Vicente Pons-Beltrán

Vicente Pons-Beltrán


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2007 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
VPVicente Pons-Beltrán
Vicente Pons-Beltrán
PNPilar Nos
Pilar Nos
GBGuillermo Bastida
Guillermo Bastida
BBBelén Beltran
Belén Beltran
LALidia Argüello
Lidia Argüello
TSTeresa Sala
Teresa Sala

10 April 2011 in Digestive Diseases and Sciences
Verified
Journal Article
Closed access
PDF file
VPVicente Pons-Beltrán
Vicente Pons-Beltrán
BSBegoña González Suárez
Begoña González Suárez
CACecilia González Asanza
Cecilia González Asanza
EPEnrique Pérez-Cuadrado
Enrique Pérez-Cuadrado
SDServando Fernández Diez
Servando Fernández Diez
PFPedro Menchen Fernández-Pacheco
Pedro Menchen Fernández-Pacheco

3 October 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
AFAlejandro Fornes-Leal
Alejandro Fornes-Leal
CGC Garcia-Pardo
C Garcia-Pardo
MFM Frasson
M Frasson
VPVicente Pons-Beltrán
Vicente Pons-Beltrán
NCN Cardona
N Cardona
Several reports over the last few decades have shown that the dielectric properties of healthy and malignant tissues of the same body organ usually show different values. However, no intensive dielectric studies of human colon tissue have been performed, despite colon cancer’s being one of the most common types of cancer in the world. In order to provide information regarding this matter, a dielectric characterization of healthy and malignant colon tissues is presented. Measurements are performed on ex vivo surgery samples obtained from 20 patients, using an open-ended coaxial probe in the 0.5–18 GHz frequency band. Results show that the dielectric constant of colon cancerous tissue is 8.8% higher than that of healthy tissues ( p = 0.002). Besides, conductivity is about 10.6% higher, but in this case measurements do not have statistical significance ( p = 0.038). Performing an analysis per patient, the differences in dielectric constant between healthy and malignant tissues appear systematically. Particularized results for specific frequencies (500 MHz, 900 MHz, 2.45 GHz, 5 GHz, 8.5 GHz and 15 GHz) are also reported. The findings have potential application in early-stage cancer detection and diagnosis, and can be useful in developing new tools for hyperthermia treatments as well as creating electromagnetic models of healthy and cancerous tissues.

20 May 2019 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
MBMartina Barbi
Martina Barbi
CGConcepcion Garcia-Pardo
Concepcion Garcia-Pardo
ANAndrea Nevarez
Andrea Nevarez
VPVicente Pons-Beltrán
Vicente Pons-Beltrán
NCNarcis Cardona
Narcis Cardona
In recent years, localization for capsule endoscopy applications using Ultra-Wideband (UWB) technology has become an attractive field of investigation due to its potential benefits for patients. Literature concerning performance analysis of RF-based localization techniques for in-body applications at UWB frequencies is very limited. Available studies mainly rely on Finite Difference Time Domain (FDTD) simulations, using digital human models and on experimental measurements by means of homogeneous phantoms. Nevertheless, no realistic analysis based on multilayer phantom measurements or through in vivo experiment has been reported yet. This paper investigates the performance of RSS-based approach for two-dimensional (2D) and three-dimensional localization (3D) in the UWB frequency band. For 2D localization, experimental laboratory measurements using a two-layer phantom based setup have been conducted. For 3D localization, data from a recently conducted in vivo experiment have been used. Localization accuracy using path loss (PL) models, under ideal and not ideal channel estimation assumptions, are compared. Results show that under not ideal channel assumption the relative localization error slightly increases for the 2D case but not for the in vivo 3D case. Impact of receivers selection on the localization accuracy has also been investigated for both, 2D and 3D, cases.

