LI FANG QING

LI FANG QING


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2026 in Energies
Verified
Journal Article
Open access
PDF file
YLYuxing LEI
Yuxing LEI
BLBo Li
Bo Li
YYYingjie Yin
Yingjie Yin
LQLI FANG QING
LI FANG QING
JSJiao Sun
Jiao Sun
ZWzhensheng Wu
zhensheng Wu
A fault-section location method based on waveform-difference analysis of transient zero-sequence currents is proposed for distribution networks with small-current grounding systems. The method addresses weak single-phase-to-ground fault-current amplitudes, indistinct fault features, and limited adaptability of steady-state-quantity-based location criteria under arc-suppression-coil compensation. Steady-state and transient characteristics of single-phase-to-ground faults were analyzed in neutral-point ungrounded systems and arc-suppression-coil-grounded systems. Transient zero-sequence currents exhibited more pronounced amplitude, polarity, and waveform differences than steady-state zero-sequence currents, with lower sensitivity to compensation effects. These characteristics provide effective features for fault-section discrimination. The discrete Fréchet distance was used to quantify the overall waveform difference between transient zero-sequence currents at both ends of each line section. The coefficient of variation was introduced to characterize the dispersion of waveform differences among different sections. A fault-section location criterion was then constructed. The location performance was verified through PSCAD/EMTDC–MATLAB co-simulation under different neutral-point grounding modes, transition resistances, and fault inception angles. The results show that the proposed method accurately identifies fault sections and maintains good adaptability under both distinct and weak fault-feature conditions. Compared with the correlation-coefficient method, grey relational analysis, and empirical mode decomposition, the proposed method more comprehensively characterizes waveform differences in transient zero-sequence currents at both ends of a line section. It shows good section-discrimination capability under the representative fault conditions considered in this study.

17 August 2026 in Electronics
Verified
Journal Article
Open access
PDF file
KLKai Luo
Kai Luo
LZLong Zhang
Long Zhang
朱朱朱国福 国福 朱
朱国福 国福 朱
SKShaochao Kang
Shaochao Kang
SZShaolei Zhai
Shaolei Zhai
YLYuqi Li
Yuqi Li
This paper presents a compact, high-performance microstrip tri-band bandpass filter (BPF) based on a cross-coupling structure. By virtue of the structural symmetry, the evenodd mode analytical method based on the ABCD matrix theory is applied to characterize the transmission mechanisms and resonance conditions. Benefiting from the signal transmission between the dual paths, five transmission zeros are generated at 3.14, 3.56, 4.11, 5.55, and 5.61 GHz. Meanwhile, the center frequencies and fractional bandwidths of the three operating bands can be independently adjusted by tuning specific dimensions. The measured center frequencies are located at 2.50, 4.73 and 6.30 GHz, with corresponding 3 dB FBWs of 34.8%, 16.1% and 16.5%, respectively. The measured results show a good agreement with the Ansys HFSS full-wave EM simulations.