Nuno P. Silva

Mr. Nuno P. Silva

National University of Ireland Galway
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Nuno P. SilvaNuno P. Silva
Nuno P. Silva
ABAnna Bottiglieri
Anna Bottiglieri
Raquel ConceiçãoRaquel Conceição
Raquel Conceição
MOMartin Ohalloran
Martin Ohalloran
Laura FarinaLaura Farina
Laura Farina
Electromagnetic-based hyperthermic therapies induce a controlled increase of temperature in a specific tissue target in order to increase the tissue perfusion or metabolism, or even to induce cell necrosis. These therapies require accurate knowledge of dielectric and thermal properties to optimise treatment plans. While dielectric properties have been well investigated, only a few studies have been conducted with the aim of understanding the changes of thermal properties as a function of temperature; i.e., thermal conductivity, volumetric heat capacity and thermal diffusivity. In this study, we experimentally investigate the thermal properties of ex vivo ovine liver in the hyperthermic temperature range, from 25 °C to 97 °C. A significant increase in thermal properties is observed only above 90 °C. An analytical model is developed to model the thermal properties as a function of temperature. Thermal properties are also investigated during the natural cooling of the heated tissue. A reversible phenomenon of the thermal properties is observed; during the cooling, thermal properties followed the same behaviour observed in the heating process. Additionally, tissue density and water content are evaluated at different temperatures. Density does not change with temperature; mass and volume losses change proportionally due to water vaporisation. A 30% water loss was observed above 90 °C.

1 March 2020
Verified
Conference Paper
Closed access
Nuno P. SilvaNuno P. Silva
Nuno P. Silva
ABAnna Bottiglieri
Anna Bottiglieri
Raquel ConceiçãoRaquel Conceição
Raquel Conceição
MOMartin O'Halloran
Martin O'Halloran
LFLaura Farina
Laura Farina

30 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Nuno P. SilvaNuno P. Silva
Nuno P. Silva
Bilal AminBilal Amin
Bilal Amin
EDEoghan Dunne
Eoghan Dunne
NHNiamh Hynes
Niamh Hynes
MOMartin Ohalloran
Martin Ohalloran
AEAdnan Elahi
Adnan Elahi
Over the past two decades, there has been extensive research into surveillance methods for the post-endovascular repair of abdominal aortic aneurysms, highlighting the importance of these technologies in supplementing or even replacing conventional image-screening modalities. This review aims to provide an overview of the current status of alternative surveillance solutions for endovascular aneurysm repair, while also identifying potential aneurysm features that could be used to develop novel monitoring technologies. It offers a comprehensive review of these recent clinical advances, comparing new and standard clinical practices. After introducing the clinical understanding of abdominal aortic aneurysms and exploring current treatment procedures, the paper discusses the current surveillance methods for endovascular repair, contrasting them with recent pressure-sensing technologies. The literature on three commercial pressure-sensing devices for post-endovascular repair surveillance is analyzed. Various pre-clinical and clinical studies assessing the safety and efficacy of these devices are reviewed, providing a comparative summary of their outcomes. The review of the results from pre-clinical and clinical studies suggests a consistent trend of decreased blood pressure in the excluded aneurysm sac post-repair. However, despite successful pressure readings from the aneurysm sac, no strong link has been established to translate these measurements into the presence or absence of endoleaks. Furthermore, the results do not allow for a conclusive determination of ongoing aneurysm sac growth. Consequently, a strong clinical need persists for monitoring endoleaks and aneurysm growth following endovascular repair.

17 May 2023 in International Journal of Hyperthermia
Verified
Journal Article
Open access
MLMattia De Lazzari
Mattia De Lazzari
ASAnna Ström
Anna Ström
Laura FarinaLaura Farina
Laura Farina
Nuno P. SilvaNuno P. Silva
Nuno P. Silva
Sergio CurtoSergio Curto
Sergio Curto
HTHana Dobsicek Trefna
Hana Dobsicek Trefna
Phantoms accurately mimicking the electromagnetic and thermal properties of human tissues are essential for the development, characterization, and quality assurance (QA) of clinically used equipment for Hyperthermia Treatment (HT). Currently, a viable recipe for a fat equivalent phantom is not available, mainly due to challenges in the fabrication process and fast deterioration. We propose to employ a glycerol-in-oil emulsion stabilized with ethylcellulose to develop a fat-mimicking material. The dielectric, rheological, and thermal properties of the phantom have been assessed by state-of-the-art measurement techniques. The full-size phantom was then verified in compliance with QA guidelines for superficial HT, both numerically and experimentally, considering the properties variability. Dielectric and thermal properties were proven equivalent to fat tissue, with an acceptable variability, in the 8 MHz to 1 GHz range. The rheology measurements highlighted enhanced mechanical stability over a large temperature range. Both numerical and experimental evaluations proved the suitability of the phantom for QA procedures. The impact of the dielectric property variations on the temperature distribution has been numerically proven to be limited (around 5%), even if higher for capacitive devices (up to 20%). The proposed fat-mimicking phantom is a good candidate for hyperthermia technology assessment processes, adequately representing both dielectric and thermal properties of the human fat tissue while maintaining structural stability even at elevated temperatures. However, further experimental investigations on capacitive heating devices are necessary to better assess the impact of the low electrical conductivity values on the thermal distribution.

30 November 2020
Verified
Book Chapter
Closed access
PDF file
Nuno P. SilvaNuno P. Silva
Nuno P. Silva
ABAnna Bottiglieri
Anna Bottiglieri
EPEmily Porter
Emily Porter
MOMartin O’hAlloran
Martin O’hAlloran
LFLaura Farina
Laura Farina

7 October 2024 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
Nuno P. SilvaNuno P. Silva
Nuno P. Silva
BABilal Amin
Bilal Amin
EDEoghan Dunne
Eoghan Dunne
MOMartin O’hAlloran
Martin O’hAlloran
AEAdnan Elahi
Adnan Elahi