Eoghan Dunne

Dr. Eoghan Dunne

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EDEoghan Dunne
Eoghan Dunne
ASAdam Santorelli
Adam Santorelli
BMBrian McGinley
Brian McGinley
GLGeraldine Leader
Geraldine Leader
MOMartin O’hAlloran
Martin O’hAlloran
Emily PorterEmily Porter
Emily Porter
Urinary Incontinence affects over 200 million people worldwide, severely impacting the quality of life of individuals. Bladder state detection technology has the potential to improve the lives of people with urinary incontinence by alerting the user before voiding occurs. To this end, the objective of this study is to investigate the feasibility of using supervised machine learning classifiers to determine the bladder state of ‘full’ or ‘not full’ from electrical impedance measurements. Electrical impedance data was obtained from computational models and a realistic experimental pelvic phantom. Multiple datasets with increasing complexity were formed for varying noise levels in simulation. 10-Fold testing was performed on each dataset to classify ‘full’ and ‘not full’ bladder states, including phantom measurement data. Support vector machines and k-Nearest-Neighbours classifiers were compared in terms of accuracy, sensitivity, and specificity. The minimum and maximum accuracies across all datasets were 73.16% and 100%, respectively. Factors that contributed most to misclassification were the noise level and bladder volumes near the threshold of ‘full’ or ‘not full’. This paper represents the first study to use machine learning for bladder state detection with electrical impedance measurements. The results show promise for impedance-based bladder state detection to support those living with urinary incontinence.

Verified
Journal Article
Open access
PDF file
JBJara M. Baena-Montes
Jara M. Baena-Montes
TOTony O'Halloran
Tony O'Halloran
CCCormac Clarke
Cormac Clarke
KDKevin Donaghey
Kevin Donaghey
EDEoghan Dunne
Eoghan Dunne
LQLeo Quinlan
Leo Quinlan
Cardiac ablation with irreversible electroporation (IRE) is quickly being established as a modality of choice for atrial fibrillation treatment. While it has not yet been optimised, IRE has the potential to significantly limit collateral damage and improve cell-specific targeting associated with other energy sources. However, more tissue and cell-specific evidence is required to demonstrate the selective threshold parameters for human cells. The aim here is to determine the optimal ablation threshold parameters related to lesion size for human cardiomyocytes in 2D culture. Conventional biphasic pulses of different field strengths and on-times were delivered in a monolayer culture system of human AC16 cardiomyocytes. The dynamics of cell death and lesion dimensions were examined at different time points. Human cardiomyocytes are susceptible to significant electroporation and cell death at a field strength of 750 V/cm or higher with 100 μs pulses. Increasing the IRE on-time from 3 ms to 60 ms reduces the effective field threshold to 250 V/cm. Using very short pulses of 2 μs and 5 μs also causes significant cell death, but only at fields higher than 1000 V/cm. A longer on-time results in more cell death and induced greater lesion area in 2D models. In addition, different forms of cell death are predicted based on the evolution of cell death over time. This study presents important findings on the ability of different IRE parameters to induce human cardiomyocyte cell death. Lesion size can be tuned by appropriate choice of IRE parameters and cardiomyocytes display an upregulation of delayed cell death 24 h after electroporation, which is an important consideration for clinical practice.

1 December 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
EDEoghan Dunne
Eoghan Dunne
ASAdam Santorelli
Adam Santorelli
BGBrian Mc Ginley
Brian Mc Ginley
GLGeraldine Leader
Geraldine Leader
MOMartin O’HAlloran
Martin O’HAlloran
Emily PorterEmily Porter
Emily Porter
Objective : In this study, we examine the potential of using machine learning classification to determine the bladder state (‘not full’, ‘full’) with electrical impedance tomography (EIT) images of the pelvic region. Accurate classification of these states would enable urinary incontinence (UI) monitoring to alert the patient, before involuntary voiding occurs, in a low-cost and discrete manner. Approach : Using both numerical and experimental data, we form datasets that contain diverse observations with varying clinical parameters such as bladder volume, urine conductivity, and the reference used for time-difference imaging. We then classify the bladder state using both pixel-wise and feature extraction-based classification techniques. We employ principal component analysis, wavelets, and image segmentation to help create features. Main results : The performance was compared across several classifier algorithms. The minimum accuracy was 77.50%. The highest accuracy observed was 100%, and was found by combining principal component analysis and the Gaussian radial based function kernel support vector machine. This combination also offered the best trade-off between classification performance and the costs of training time and memory space. The biggest challenge in bladder state classification is classifying volumes near the separation volume of not full and full, in which choosing the most suitable classifier combination can minimize this error. Significance : We performed the first machine learning classification of bladder EIT images, achieving high classification accuracies with both numerical and experimental data. This work highlights the potential of using image-based machine learning with an EIT device to support bladder monitoring for those suffering from UI.

