Otto A. Sauer

Otto A. Sauer

Auto-generated profile, based on publicly available information

Otto A. Sauer

Department of Radiation Oncology, University of Würzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2017 in Medical Physics
Verified
Journal Article
Closed access
PDF file
MYMehran Yarahmadi
Mehran Yarahmadi
SWSonja Wegener
Sonja Wegener
OSOtto A. Sauer
Otto A. Sauer

8 November 2016 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
ARAnne Richter
Anne Richter
Bülent PolatBülent Polat
Bülent Polat
ILIngulf Lawrenz
Ingulf Lawrenz
SWStefan Dr. Weick
Stefan Dr. Weick
OSOtto Sauer
Otto Sauer
FMFrederick Mantel
Frederick Mantel
Evaluation of set up error detection by a transperineal ultrasound in comparison with a cone beam CT (CBCT) based system in external beam radiation therapy (EBRT) of prostate cancer. Setup verification was performed with transperineal ultrasound (TPUS) and CBCT for 10 patients treated with EBRT for prostate cancer. In total, 150 ultrasound and CBCT scans were acquired in rapid succession and analyzed for setup errors. The deviation between setup errors of the two modalities was evaluated separately for each dimension. A moderate correlation in lateral, vertical and longitudinal direction was observed comparing the setup errors. Mean differences between TPUS and CBCT were (−2.7 ± 2.3) mm, (3.0 ± 2.4) mm and (3.2 ± 2.7) mm in lateral, vertical and longitudinal direction, respectively. The mean Euclidean difference between TPUS and CBCT was (6.0 ± 3.1) mm. Differences up to 19.2 mm were observed between the two imaging modalities. Discrepancies between TPUS and CBCT of at least 5 mm occurred in 58 % of monitored treatment sessions. Setup differences between TPUS and CBCT are 6 mm on average. Although the correlation of the setup errors determined by the two different image modalities is rather week, the combination of setup verification by CBCT and intrafraction motion monitoring by TPUS imaging can use the benefits of both imaging modalities.

7 January 2017 in Medical Physics
Verified
Journal Article
Open access
PDF file
SWSonja Wegener
Sonja Wegener
OSOtto A. Sauer
Otto A. Sauer
Purpose Separating the scatter from the primary component of a MV beam to study detector response separately in each case for a better understanding of the role of different effects influencing the response in nonstandard fields. Methods Detector response in three different experimental setups was investigated for a variety of different types (diamond, shielded and unshielded diodes, ionization chamber and film): (a). Detectors positioned in water under a thin steel pole blocking the central part of the beam, yielding only the response to the scatter part of the beam. (b). Detectors positioned in air under a PMMA cap to approximate the contribution of the primary beam without scatter. (c). Detectors positioned in water in the standard open field configuration to obtain a superposition of both. Results Detector differences became more clearly observable when the primary beam was blocked and detector behavior heavily depended on the construction type. It was possible to calculate the response in the open fields from the values measured in the blocked configuration with 1% accuracy for all studied field sizes between 0.8 and 10 cm and for all detectors. Conclusions The limitations of clinically used detectors in nonstandard situations were illustrated in the extreme situation of just scattered radiation reaching the detector. By experimentally separating scatter from the primary beam, the roles of different effects on the detector response were observed.

1 January 2014 in Physica Medica
Verified
Journal Article
Closed access
MYMehran Yarahmadi
Mehran Yarahmadi
HNHassan A. Nedaie
Hassan A. Nedaie
OSOtto A. Sauer
Otto A. Sauer

1 January 2017 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
BHBarbara Herzog
Barbara Herzog
SWSonja Wegener
Sonja Wegener
OSOtto A. Sauer
Otto A. Sauer