26 April 2023 in Gut
Verified
Journal Article
Closed access
PDF file
PLPedro López-Muñoz
Pedro López-Muñoz
RMRubén Martín-Cabezuelo
Rubén Martín-Cabezuelo
VLVicente Lorenzo-Zuniga
Vicente Lorenzo-Zuniga
Guillermo Vilariño-FeltrerGuillermo Vilariño-Feltrer
Guillermo Vilariño-Feltrer
ITIsabel Tort-Ausina
Isabel Tort-Ausina
VPVicente Pons-Beltrán
Vicente Pons-Beltrán
Objectives: GI endoscopy units represent the third largest producers of medical waste. We aimed to determine endoscopic instrument composition and life cycle assessment (LCA) and to assess a sustainability proposal based on a mark on the instruments that identifies parts can be safely recycled or ‘ green mark ’. Design: Material composition analysis and LCA of forceps, snares and clips from four different manufacturers (A–D) were performed with four different methods. Carbon footprint from production, transportation and end of life of these instruments was calculated. In 30 consecutive procedures, we marked the contact point with the working channel. 5 cm away from that point was considered as green mark . One-week prospective study was conducted with 184 procedures evaluating 143 instruments (75 forceps, 49 snares and 19 haemoclips) to assess the efficacy of this recyclable mark. Results: Composition from different manufacturers varied widely. Most common materials were high global warming potential (GWP) waste (polyethylene, polypropylene and acrylonitrile) and low GWP waste (stainless steel). Significant differences were found for the forceps (0.31–0.47 kg of CO 2 equivalent (CO 2 -eq)) and haemoclips (0.41–0.57 kg CO 2 -eq) between the manufacturers. Green mark was established 131.26 cm for gastroscope and 195.32 cm for colonoscope. One-week activity produced 67.74 kg CO 2 -eq. Applying our sustainability intervention, we could reduce up to 27.44% (18.26 kg CO 2 -eq). This allows the recycling of 61.7% of the instrument total weight (4.69 kg). Conclusion: Knowledge of carbon footprint is crucial to select the most sustainable alternatives because there are large variations between brands. A mark to identify recyclable parts could reduce our environmental impact significantly.

1 January 2017 in World Journal of Gastroenterology
Verified
Journal Article
Open access
MLMarisol Luján-Sanchis
Marisol Luján-Sanchis
EPEnrique Perez-Cuadrado-Robles
Enrique Perez-Cuadrado-Robles
JGJavier García-Lledó
Javier García-Lledó
JFJosé-Francisco Juanmartiñena Fernández
José-Francisco Juanmartiñena Fernández
Luca ElliLuca Elli
Luca Elli
JSJavier Sempere-García-Argüelles
Javier Sempere-García-Argüelles
To analyze the diagnostic yield (DY), therapeutic impact (TI) and safety of capsule endoscopy (CE). This is a multi-centre, observational, analytical, retrospective study. A total of 163 patients with suspicion of celiac disease (CD) (mean age = 46.4 ± 17.3 years, 68.1% women) who underwent CE from 2003 to 2015 were included. Patients were divided into four groups: seronegative CD with atrophy (Group-I, n = 19), seropositive CD without atrophy (Group-II, n = 39), contraindication to gastroscopy (Group-III, n = 6), seronegative CD without atrophy, but with a compatible context (Group-IV, n = 99). DY, TI and the safety of CE were analysed. The overall DY was 54% and the final diagnosis was villous atrophy (n = 65, 39.9%), complicated CD (n = 12, 7.4%) and other enteropathies (n = 11, 6.8%; 8 Crohn’s). DY for groups I to IV was 73.7%, 69.2%, 50% and 44.4%, respectively. Atrophy was located in duodenum in 24 cases (36.9%), diffuse in 19 (29.2%), jejunal in 11 (16.9%), and patchy in 10 cases (15.4%). Factors associated with a greater DY were positive serology (68.3% vs 49.2%, P = 0.034) and older age (P = 0.008). On the other hand, neither sex nor clinical presentation, family background, positive histology or HLA status were associated with DY. CE results changed the therapeutic approach in 71.8% of the cases. Atrophy was associated with a greater TI (92.3% vs 45.3%, P < 0.001) and 81.9% of the patients responded to diet. There was one case of capsule retention (0.6%). Agreement between CE findings and subsequent histology was 100% for diagnosing normal/other conditions, 70% for suspected CD and 50% for complicated CD. CE has a high DY in cases of suspicion of CD and it leads to changes in the clinical course of the disease. CE is safe procedure with a high degree of concordance with histology and it helps in the differential diagnosis of CD.