie
ZMZahiraniza Bt Mustaffa
Zahiraniza Bt Mustaffa
NINaila Rusma Binti Idris
Naila Rusma Binti Idris
Every measuring equipment or inspection tool is known to have its own accuracy, which may affect the reliability of its measurements. This affects Oil and Gas pipeline corrosion measurements, which may affect data reliability if not well interpreted. The inspection tolerance occurred in the measurements should be treated carefully for each equipment to prevented misinterpretation of the data which could lead to incorrect assessment. This paper presents a new application of K-Nearest Neighbor interpolation to calibrate corrosion measurements collected by Magnetic Flux Leakage intelligent pig (MFL-IP) with the readings of Ultrasonic Testing (UT) scan device. The final enhanced metrics will be used in the integrity assessment report of the pipeline to decide whether the pipeline is fit for service or needs certain maintenance.

28 November 2018 in Measurement and Control
Verified
Journal Article
Open access
YHYaman Hamed
Yaman Hamed
ASA’fZa Shafie
A’fZa Shafie
ZMZahiraniza Mustaffa
Zahiraniza Mustaffa
NRNaila Rusma
Naila Rusma
Inline inspection tools that are used to scan the interior defects of gas and oil pipelines tend to suffer from measuring error due to their sizing accuracy. This error often causes an over- or under-estimation of the operating conditions of the pipeline, which might lead to a system failure. While parametric calibration models provide a simple method to reduce the measuring error, it is limited to datasets that follow the normal distribution only. Thus, in this paper, a non-parametric calibration model based on k-nearest neighbor interpolation was proposed to improve the measurements recorded by the scanning tools. Corrosion data collected using an ultrasonic scan device and the magnetic flux leakage intelligent pig are considered in the research. The k-nearest neighbor interpolation is studied based on the effect of using six kernel functions with two different positioning approaches on the interpolation behavior. The results have shown enhancement in the accuracy of the readings obtained from the intelligent pig from ±20% of the pipeline wall thickness to only ±8%. This enhancement in the sizing accuracy is meant to prevent a possible system failure for using the corroded part of the studied pipeline for an extra 4.6 years instead of replacing it.

11 April 2016 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
YHYaman Hamed
Yaman Hamed
ASA’fza Shafie
A’fza Shafie
ZMZahiraniza Bt Mustaffa
Zahiraniza Bt Mustaffa
NINaila Rusma Binti Idris
Naila Rusma Binti Idris
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry