Purpose: To investigate the impact of corneal higher-order aberrations (HOAs) on predicted corrected distance visual acuity (CDVA) in patients with keratoconus at varying simulated pupil apertures. Setting: Ophthalmology Clinics, Medical University of South Carolina, Charleston, South Carolina. Design: Retrospective chart review study. Methods: 56 eyes with keratoconus were examined using Scheimpflug tomography during routine examinations before medical intervention. The severity of keratoconus was graded using the Amsler-Krumeich classification. Zernike analysis was used to obtain corneal aberrations using simulated pupil diameters of 6 mm, 4 mm, and 2 mm. These data were extrapolated to obtain the total root mean square HOAs for a 1.6 mm simulated pupil to evaluate the potential effect of a small aperture intraocular lens (IOL). Correlation analysis was used to study the impact and relative contributions of HOAs on CDVA. Convolution of HOAs from OPD-Scan III provided a clinical method to predict CDVA with different simulated pupil sizes in corneas with irregular astigmatism. Results: There were statistically significant positive correlations between photopic CDVA and the magnitude of total and individual (coma, spherical aberration, and trefoil) HOAs in this cohort of keratoconus participants. A keratoconus case with the small aperture IOL confirms the improvement in vision due to the pinhole effect. Conclusions: The small aperture IOL is expected to markedly reduce aberrations in patients with keratoconus up to Amsler-Krumeich class 4 severity to levels consistent with the levels seen in healthy patients. Convolution of corneal HOAs with the Early Treatment Diabetic Retinopathy Study chart provides a useful simulation of the impact of pinhole optics in aberrated eyes.
The purpose of this study is to evaluate the potential impact of small aperture optics on corneal aberrations in post-RK patients. Preoperative data was evaluated from 32 eyes of 23 post-RK patients. Scheimpflug tomography was used to obtain measurements of corneal HOAs at 6-mm, 4-mm, and 2-mm corneal plane aperture diameters. The data was extrapolated using a non-linear fit to estimate HOAs that would be obtained with the 1.6 mm effective pinhole IOL aperture at the corneal plane for individual patients. The average RMS HOAs estimated for the 1.6 mm aperture was 0.063 ± 0.015 μm compared to 0.185 ± 0.029 μm for the natural pupil size. A postoperative RK case with an IC-8® Apthera™ unilateral implantation demonstrated a 70% reduction in HOAs by objective measurement and prediction, plus a 2-line improvement in CDVA. Prediction modeling revealed that HOAs may be reduced in post-RK patients following pinhole IOL implantation, compared to the natural photopic pupil size. Furthermore, the approach can be used to guide which post-RK patients would benefit from a small aperture IOL during cataract surgery.
Intrastromal corneal ring segments (ICRS) improve corneal topographic symmetry and reduce corneal aberrations through regularization of the corneal surface, thereby functioning as a viable surgical intervention for patients with keratoconus. This study aims to evaluate changes in lower- (LOAs) and higher-order aberrations (HOAs) amongst varying pupil sizes pre- and post- ICRS implantation in keratoconus patients. We specifically investigate the impact of pupil size on total corneal HOAs up to the 6th order. Twenty-one eyes that underwent ICRS implantation were included in this prospective interventional study. LOAs and HOAs measurements at the 6 mm, 4 mm, and 2 mm pupil diameters were collected preoperatively and at 6 months postoperatively using the Zernicke analysis function on a Scheimpflug device. ICRS implantation demonstrated a statistically significant effect in vertical coma with a −0.23 reduction (p = 0.015) for a 4 mm pupil size and a −1.384 reduction (p < 0.001) for 6 mm, with no significant effect at 2 mm. Horizontal coma, astigmatism 0°, astigmatism 45°, trefoil 5th order 30°, and RMS HOA demonstrated significant reductions at 4 mm or 6 mm pupil sizes but not at 2 mm. Our analysis demonstrates a favorable effect of ICRS implantation on larger pupil sizes, suggesting the importance of pupil size as it correlates with HOAs reduction.
