Anne Migan Migan Dubois

Prof. Dr. Anne Migan Migan Dubois

GeePs-Laboratoire de Génie Électrique et Électronique de Paris, CNRS, Institut Polytechnique de Paris, Sorbonne Université, 91120 Palaiseau, France

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2019 in Progress in Photovoltaics: Research and Applications
Verified
Journal Article
Closed access
PDF file
ZDZakaria Djebbour
Zakaria Djebbour
WEWalid El‐Huni
Walid El‐Huni
ADAnne Migan Migan Dubois
Anne Migan Migan Dubois
JKJean‐Paul Kleider
Jean‐Paul Kleider

15 October 2021 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
ADAnne Migan Migan Dubois
Anne Migan Migan Dubois
JBJordi Badosa
Jordi Badosa
VBVincent Bourdin
Vincent Bourdin
MAMoira I. Torres Aguilar
Moira I. Torres Aguilar
YBYvan Bonnassieux
Yvan Bonnassieux
The simulation of photovoltaic installations is a major issue for their sizing, their smart grid operation, and their fault detection and diagnosis. In this article, we study in detail every step of the simulation chain, either from the global horizontal irradiance and the ambient temperature (i.e., 4 steps of simulation) or considering the global in-plane irradiance and the module operating temperature (i.e., 1 step of simulation). The average quality estimation of the models is made through the calculations of average annual error between estimations and measurements, from 2016 to 2020. We have shown that the most uncertain step is the conversion of the global irradiance in its diffuse and direct components (17.2%, 2 models tested). If the model goes up to the in-plane irradiance, the average annual error decreases to 5.3% (6 models tested). The photovoltaic module temperature calculation induces an error of less than 2°C (4 models tested with 2 configurations). Meanwhile, the photoelectrical conversion shows a 3.5% error, similar to the measurement uncertainties, considering as input, the modules temperature, and the in-plane irradiance. If the simulation goes from the global irradiance and the ambient temperature measured locally, the estimation leads to a 6.7% average annual error. If the local measurements are not available, we can use the closest meteorological station’s records (13 for our study), and the error becomes 12.1%. Finally, we can also use the satellite images that lead to a 15.2% error, for average per year. The impact of available input shows that modeling the DC photovoltaic production, using global horizontal irradiance and ambient temperature, gives rise to an error of 6.6% for local measurements, 12.1% for weather station measurements, and 15.2% for satellite images estimations. This article thus draws up a review of the existing models, allowing to calculate the DC production of a photovoltaic module, depending on the atmospheric conditions, and highlights the most precise or most critical steps, considering in situ and weather station ground-based measurements, and also estimation from satellite images.

11 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
FCFausto CALDERON-OBALDIA
Fausto CALDERON-OBALDIA
JBJordi Badosa
Jordi Badosa
ADAnne Migan Migan Dubois
Anne Migan Migan Dubois
VBVincent Bourdin
Vincent Bourdin
The research work hereby presented, emerges from the urge to answer the well-known question of how the uncertainty of intermittent renewable sources affects the performance of a microgrid and how could we deal with it. More specifically, we want to evaluate what could be the impact in performance of a microgrid that is intended to serve a smart-building (powered by photovoltaic panels and with battery energy storage), when the uncertainty of the photovoltaic-production forecasts is considered in the energy management process through the use of quantile forecasts. For this, several objectives (or services) are targeted based in a two-step (double-objective) energy management framework, which combines optimization-based and rule-based algorithms. The performance is evaluated based on some particular services, namely: energy cost, carbon footprint, grid peak power, and grid commitment; with the latter being a novel service proposed in the domain of microgrids. Simulations are performed whlie using data of a study-case microgrid (Drahi-Xnovation center, Ecole Polytechnique, France). The use of quantile forecasts (obtained with an analog-ensemble method) is tested as a mean to deal with (i.e., decrease) the uncertainty of the solar PV production. The proposed energy management framework is compared with basic reference strategies and the results show the superior performance of the former in almost all of the proposed services and forecasting scenarios. The fact of how optimizing for some services during the scheduling (i.e., grid commitment) can be highly detrimental for the performance of the non-targeted services, is an interesting finding of this work. The differences regarding the optimal forecasting eccentricity (i.e., the forecasting quantile) required when optimizing for the different services and seasons of the year is also considered an important conclusion of the study. This fact highlights the usefulness of the quantile forecasting approach in an energy management system, as a tool to deal with the intrinsic uncertainty of PV power production.

26 August 2008 in Journal of Crystal Growth
Verified
Journal Article
Closed access
SGS. Gautier
S. Gautier
TAT. Aggerstam
T. Aggerstam
APA. Pinos
A. Pinos
SMS. Marcinkevičius
S. Marcinkevičius
KLK. Liu
K. Liu
AOAbdallah Ougazzaden
Abdallah Ougazzaden

13 November 2024 in IEEE Access
Verified
Journal Article
Open access
MZMohsen Zargarani
Mohsen Zargarani
CDClaude DELPHA
Claude DELPHA
DDDemba Diallo
Demba Diallo
ADAnne Migan Migan Dubois
Anne Migan Migan Dubois
CMChabakata MAHAMAT
Chabakata MAHAMAT
LLLaurent Linguet
Laurent Linguet
The role of clustering in unsupervised fault diagnosis is significant, but different clustering techniques can yield varied results and cause inevitable uncertainty. Ensemble clustering methods have been introduced to tackle this challenge. This study presents a novel integrated technique in the field of fault diagnosis using spectral ensemble clustering. A new dimensionality reduction technique is proposed to intelligently identify faults, even in ambiguous scenarios, by exploiting the informative segment of the underlying bipartite graph. This is achieved by identifying and extracting the most informative sections of the bipartite graph based on the eigenvector centrality measure of nodes within the graph. The proposed method is applied to experimental current-voltage (I-V) curve data collected from a real photovoltaic (PV) platform. The obtained results remarkably improved the accuracy of aging fault detection to more than 83.50%, outperforming the existing state-of-the-art approaches. We also decided to separately analyze the ensemble clustering part of our FDD method, which indicated surpassing performance compared to similar methods by evaluating commonly used datasets like handwritten datasets. This proves that the proposed approach inherently holds promise for application in various real-world scenarios that are indicated by ambiguity and complexity.

16 July 2025 in Energy Conversion and Management
Verified
Journal Article
Closed access
KJKhadim Ullah Jan
Khadim Ullah Jan
GFGhjuvan Antone Faggianelli
Ghjuvan Antone Faggianelli
JDJean-Laurent Duchaud
Jean-Laurent Duchaud
ADAnne Migan Migan Dubois
Anne Migan Migan Dubois
Demba DialloDemba Diallo
Demba Diallo