1 March 2018 in Physiological Measurement
Verified
Journal Article
Open access
EDEoghan Dunne
Eoghan Dunne
BMBrian McGinley
Brian McGinley
MOMartin O’HAlloran
Martin O’HAlloran
Emily PorterEmily Porter
Emily Porter
Objective : To design and fabricate an anatomically and conductively accurate phantom for electrical impedance studies of non-invasive bladder volume monitoring. Approach : A modular pelvic phantom was designed and fabricated, consisting of a mechanically and conductively stable boundary wall, a background medium, and bladder phantoms. The wall and bladders are made of conductive polyurethane. The background material is an ultrasound gel-based mixture, with conductivity matched to a weighted average of the pelvic cavity organs, bone, muscle and fat. The phantom boundary is developed using a computer tomography model of a male human pelvis. The bladder phantoms were designed to correlate with human bladder dimensions. Electrical impedance measurements of the phantom were recorded, and images produced using six different bladder phantoms and a realistic finite element model. Main results : Five different bladder volumes were successfully imaged using an empty bladder as a reference. The average conductivity index from the reconstructed images showed a strong positive correlation with the bladder phantom volumes. Significance : A conductively and anatomically accurate pelvic phantom was developed for non-invasive bladder volume monitoring using electrical impedance measurements. Several bladders were designed to correlate with actual human bladder volumes, allowing for accurate volume estimation. The conductivity of the phantom is accurate over 50–250 kHz. This phantom can allow changeable electrode location, contact and size; multi-layer electrodes configurations; increased complexity by addition of other organ or bone phantoms; and electrode movement and deformation. Overall, the pelvic phantom enables greater scope for experimentation and system refinement as a precursor to in-man clinical studies.

30 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Nuno P. SilvaNuno P. Silva
Nuno P. Silva
Bilal AminBilal Amin
Bilal Amin
EDEoghan Dunne
Eoghan Dunne
NHNiamh Hynes
Niamh Hynes
MOMartin Ohalloran
Martin Ohalloran
AEAdnan Elahi
Adnan Elahi
Over the past two decades, there has been extensive research into surveillance methods for the post-endovascular repair of abdominal aortic aneurysms, highlighting the importance of these technologies in supplementing or even replacing conventional image-screening modalities. This review aims to provide an overview of the current status of alternative surveillance solutions for endovascular aneurysm repair, while also identifying potential aneurysm features that could be used to develop novel monitoring technologies. It offers a comprehensive review of these recent clinical advances, comparing new and standard clinical practices. After introducing the clinical understanding of abdominal aortic aneurysms and exploring current treatment procedures, the paper discusses the current surveillance methods for endovascular repair, contrasting them with recent pressure-sensing technologies. The literature on three commercial pressure-sensing devices for post-endovascular repair surveillance is analyzed. Various pre-clinical and clinical studies assessing the safety and efficacy of these devices are reviewed, providing a comparative summary of their outcomes. The review of the results from pre-clinical and clinical studies suggests a consistent trend of decreased blood pressure in the excluded aneurysm sac post-repair. However, despite successful pressure readings from the aneurysm sac, no strong link has been established to translate these measurements into the presence or absence of endoleaks. Furthermore, the results do not allow for a conclusive determination of ongoing aneurysm sac growth. Consequently, a strong clinical need persists for monitoring endoleaks and aneurysm growth following endovascular repair.

14 December 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
EDEoghan Dunne
Eoghan Dunne
MOMartin O'HAlloran
Martin O'HAlloran
DCDarren Craven
Darren Craven
PPPrem Puri
Prem Puri
PFPaul Frehill
Paul Frehill
Emily PorterEmily Porter
Emily Porter
Objective: The purpose of this study is to detect vesicoureteral reflux (VUR) noninvasively using an electrical impedance tomography (EIT). VUR is characterized by the backflow of urine from the bladder to the kidneys. Methods: Using porcine models, small quantities of a solution mimicking the electrical properties of urine were infused into each ureter. EIT measurements were taken before, during and after the infusion using electrodes positioned around the abdomen. The collected data from 116 experiments were then processed and time-difference images reconstructed. Objective VUR detection was determined through statistical analysis of the mean change in the voltage signals and EIT image pixel intensities. Results: Unilateral VUR was successfully detected in 94.83% of all mean voltage signals and in over 98.28% of the reconstructed images. The images showed strong visual contrast between the region of interest and the background. Conclusion: In animal models, EIT has the capability to detect reflux in the kidneys with high accuracy. The results show promise for EIT to be used for screening of VUR in children. Significance: VUR is the most common congenital urinary tract abnormality in children. The condition predisposes children to urinary tract infections and kidney damage. The current gold standard diagnostic test, a voiding cystourethrogram, is invasive and uses ionizing radiation; therefore, there is a need for new tools for identifying VUR in children. This study presents a noninvasive method to detect VUR in animal models, illustrating the potential for EIT as a screening tool in clinical scenarios.