The objective of this study was to compare subjective manifest refraction with wavefront-based automated refraction using iTrace (ray tracing) and LadarWave (Hartmann–Shack) in eyes implanted with two enhanced monofocal intraocular lenses (IOLs) and a standard aspheric monofocal IOL, emphasizing agreement and refractive variability across optical designs. This retrospective cohort included 84 eyes from 42 patients implanted with Tecnis Eyhance (DIB00), RayOne EMV (RAO200E), or Tecnis ZCB00 IOLs. Postoperative evaluation (1–3 months) included uncorrected and corrected distance visual acuity and subjective manifest refraction, followed by automated refraction with iTrace and LadarWave. Outcomes were sphere, cylinder, and spherical equivalent (SE). Agreement was assessed using mean signed difference, mean absolute error, root mean square error, Bland–Altman limits of agreement, proportions within clinically relevant thresholds, and vector astigmatism (J0, J45). Linear mixed-effect modeling evaluated SE differences across methods and IOL types while accounting for within-subject correlation. Subjective SE differed among IOLs (p = 0.027), with RAO200E more myopic than ZCB00 (−0.20 ± 0.32 D vs. −0.08 ± 0.44 D, p = 0.035). Automated refraction showed greater variability and poorer agreement in enhanced monofocal IOLs, particularly for cylinder and SE, with wider limits of agreement and fewer eyes within ±0.50 D compared with ZCB00. In mixed-effect contrasts (three-method repeated-measures model), iTrace and LadarWave showed a consistent myopic bias versus manifest refraction in DIB00 and RAO200E, whereas in ZCB00 the iTrace–manifest difference was not significant and LadarWave retained a significant myopic bias. Enhanced monofocal IOLs exhibit reduced agreement between wavefront-based automated and subjective manifest refraction compared with a standard aspheric monofocal IOL. Manifest refraction remains essential for postoperative assessment, and automated measurements should be interpreted as complementary, particularly in IOL designs that modify aberrations.
9 September 2026 in Journal of Cataract & Refractive Surgery
Purpose: To evaluate the influence of preoperative astigmatism magnitude and axis on the selection between nontoric and low-powered trifocal toric intraocular lenses (IOLs) and their comparative refractive outcomes. Setting: Memira by Bergman Clinics, Norway; HO Londrina—Hospital de Olhos, Brazil. Design: Multicenter, retrospective, interventional cohort study. Methods: Consecutive eyes designated for nontoric (T00) or low-powered toric (T20) trifocal IOLs based exclusively on Barrett Toric Calculator recommendations were analyzed. Generalized estimating equations were used to adjust for intereye correlation. Outcomes included preoperative corneal astigmatism (magnitude and axis), estimated residual astigmatism, and postoperative manifest astigmatism, evaluated with double-angle and linear distribution plots. Results: The cohort comprised 1628 eyes (T00: 786; T20: 842). The calculator's recommendation between T00 and T20 varied continuously based on both preoperative magnitude and axis. Despite the T20 group having significantly higher preoperative corneal astigmatism ( P < .001), postoperative manifest astigmatism was statistically equivalent between groups (T00: 0.26 ± 0.26 diopters [D] vs T20: 0.24 ± 0.26 D; P = .634). No significant differences were observed in visual acuity, manifest refraction spherical equivalent, safety, or efficacy indices ( P > .05). However, the T00 group demonstrated higher estimated than achieved postoperative astigmatism (0.33 ± 0.16 D vs 0.26 ± 0.26 D), whereas the T20 group showed lower estimated than achieved astigmatism (0.10 ± 0.08 D vs 0.24 ± 0.26 D). Conclusions: The decision between a nontoric vs a low-powered toric IOL relies on an individualized interdependence between magnitude and axis rather than a fixed magnitude-based cutoff. This individualized, calculator-driven approach was associated with comparable postoperative astigmatism between groups, regardless of their baseline differences.