Elia Landi

Dr. Elia Landi

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GRGabriele Di Renzone
Gabriele Di Renzone
ELElia Landi
Elia Landi
Marco MugnainiMarco Mugnaini
Marco Mugnaini
LPLorenzo Parri
Lorenzo Parri
Giacomo PeruzziGiacomo Peruzzi
Giacomo Peruzzi
Alessandro PozzebonAlessandro Pozzebon
Alessandro Pozzebon
Within the big picture of the Internet of Things (IoT) a brand new paradigm has risen since few years ago in the context of industrial scenarios: the Industrial Internet of Things (IIoT), whose aim is to transplant all of the features, characteristics and scopes of the IoT into industrial settings. The latter ones might be subject to a wide range of environmental conditions from the point of view of both temperature and relative humidity, along with harmful gases exposure and vibration due to, for instance, machineries. Therefore, whenever their monitoring is performed by means of devoted infrastructures, such extreme working conditions must be born in mind during the pertaining design phases. Mostly, industrial monitoring is put into effect by resorting to wireless sensor networks enabled by Low Power Wide Area Network (LPWAN) techonologies. This set of facilities includes an ample heterogeneity of standards and techniques. However, the Long Range (LoRa) modulation and the LoRa Wide Area Network (LoRaWAN) protocol extensively proved to be reliable and robust alternatives. Thus, in this paper the variations of hardware performances of a LoRaWAN sensor node, in terms of transmission capabilities, due to the changes of temperature and relative humidity, vibration and gaseous atmospheres like CO, NO and NO2, which are typical of industrial processes, are investigated. In so doing, an ageing process due to the aforementioned phenomena was induced. To this end, a measurement campaign within controlled environments (i.e., a climatic chamber, a fume extraction plant and an adhoc vibration test bench) was sorted out, whose results show a physiological performances drop that neither undermine the network reliability, nor damage the sensor node electronics.

25 February 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Ada FortAda Fort
Ada Fort
ELElia Landi
Elia Landi
AGAnna Lo Grasso
Anna Lo Grasso
Marco MugnainiMarco Mugnaini
Marco Mugnaini
Enza PanzardiEnza Panzardi
Enza Panzardi
VVValerio Vignoli
Valerio Vignoli
The paper provides an overview of the measurement issues affecting sensing systems based on QCM, operating in liquid. The paper analyses the effect of the presence of a viscous liquid at the interface with the QCM sensors by analytical models and experimental tests based on impedance measurements in reference conditions. The study takes also into account the parasitic effects due to the measurement setup and provides results, which can be applied to a wide range of scenarios also in the presence of highly viscous media. The paper also presents a model fitting procedure for QCM impedance spectra, which provides accurate estimations of the electromechanical parameters.

20 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Ada FortAda Fort
Ada Fort
Enza PanzardiEnza Panzardi
Enza Panzardi
VVValerio Vignoli
Valerio Vignoli
MTMarco Tani
Marco Tani
ELElia Landi
Elia Landi
PVPietro Vaccarella
Pietro Vaccarella
In this paper, a novel measurement system based on Quartz Crystal Microbalances is presented. The proposed solution was conceived specifically to overcome the measurement problems related to Quartz Crystal Microbalance (QCM) applications in dielectric liquids where the Q-factor of the resonant system is severely reduced with respect to in-gas applications. The QCM is placed in a Meacham oscillator embedding an amplifier with adjustable gain, an automatic strategy for gain tuning allows for maintaining the oscillator frequency close to the series resonance frequency of the quartz, which is related in a simple way with the physical parameters of interest. The proposed system can be used to monitor simultaneously both the series resonant frequency and the equivalent electromechanical resistance of the quartz. The feasibility and the performance of the proposed method are proven by means of measurements obtained with a prototype based on a 10-MHz AT-cut quartz.

