Mansour Rahsepar

Dr. Mansour Rahsepar


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2020 in Polymers
Verified
Journal Article
Open access
PDF file
SHSeyyed Alireza Hashemi
Seyyed Alireza Hashemi
SMSeyyed Mojtaba Mousavi
Seyyed Mojtaba Mousavi
RFReza Faghihi
Reza Faghihi
Mohammad ArjmandMohammad Arjmand
Mohammad Arjmand
MRMansour Rahsepar
Mansour Rahsepar
Chin Wei LaiChin Wei Lai
Chin Wei Lai
X-ray radiation is a harmful carcinogenic electromagnetic source that can adversely affect the health of living species and deteriorate the DNA of cells, thus it’s vital to protect vulnerable sources from them. To address this flaw, the conductive polymeric structure of polyaniline (PANi) was reinforced with diverse filler loadings (i.e., 25 wt % and 50 wt %) of hybrid graphene oxide-iron tungsten nitride (ITN) flakes toward attenuation of X-ray beams and inhabitation of microorganisms’ growth. Primary characterizations confirmed the successful decoration of graphene oxide (GO) with interconnected and highly dense structure of iron tungsten nitride with a density of about 24.21 g·cm−3 and reinforcement of PANi with GO-ITN. Additionally, the outcome of evaluations showed the superior performance of developed shields, where a shield with 1.2 mm thickness containing 50 wt % GO-ITN showed 131.73% increase in the electrical conductivity (compared with neat PANi) along with 78.07%, 57.12%, and 44.99% decrease in the amplitude of the total irradiated X-ray waves at 30, 40, and 60 kVp tube voltages, respectively, compared with control X-ray dosage. More importantly, the developed shields not only showed non-toxic nature and improved the viability of cells, but also completely removed the selected microorganisms at a concentration of 1000 µg·mL−1.

1 October 2012 in Applied Catalysis B: Environment and Energy
Verified
Journal Article
Closed access
MRMansour Rahsepar
Mansour Rahsepar
MPMahmoud Pakshir
Mahmoud Pakshir
PNPavel Nikolaev
Pavel Nikolaev
ASAfsaneh Safavi
Afsaneh Safavi
KPKowsalya Palanisamy
Kowsalya Palanisamy
HKHasuck Kim
Hasuck Kim

9 May 2024 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
MKMaryam Karandish
Maryam Karandish
NHNegar Hajipour
Negar Hajipour
HYHanieh Yazdani
Hanieh Yazdani
MMMona Mahdavi
Mona Mahdavi
MRMansour Rahsepar
Mansour Rahsepar
Releasing of metal ions might implicate in allergic reaction as a negative subsequent of the corrosion of Stainless Steel (SS304) orthodontic wires. The aim of this study was to evaluate the corrosion resistance of zinc-coated (Zn-coated) SS orthodontic wires. Zinc coating was applied on SS wires by PVD method. Electrochemical impedance spectroscopy (EIS), Potentiodynamic polarization tests and Tafel analysis methods were used to predict the corrosion behavior of Zn-coated and uncoated SS wires in both neutral and acidic environments. The values of Ecorr ,icorr and Rct ,which were the electrochemical corrosion characteristics, reported better corrosion behavior of Zn-coated SS wires against uncoated ones in both artificial saliva and fluoride-containing environments. Experimental results of the Tafel plot analyses were consistent with that of electrochemical impedance spectroscopy analyses for both biological solutions. Applying Zn coating on bare SS orthodontic wire by PVD method might increase the corrosion resistance of the underlying stainless-steel substrate.

14 September 2015 in Journal of Failure Analysis and Prevention
Verified
Journal Article
Closed access
PDF file
MRMansour Rahsepar
Mansour Rahsepar
MAMohammad Asgharzadeh
Mohammad Asgharzadeh
MHMohammad Jafar Hadianfard
Mohammad Jafar Hadianfard
SJSeyed Ahmad Jenabali Jahromi
Seyed Ahmad Jenabali Jahromi