The choice of an impression material for a particular situation depends on the treatment being provided, operator preference, and so on. Even with the introduction of more advanced and more accurate rubber base impression materials, irreversible hydrocolloid impression materials have stood the test of time. This article gives a detailed perspective of how best to make alginate impressions.
5 February 2013 in The Journal of Indian Prosthodontic Society
Dental technology is undergoing advancements at a fast pace and technology is being imported from various other fields. One such imported technology is direct metal laser sintering technology for casting metal crowns. This article will discuss the process of laser sintering for making metal crowns and fixed partial dentures with a understanding of their pros and cons.
Dental pulp treatment is the least intrusive procedure currently available for preserving the vitality of the pulp. Several studies are underway to improve the bioactivity of pulp capping materials. Tideglusib isa potent anti-inflammatory, antioxidant, and a regenerative drug developed against Alzheimer’s disease and has been shown to be effective in the treatment of dental cavities. However, its bioactive properties encapsulated within the nanoparticles as a component of pulp capping material are largely unknown. In this study, tideglusib-loaded bioactive glass nanoparticles were synthesized (tideglusib-BgNPs) and mixed at various concentrations into the calcium silicate cement to testits physiomechanical and bioactivitiescompared with biodentine (control). The calcium silicate cement with 10wgt% tideglusib-BgNPs showed comparable physiomechanical properties to that of biodentine. Additionally, the assessment of cytotoxicity and bioactivity (cell proliferation, wound healing, and cell migration assays) showed increased bioactivity in terms of better wound healing, increased proliferation, and better migration of human dental pulp stem cells than biodentine. These findings suggest new opportunities to use tideglusib-BgNPs in pulp therapy.
9 August 2021 in The Journal of Contemporary Dental Practice
To compare and evaluate the mechanical properties of 2.5% titanium dioxide nanoparticle (TiO2 NP) incorporated as filler in an experimental composite resin with everX Flow and MultiCore Flow. TiO2 was prepared and incorporated into experimental dental composite resin. The experimental and traditional composite resin was grouped as follows: Group I: The experimental composite resin with 2.5% of TiO2 fillers, Group II: everX Flow (GC EUROPE), and Group III: MultiCore Flow (Ivoclar Vivadent). Based on International Standards Organization (ISO) 4049, the samples were prepared for the compressive, diametral tensile, and flexural test. Statistical analysis was done, and the results were tabulated. Compared to the other tested materials, the experimental composite resin had relatively high compressive strength, diametral tensile strength, and flexural strength. Compared to MultiCore Flow, the everX Flow showed strong mechanical properties. Based on the result of the study, it can be concluded that the 2.5% TiO2 NP incorporated as filler in an experimental composite resin demonstrated higher mechanical properties compared to the conventional material. The unique photoactivities of TiO2 NP and their superior mechanical properties make them one of the ideal additives to enhance the performance of polymeric materials.
5 June 2021 in Journal of Pharmacy and Bioallied Sciences
Background: Peri implant infection in dental implantology is a frequently encountered clinical problem. Titania nanotubes (TNTs) are recent improvement in surface characterization, showing promising results. Aim: The nanosurface parameter tweaking has been implicated with profound change in the microbiological and biological response. Hence, it was proposed that alteration in the nanotube diameter could have positive influence in its antibacterial activity against salient periodontal pathogens. Materials and Methods: Commercially, pure titanium discs of 8-mm diameter and 1.5-mm thickness were prepared. Polished titanium discs were used as control (Group A). Vertically oriented, structured TNTs were fabricated by anodization technique and grouped as B and C, having nanotube diameter, 40 and 80 nm subsequently. The surface characterizations of the samples were done by scanning electron microscope analysis. The antibacterial activity was evaluated with the bacterial colony counting method, at 24 h, 72 h, and 1-week intervals. Statistical Analysis: The one-way analysis of variance and Tukey's honest significance post hoc test were employed to assess the statistical significance. Results: The 80 nm nanotubes showed better antibacterial activity comparatively, at all three-time intervals investigated. Conclusion: The optimal TNT diameter of 80 nm was the most effective from an antimicrobial stand point of view.
This study analyzes the evidence of the marginal discrepancy and internal adaptation of copings fabricated using three types of resin patterns with subtractive (milling) and additive technology (3D printing), as it is not widely reported. Working casts (n = 15) were scanned and patterns were completed using computer-aided designing (CAD). Resin patterns were fabricated using the designed data and divided into three groups according to the method of fabrication of patterns: subtractive technology–CAD milled polymethyl methacrylate resin (Group-PMMA), additive technology [digital light processing (DLP) technique]–acrylonitrile–butadiene–styrene (ABS) patterns (Group-ABS), and polylactic acid (PLA) patterns (Group-PLA). Resin patterns were casted with Cobalt–Chromium (Co–Cr) alloy (lost wax technique). Internal and marginal gaps of the metal copings were analyzed with the replica technique under optical microscope. The Kruskal–Wallis test was used to compare values among the groups, and post hoc multiple tests confirmed the specific differences within the groups. The median marginal gap was least for CAD milled resin patterns, followed by PLA printed resin patterns and ABS printed resin patterns. There were significant differences between Group-PMMA and Group-PLA and Group-ABS (p = 0.0001). There was no significant difference between Group-PLA and Group-ABS (p = 0.899). The median internal gap was least for metal copings fabricated from Group-PLA, followed by Group-ABS and Group-PMMA. The differences were not statistically significant (p = 0.638) for the internal gap. Full metal Co–Cr copings fabricated from the milled PMMA group had a better marginal fit, followed by the PLA and ABS printed groups. Copings fabricated with the PLA printed group had the best internal fit, though the values were statistically insignificant between the groups.