31 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TATommaso Addabbo
Tommaso Addabbo
Ada FortAda Fort
Ada Fort
ELElia Landi
Elia Landi
RMRiccardo Moretti
Riccardo Moretti
Marco MugnainiMarco Mugnaini
Marco Mugnaini
VVValerio Vignoli
Valerio Vignoli
In this paper, an FPGA (Field Programmable Gate Array)-based digital architecture for the measurement of quartz crystal microbalance (QCM) oscillating frequency of transient responses, i.e., in QCM-D (QCM and Dissipation) applications, is presented. The measurement system is conceived for operations in liquid, with short QCM transient responses due to the large mechanical load. The proposed solution allows for avoiding the complex processing systems typically required by the QCM-D techniques and grants frequency resolutions better than 1 ppm. The core of the architecture is a reciprocal digital frequency meter, combined with the preprocessing of the QCM signal through mixing operations, such as a step-down of the input frequency and reducing the measurement error. The measurement error is further reduced through averaging. Different strategies are proposed to implement the proposed measurement solution, comprising an all-digital circuit and mixed analog/digital ones. The performance of the proposed architectures is theoretically derived, compared, and analyzed by means of experimental data obtained considering 10 MHz QCMs and 200 μs long transient responses. A frequency resolution of about 240 ppb, which corresponds to a Sauerbrey mass resolution of 8 ng/cm2, is obtained for the all-digital solution, whereas for the mixed solution the resolution halves to 120 ppb, with a measurement time of about one second over 100 repetitions.

25 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
LPLorenzo Parri
Lorenzo Parri
MTMarco Tani
Marco Tani
DBDavid Baldo
David Baldo
SPStefano Parrino
Stefano Parrino
ELElia Landi
Elia Landi
Ada FortAda Fort
Ada Fort
The safety of an operator working in a hazardous environment is a recurring topic in the technical literature of recent years, especially for high-risk environments such as oil and gas plants, refineries, gas depots, or chemical industries. One of the highest risk factors is constituted by the presence of gaseous substances such as toxic compounds such as carbon monoxide and nitric oxides, particulate matter or indoors, in closed spaces, low oxygen concentration atmospheres, and high concentrations of CO2 that can represent a risk for human health. In this context, there exist many monitoring systems for lots of specific applications where gas detection is required. In this paper, the authors present a distributed sensing system based on commercial sensors aimed at monitoring the presence of toxic compounds generated by a melting furnace with the aim of reliably detecting the insurgence of dangerous conditions for workers. The system is composed of two different sensor nodes and a gas analyzer, and it exploits commercial low-cost commercially available sensors.

5 November 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Ada FortAda Fort
Ada Fort
ELElia Landi
Elia Landi
Marco MugnainiMarco Mugnaini
Marco Mugnaini
LPLorenzo Parri
Lorenzo Parri
Alessandro PozzebonAlessandro Pozzebon
Alessandro Pozzebon
VVValerio Vignoli
Valerio Vignoli
Gases emitted by domestic and industrial boilers significantly contribute to the overall pollution levels of urban environments. Among these gases, Carbon Monoxide (CO) represents a marker of the efficiency of the combustion processes, and the monitoring of its emissions, even if often neglected, is crucial to improve the energy efficiency and the environmental safety within a Smart City context. This paper aims at describing a real-time, remote system for the monitoring of CO emissions of domestic and industrial boilers, based on the use of a low power Long Range Wide Area Network (LoRaWAN) sensor node. In particular, the proposed solution is based on an ad-hoc frontend circuit acting as a power gating system for the rest of the sensor node, exploiting the output of the CO sensor as a trigger to activate the data acquisition and transmission module. Such a solution allows to notably increase the life time of the node, allowing its powering by means of rechargeable Li-Ion batteries. Tests were performed on a real boiler in order to demonstrate the validity of the proposed solution. Power consumption of the sensor node was experimentally measured: theoretical analysis demonstrated an ideal life time for the sensor node up to 2 years and half.