Yuxing LEI

Dr. Yuxing LEI


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2026 in Nanomaterials
Verified
Journal Article
Open access
PDF file
BLBo Li
Bo Li
NZNanhui Zhang
Nanhui Zhang
YLYuxing LEI
Yuxing LEI
PSPeng Sun
Peng Sun
HYHaitao Yang
Haitao Yang
Electric-field-sensitive dielectrics play a crucial role in electric field induction sensing and related capacitive conversion, with interfacial polarization and charge accumulation largely determining the signal output. This paper introduces graphene/transition metal dichalcogenide (TMD) (MoSe2, MoS2, and WS2) heterojunctions as functional fillers to enhance the dielectric response and electric-field-induced voltage output of flexible polydimethylsiloxane (PDMS) composites. Density functional theory (DFT) calculations were used to evaluate the stability of the heterojunctions and interfacial electronic modulation, including binding behavior, charge redistribution, and Fermi level-referenced band structure/total density of states (TDOS) characteristics. The calculations show that the graphene/TMD interface is primarily controlled by van der Waals forces, exhibiting negative binding energy and significant interfacial charge rearrangement. Based on these theoretical results, graphene/TMD heterojunction powders were synthesized and incorporated into polydimethylsiloxane (PDMS). Structural characterization confirmed the presence of face-to-face interfacial contacts and consistent elemental co-localization within the heterojunction filler. Dielectric spectroscopy analysis revealed an overall improvement in the dielectric constant of the composite materials while maintaining a stable loss trend within the studied frequency range. More importantly, calibrated electric field induction tests (based on pure PDMS) showed a significant enhancement in the voltage response of all heterojunction composite materials, with the WS2-G/PDMS system exhibiting the best performance, exhibiting an electric-field-induced voltage amplitude 7.607% higher than that of pure PDMS. This work establishes a microscopic-to-macroscopic correlation between interfacial electronic modulation and electric-field-sensitive dielectric properties, providing a feasible interface engineering strategy for high-performance flexible dielectric sensing materials.

11 February 2026 in Crystals
Verified
Journal Article
Open access
PDF file
BLBo Li
Bo Li
JSJiao Sun
Jiao Sun
YLYuxing LEI
Yuxing LEI
LSLuyao Shi
Luyao Shi
HYHaitao Yang
Haitao Yang
Flexible dielectric composite materials capable of converting power frequency electric fields into measurable electrical signals are of great significance in the field of non-contact electric field sensing in power systems. In this paper, graphene/nitride heterojunction powders were prepared using three representative nitrides (AlN, BN, and Si3N4) and embedded in polydimethylsiloxane (PDMS) to prepare flexible composite films with a fixed filler content of 5.0 wt%. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) confirmed the successful formation of the heterojunctions. The results showed that the nitride-related elements (Al, Si and N) were spatially correlated with the graphene-rich regions, thus providing abundant interfacial contact sites. Dielectric spectroscopy (50 Hz–50 kHz) showed that all samples exhibited typical dispersive behavior, with the real part of the dielectric constant decreasing monotonically with increasing frequency, and the loss tangent also decreasing smoothly. Under a 50 Hz parallel-plate electric field, the normalized induced voltage amplitude (PDMS = 1) increases to 1.070 (≈7.0%) for G/PDMS, and further to 1.0723–1.07447 (≈7.23–7.45%) for AlN–G/PDMS, BN–G/PDMS, and Si3N4-G/PDMS. DFT calculations confirm that the graphene/nitride interface has a stable structure with negative binding energies (−2.241, −1.773, and −3.062 eV for AlN–G, BN–G, and Si3N4–G, respectively). Significant charge redistribution and Mulliken charge transfer (0.0538, 0.2047, and 0.0244 eV, respectively) are present at the interface, accompanied by Fermi level density of states modulation and a small bandgap opening (~0.101 eV) in BN–G. These results collectively support the interfacial polarization-driven mechanism and provide a comparative basis for selecting nitride components in graphene-based heterojunction fillers in flexible dielectric electric field-sensing layers.

18 December 2025 in Crystals
Verified
Journal Article
Open access
PDF file
YLYuxing LEI
Yuxing LEI
BLBo Li
Bo Li
MZMengyao Zhu
Mengyao Zhu
JSJiao Sun
Jiao Sun
HYHaitao Yang
Haitao Yang
The potential of graphene for electric field sensing is limited by its zero bandgap. This study employs a combined first-principles and experimental approach to enhance its response via heterojunctions with ZnO, SnO2, and Al2O3. Calculations reveal spontaneous formation and interfacial charge transfer in all systems, with SnO2/graphene exhibiting the most significant charge transfer (0.3636 e) and inducing a finite bandgap (0.017–0.064 eV). Experimentally, SnO2-graphene/PDMS composites demonstrated the highest relative permittivity (3.19) and a 7.76% increase in normalized induced voltage over pure PDMS within 50 Hz–50 kHz. This work establishes a direct correlation between interfacial charge transfer, bandgap opening, and macroscopic dielectric enhancement, identifying SnO2/graphene as the optimal heterojunction. The integrated multi-scale methodology provides a clear design principle for high-performance, graphene-based field-sensitive materials.

