Mehran Yarahmadi

Dr. Mehran Yarahmadi


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2017 in Medical Physics
Verified
Journal Article
Closed access
PDF file
MYMehran Yarahmadi
Mehran Yarahmadi
SWSonja Wegener
Sonja Wegener
OSOtto A. Sauer
Otto A. Sauer

1 December 2013 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Open access
MYMehran Yarahmadi
Mehran Yarahmadi
MAMahmoud Allahverdi
Mahmoud Allahverdi
HNHassan A. Nedaie
Hassan A. Nedaie
KAKhadijeh Asnaashari
Khadijeh Asnaashari
SVSayed A. Vaezzadeh
Sayed A. Vaezzadeh
OSOtto A. Sauer
Otto A. Sauer
Background: In stereotactic radiosurgery, sharp beam edges have clear advantages to spare normal tissues. In general, the dose gradient is a limiting factor in minimizing dose to nearby critical structures for clinical cases. Therefore the penumbral width should be diminished. Methods: A Varian Clinac 2100 linear accelerator equipped with in-house designed radiosurgical collimator was modeled using the EGSnrc/BEAMnrc Monte Carlo code and compared with the measurements. The 0.015 cm(3) PinPoint chamber was used to measure the 6 MV photon beam characteristics and to validate Monte Carlo calculations. Additional to the standard (STD) linac, a flattening filter free (FFF) linac was simulated. Percent depth doses, beam profiles and output factors were calculated for small field sizes with diameter of 5, 10, 20 and 30 mm with DOSXYZnrc. The mean energy and photon fluence at the water surface were calculated with BEAMDP for both FFF linac and STD linacs. Results: The penumbra width (80%-20%) was decreased by 0.5, 0.3, 0.2 and 0.2 mm for field sizes of 5, 10, 20 and 30 mm respectively when removing the FE The fluence of photons at the surface increased up to 3.6 times and the mean energy decreased by a factor of 0.69 when removing the FE The penumbra width (80%-20%) decreased by 17% when a 2 MeV monoenergetic electron pencil beam incident on the target is used instead of 6.2 MeV. Conclusions: It was found that the penumbra of small field sizes is decreased by removing the FF. Likewise using low megavoltage photons reduced the beam penumbra maintaining adequate penetration and skin sparing.

25 June 2018 in Australasian Physics & Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
AHAbbas Haghparast
Abbas Haghparast
FAFatemeh Amiri
Fatemeh Amiri
MYMehran Yarahmadi
Mehran Yarahmadi
MRMohammad Rezaei
Mohammad Rezaei

19 December 2019 in Reports of Practical Oncology and Radiotherapy
Verified
Journal Article
Closed access
NJNegin Javaheri
Negin Javaheri
MYMehran Yarahmadi
Mehran Yarahmadi
ARAbdollah Refaei
Abdollah Refaei
AAAli Aghamohammadi
Ali Aghamohammadi
Background: Three dimensional (3D) dosimetry methods are useful for advanced radiotherapy techniques such as stereotactic radiosurgery (SRS) and high dose rate (HDR) brachytherapy. Polymer gel is one of the more reliable 3D dosimetry techniques. More studies are needed to improve the efficiency of polymer gels for their application in dosimetry. Aim: In the current study, the best protocol for reading of N-isopropyl acrylamide (NIPAM) polymer gel by X-ray computed tomography (CT) was implemented for application in radiotherapy. Material and methods The NIPAM gel was made and irradiated by 6 MV. Its reading was done by the X-ray CT after 24 h and the information examined by using the MATLAB software. In the present work, the different effects of slice thicknesses and voltages were investigated for its lower toxicity of NIPAM polymer gel. The results of a recipe of different filtering on the response curve of polymer gel was investigated. Results: The measured dose sensitivity wasΔNCTH = 0.29 ± 0.01 HGy-1 for the NIPAM dosimeter. The best sensitivity was achieved for 120 kVp and the slice thickness of 10 mm. The greater slice thickness gained more desirable sensitivity. This process was repeated by using different filtering with different thicknesses to obtain the best sensitivity. Conclusions: The sensitivity of X-ray CT reading technique of NIPAM Polymer gel depended on the slice thickness and kVp. The wiener2 filtering was useful to improving sensitivity.

1 January 2023 in Journal of Medical Physics
Verified
Journal Article
Open access
SASoma Saeed Mohammed Amin
Soma Saeed Mohammed Amin
KFKharman Akarm Faraj
Kharman Akarm Faraj
JAJalil Salih Ali
Jalil Salih Ali
HRHawzhin Abdalla Hama Rahim
Hawzhin Abdalla Hama Rahim
MYMehran Yarahmadi
Mehran Yarahmadi
Purpose: The aim of this study was to investigate demographic and dosimetric parameters which may link with esophagitis in patients with breast cancer receiving three-dimensional conformal radiotherapy to the supraclavicular fossa. Materials and Methods: We examined 27 breast cancer patients with supraclavicular metastases. All patients were treated with radiotherapy (RT) with a prescribed dose of 40.5 Gy in 15 fractions for 3 weeks. Esophagitis was recorded weekly and esophagus toxicity was evaluated and graded according to the tadiation therapy oncology group. The following factors were examined regarding their correlation with grade 1 or worse esophagitis by univariate and multivariate analyses: age, chemotherapy, smoking history, maximum dose (Dmax), mean dose (Dmean), esophagus volume receiving 10 Gy (V10), esophagus volume receiving 20 Gy (V20), and length of esophagus in the treatment field. Results: Of 27, 11 (40.7%) patients developed no esophageal irritation throughout therapy. Approximately half of the patients 13/27 (48.1%) had maximum grade 1 esophagitis. 2/27 (7.4%) patients had grade 2 esophagitis. The incidence of grade 3 esophagitis was (3.7%). Dmean, Dmax, V10, and V20 were 10.48 ± 5.10 Gy, 38.18 ± 5.12Gy, 29.83 ± 15.16, and 19.32 ± 10.01, respectively. Our results showed that Dmean, V10, and V20 were the significant factors for the development of esophagitis, whereas esophagitis was not significantly associated with the chemotherapy regimen, age, and smoking status. Conclusions: We found that Dmean, V10, and V20 correlated significantly with acute esophagitis. However, the chemotherapy regimen, age, and smoking status did not affect esophagitis development.

1 January 2016 in International Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
WPW. Parwaie
W. Parwaie
MYMehran Yarahmadi
Mehran Yarahmadi
HNH.A. Nedaie
H.A. Nedaie
MZM.H. Zahmatkesh
M.H. Zahmatkesh
ABA.H. Barati
A.H. Barati
MAM. Afkhami
M. Afkhami
IJRR- International Journal of Radiation Research