Hyo-Jin Byon

Dr. Hyo-Jin Byon


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of Korean Medical Science
Verified
Journal Article
Open access
JLJi-Hyun Lee
Ji-Hyun Lee
HBHyo-Jin Byon
Hyo-Jin Byon
SCSeungeun Choi
Seungeun Choi
YJYoung-Eun Jang
Young-Eun Jang
HKHee-Soo KIM
Hee-Soo KIM
HKHee-Soo KIM
Hee-Soo KIM
Lee JH, et al. J Korean Med Sci. 2018 Jul;33(37):e227. https://doi.org/10.3346/jkms.2018.33.e227

27 July 2013 in Anaesthesia
Verified
Journal Article
Open access
PDF file
HKH. Kim
H. Kim
CJC‐H. Jeong
C‐H. Jeong
HBHyo-Jin Byon
Hyo-Jin Byon
HSH. K. Shin
H. K. Shin
TYT. J. Yun
T. J. Yun
JKJ‐T. Kim
J‐T. Kim
Summary: The aim of this study was to predict the optimal depth for insertion of a left‐sided central venous catheter in children. Using 3D chest computed tomography angiography, we measured the distance from a point where the internal jugular vein is at the superior border of the clavicle, and from a point where the subclavian vein is inferior to the anterior border of the clavicle, to the junction of the superior vena cava and the right atrium in 257 children. Linear regression analysis revealed that the distances correlated with age, weight and height. Simple formulae for the depth of a central venous catheter via the left internal jugular vein (0.07 × height (cm)) and the left subclavian vein (0.08 × height (cm)) were developed to predict placement of the central venous catheter tip at the junction of the superior vena cava with the right atrium. Using these fomulae, the proportion of catheter tips predicted to be correctly located was 98.5% (95% CI 96.8–100%) and 94.0% (95% CI 90.8–97.3%), respectively.

27 May 2015 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
HKHee-Soo KIM
Hee-Soo KIM
HBHyo-Jin Byon
Hyo-Jin Byon
JKJong-Eun Kim
Jong-Eun Kim
YPYong-Hee Park
Yong-Hee Park
JLJi-Hyun Lee
Ji-Hyun Lee
JKJin-Tae Kim
Jin-Tae Kim
Dexmedetomidine can be used for the prevention of emergence agitation (EA) in children. However, an inadequate dose of dexmedetomidine can induce prolonged sedation and cardiovascular complications. The aim of this study was to evaluate the effective dose of dexmedetomidine for the prevention of EA after desflurane anesthesia for patients undergoing a tonsillectomy or adenoidectomy. We enrolled 21 unpremedicated children, between 2 and 12 years, undergoing either a tonsillectomy or an adenoidectomy. General anesthesia was induced using sevoflurane and oxygen, and dexmedetomidine was administered before surgery. Anesthesia was maintained using desflurane resulting in a BIS range of 40–60. In the postanesthetic care unit (PACU), EA (agitation measured at level 4 or more at least once) was assessed on arrival in the PACU,15 min later, and 30 min later. The dose of dexmedetomidine for consecutive patients was determined by the response of the previous patient, using an increment or decrement of 0.1 μg/kg. The 50 % effective dose of dexmedetomidine for prevention of EA was 0.25 μg/kg (95 % confidence limits, 0.17–0.33 μg/kg), and the 95 % effective dose was 0.38 μg/kg (95 % confidence limits, 0.29–0.39 μg/kg). For prevention of EA after desflurane anesthesia for 50 % and 95 % of children undergoing tonsillectomies or adenoidectomies, 0.25 μg/kg or 0.38 μg/kg of dexmedetomidine is suggested. Further study is needed to validate the suggested dose of dexmedetomidine to prevent the EA that was identified in the present study. Clinical Research Information Service KCT0000126 .

6 October 2021 in Pediatric Anesthesia
Verified
Journal Article
Closed access
PDF file
HKHyun Il Kim
Hyun Il Kim
JMJi Young Min
Ji Young Min
JLJeong‐Rim Lee
Jeong‐Rim Lee
CWChoi Kwan Woong
Choi Kwan Woong
MCMatthew R. Cho
Matthew R. Cho
HBHyo-Jin Byon
Hyo-Jin Byon

7 March 2011 in The Thoracic and Cardiovascular Surgeon
Verified
Journal Article
Closed access
PDF file
HBHyo-Jin Byon
Hyo-Jin Byon
HKHyun-Chang Kim
Hyun-Chang Kim
JKJin-Tae Kim
Jin-Tae Kim
HKH.-S. Kim
H.-S. Kim
SLS.-C. Lee
S.-C. Lee
CKC. Kim
C. Kim
To evaluate the potential risk for intra-aortic balloon (IAB)-induced obstruction to the celiac axis (CA) or the renal artery (RA) when IAB size is chosen according to patient height and the tip is placed 2 cm distal to the origin of the left subclavian artery (LSCA), the computed tomography images of 150 Asian adults were reviewed to identify the distance from the LSCA to the CA (LSCA‐CA) and to the RA (LSCA‐RA). The diameter of the aorta at the level of the T9 vertebra, CA, and RA was also measured. The length and caliber of the IAB was selected according to two manufacturer's recommendations (Datascope Corp and Tokai Medical Products). The Datascope IAB potentially blocked the CA in 84 % and the RA in 66 %, while the Tokai IAB obstructed the CA in 61 % and the RA in 10 % of cases. The caliber of the IAB overlying the orifice of the RA was longer than the diameter of the aorta in 5 cases (3.3 %) using the Datascope IAB, and in 1 case (0.7 %) using the Tokai IAB. When placing an IAB selected based on patient height, the IAB could obstruct the orifice of the CA and RA in the majority of Asian patients, especially a Datascope IAB.

18 January 2021 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
NKNamo Kim
Namo Kim
HKHyun Il Kim
Hyun Il Kim
DKDo-Hyeong Kim
Do-Hyeong Kim
DPDahee Park
Dahee Park
SSSei Han Song
Sei Han Song
HBHyo-Jin Byon
Hyo-Jin Byon
Background: Radial artery cannulation can cause complications such as haematoma formation or thrombosis due to its small diameter. Recently, a novel ultrasound device equipped with an electromagnetic guidance system was introduced, showing the path and alignment of the needle during the procedure. The aim of this study was to investigate the effects of this novel system on both success and complication rates during radial artery cannulation under ultrasound guidance. Methods: In this randomized controlled trial, 76 adults scheduled for neurosurgery requiring radial artery cannulation were recruited. In group E (n = 38), radial artery cannulation was performed using the electromagnetic guidance ultrasound system, whereas in group C (n = 38), the procedure was performed using conventional ultrasound guidance. The success rates of cannulation on the first attempt, cannulation times, number of attempts, and incidence of complications were compared between the two groups. Results: There was a significant difference in the success rates on the first attempt between the two groups (group C = 78.9% vs. group E = 94.7%, P = 0.042). Incidences of posterior wall puncture and haematoma formation (group C = 8 vs. group E = 1; P = 0.028) were significantly lower in group E than in group C. The median cannulation time for successful attempts was comparable between groups. Conclusions: Use of the novel electromagnetic guidance system resulted in a better success rate on the first attempt and a lower incidence of complications during radial artery cannulation. Trial registration: This study was registered at http://cris.nih.go.kr (registration number: KCT0002476).