4 August 2026 in Energies
Verified
Journal Article
Open access
PDF file
YLYuxing LEI
Yuxing LEI
BLBo Li
Bo Li
YYYingjie Yin
Yingjie Yin
LQLI FANG QING
LI FANG QING
JSJiao Sun
Jiao Sun
ZWzhensheng Wu
zhensheng Wu
A fault-section location method based on waveform-difference analysis of transient zero-sequence currents is proposed for distribution networks with small-current grounding systems. The method addresses weak single-phase-to-ground fault-current amplitudes, indistinct fault features, and limited adaptability of steady-state-quantity-based location criteria under arc-suppression-coil compensation. Steady-state and transient characteristics of single-phase-to-ground faults were analyzed in neutral-point ungrounded systems and arc-suppression-coil-grounded systems. Transient zero-sequence currents exhibited more pronounced amplitude, polarity, and waveform differences than steady-state zero-sequence currents, with lower sensitivity to compensation effects. These characteristics provide effective features for fault-section discrimination. The discrete Fréchet distance was used to quantify the overall waveform difference between transient zero-sequence currents at both ends of each line section. The coefficient of variation was introduced to characterize the dispersion of waveform differences among different sections. A fault-section location criterion was then constructed. The location performance was verified through PSCAD/EMTDC–MATLAB co-simulation under different neutral-point grounding modes, transition resistances, and fault inception angles. The results show that the proposed method accurately identifies fault sections and maintains good adaptability under both distinct and weak fault-feature conditions. Compared with the correlation-coefficient method, grey relational analysis, and empirical mode decomposition, the proposed method more comprehensively characterizes waveform differences in transient zero-sequence currents at both ends of a line section. It shows good section-discrimination capability under the representative fault conditions considered in this study.

9 July 2026 in Frontiers in Energy Research
Verified
Journal Article
Open access
PDF file
YMYang Minggui
Yang Minggui
ZXZhang Xindong
Zhang Xindong
YLYuxing LEI
Yuxing LEI
LBLi Bo
Li Bo
Introduction: The inconsistency between the nameplate capacity and actual rated capacity of distribution transformers poses challenges for equipment management and operation. Existing capacity detection methods generally require power outages and offline testing, limiting their applicability in practical distribution networks. To address these limitations, an online rated-capacity estimation method based on multi-sequence impedance fusion is proposed. Methods: Based on the transformer equivalent circuit and symmetrical component theory, the positive-sequence short-circuit impedance is estimated using operating voltage and current data to perform an initial capacity assessment. Considering the sensitivity of positive-sequence impedance to load imbalance, zero-sequence impedance is further introduced as supplementary validation information. By fusing positive- and zero-sequence impedance characteristics, the proposed method improves the reliability of capacity estimation under different operating conditions. Results and Discussion: Simulation studies and practical case analyses were conducted to verify the effectiveness of the proposed method. The results show that under nearly balanced three-phase operating conditions, the estimated positive-sequence impedance exhibits a strong correlation with transformer rated capacity, enabling accurate capacity identification. Under unbalanced load conditions, the introduction of zero-sequence impedance effectively compensates for the estimation bias caused by load asymmetry and improves the stability of capacity determination. The proposed method can be implemented online without power interruption, demonstrates adaptability to varying operating conditions, and exhibits good robustness and engineering applicability for distribution transformer capacity assessment.

10 April 2026 in Frontiers in Energy Research
Verified
Journal Article
Open access
PDF file
YLYuxing LEI
Yuxing LEI
BLBo Li
Bo Li
MZMeng-Meng Zhu
Meng-Meng Zhu
MYMing-Gui Yang
Ming-Gui Yang
XZXin-Dong Zhang
Xin-Dong Zhang
MZMeng-Yao Zhu
Meng-Yao Zhu
This paper proposes a method for determining the short-circuit impedance of a transformer based on data fitting techniques, which is further used to derive the transformer’s rated capacity. By establishing an equivalent circuit model and performing linear fitting on measured voltage and current data, the short-circuit impedance of three-phase distribution transformers can be calculated with reasonable accuracy. A simulation analysis is conducted on a 100 kVA dual-winding three-phase transformer. The results show that the calculated short-circuit impedance has a small error compared to the nameplate value, and the derived capacity aligns well with expectations, verifying the feasibility and accuracy of the proposed method. Compared with traditional offline testing methods, this technique does not require power outages and has the potential for online implementation. This study provides a new and effective approach for on-site identification and condition monitoring of the rated capacity of distribution transformers.