In this study, an innovative approach based on fiberoptically coupled substrate-integrated hollow waveguide (iHWG) gas cells for the analysis of low sample volumes suitable for remote broad- and narrow-band mid-infrared (MIR; 2.5–20 μm) sensing applications is reported. The feasibility of remotely addressing iHWG gas cells, configured in a double-pass geometry via a reflector, by direct coupling to a 7-around-1 mid-infrared fiber bundle is demonstrated, facilitating low-level hydrocarbon gas analysis. For comparison studies, two iHWGs with substrate dimensions of 50 × 50 × 12 mm (L × W × H) and geometric channel lengths of 138 and 58.5 mm, serving as miniature light-guiding gas cells, were fiber-coupled to a Fourier transform infrared spectrometer enabling broadband MIR sensing. In addition to the fundamental feasibility of this concept, the achievable sensitivity toward several gaseous hydrocarbons and the reproducibility of assembling the fiber-iHWG interface were investigated.
Given the exquisite capability of direct, non-destructive label-free sensing of molecular transitions, IR spectroscopy has become a ubiquitous and versatile analytical tool. IR application scenarios range from industrial manufacturing processes, surveillance tasks and environmental monitoring to elaborate evaluation of (bio)medical samples. Given recent developments in associated fields, IR spectroscopic devices increasingly evolve into reliable and robust tools for quality control purposes, for rapid analysis within at-line, in-line or on-line processes, and even for bed-side monitoring of patient health indicators. With the opportunity to guide light at or within dedicated optical structures, remote sensing as well as high-throughput sensing scenarios are being addressed by appropriate IR methodologies. In the present focused article, selected perspectives on future directions for IR spectroscopic tools and their applications are discussed. These visions are accompanied by a short introduction to the historic development, current trends, and emerging technological opportunities guiding the future path IR spectroscopy may take. Highlighted state-of-the art implementations along with novel concepts enhancing the performance of IR sensors are presented together with cutting-edge developments in related fields that drive IR spectroscopy forward in its role as a versatile analytical technology with a bright past and an even brighter future.
The identification of volatile organic compounds (VOC) such as acetone, a relevant biomarker for diabetes mellitus in exhaled human breath has become essential for early disease diagnostics, prognosis, and monitoring of metabolic responses to pharmacological interventions. Gas chromatography coupled with mass spectrometry (GC–MS) is considered as the gold standard for breath analysis. However, its inability to offer point-of-care monitoring limits its applicability in clinical environments. Optical techniques based on absorption in the mid-infrared range (2.5 to 25 μm) appear as promising alternatives due to their inherent selectivity, potential for miniaturization, portability, and direct analysis with rapid response. Relevant biomarkers present in exhaled breath, are usually observed in the ppb to ppm (v/v) concentration regime. For sensitivity enhancement of optical sensing techniques, appropriate preconcentration schemes are required prior to the optical detection. The present study describes a method combining a multi-channel substrate-integrated preconcentration module (a.k.a., muciPRECON) for enhancing and optimizing the detection of acetone via a mid-infrared photonic sensing system. The sensor system comprises a compact Fourier Transform Infrared (FTIR) spectrometer, a technique that enables detailed infrared spectral analysis, coupled to a substrate-integrated hollow waveguide (iHWG) simultaneously acting as a gas cell and as a photon conduit. Preconcentation experiments were from acetone/nitrogen gas mixtures in the concentration range of 5–100 ppm at − 10 °C followed by desorption at a temperature of 100 °C and direct injection into the IR sensing system Thus obtained acetone spectra were quantified evaluating a molecule-specific vibrational absorption peak area in the spectral window 1260–1170 cm−1. After extensive screening, Tenax was identified as superior sorbent material providing an enrichment factor of up to 153-times, a limit of detection (LOD) of 0.118 ppm, and a limit of quantification (LOQ) of 0.393 ppm. These results are indeed promising for practical applications, especially since acetone concentrations usually vary between 0.3 and 0.9 ppmv within the exhaled breath of healthy individuals, and in individuals with diabetes, acetone concentrations are typically around 1.7 to 3.0 ppmv. Consequently, the developed systems have the necessary sensitivity and accuracy to detect acetone levels that are in the relevant physiological range indicating their potential use in future real-world scenarios.