Nicusor Iftimia

Dr. Nicusor Iftimia

Physical Sciences Inc., Andover, MA, USA
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2011 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
NINicusor Iftimia
Nicusor Iftimia
Arun K. IyerArun K. Iyer
Arun K. Iyer
DHDaniel X. Hammer
Daniel X. Hammer
NLNiyom Lue
Niyom Lue
MMMircea Mujat
Mircea Mujat
MAMansoor Amiji
Mansoor Amiji
A new concept for cancer screening has been preliminarily investigated. A cancer targeting agent loaded with a near-infrared (NIR) dye was topically applied on the tissue to highlight cancer-suspect locations and guide optical coherence tomography (OCT) imaging, which was used to further investigate tissue morphology at the micron scale. A pilot study on ApcMin mice has been performed to preliminarily test this new cancer screening approach. As a cancer-targeting agent, poly(epsilon-caprolactone) microparticles (PCLMPs), labeled with a NIR dye and functionalized with an RGD (argenine-glycine-aspartic acid) peptide, were used. This agent recognizes the ανβ3 integrin receptor (ABIR), which is over-expressed by epithelial cancer cells. The contrast agent was administered topically in vivo in mouse colon. After incubation, the animals were sacrificed and fluorescence-guided high resolution optical coherence tomography (OCT) imaging was used to visualize colon morphology. The preliminary results show preferential staining of the abnormal tissue, as indicated by both microscopy and laser-induced fluorescence imaging, and OCT’s capability to differentiate between normal mucosal areas, early dysplasia, and adenocarcinoma. Although very preliminary, the results of this study suggest that fluorescence-guided OCT imaging might be a suitable approach for cancer screening. If successful, this approach could be used by clinicians to more reliably diagnose early stage cancers in vivo.

22 November 2012 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
DHDaniel X. Hammer
Daniel X. Hammer
RFR. Daniel Ferguson
R. Daniel Ferguson
MMMircea Mujat
Mircea Mujat
APAnkit Patel
Ankit Patel
EPEmily Plumb
Emily Plumb
AFAnne B. Fulton
Anne B. Fulton
Optical coherence tomography (OCT) and scanning laser ophthalmoscopy (SLO) are complementary imaging modalities, the combination of which can provide clinicians with a wealth of information to detect retinal diseases, monitor disease progression, or assess new therapies. Adaptive optics (AO) is a tool that enables correction of wavefront distortions from ocular aberrations. We have developed a multimodal adaptive optics system (MAOS) for high-resolution multifunctional use in a variety of research and clinical applications. The system integrates both OCT and SLO imaging channels into an AO beam path. The optics and hardware were designed with specific features for simultaneous SLO/OCT output, for high-fidelity AO correction, for use in humans, primates, and small animals, and for efficient location and orientation of retinal regions of interest. The MAOS system was tested on human subjects and rodents. The design, performance characterization, and initial representative results from the human and animal studies are presented and discussed.

20 August 2008 in Optics Express
Verified
Journal Article
Closed access
PDF file
NINicusor Iftimia
Nicusor Iftimia
DHDaniel X. Hammer
Daniel X. Hammer
RFR. Daniel Ferguson
R. Daniel Ferguson
MMMircea Mujat
Mircea Mujat
DVDanthu Vu
Danthu Vu
AFAnthony A. Ferrante
Anthony A. Ferrante
We have developed a dual-beam Fourier domain optical Doppler tomography (FD-ODT) system to image zebrafish (Danio rerio) larvae. Two beams incident on the zebrafish with a fixed angular separation allow absolute blood flow velocity measurement to be made regardless of vessel orientation in a sagittal plane along which the heart and most of the major vasculature lie. Two spectrometers simultaneously acquire spectra from two interferometers with a typical (maximum) line rate of 18 (28) kHz. The system was calibrated using diluted milk and microspheres and a 0.5-mm thick flow cell. The average deviation from the set velocity from 1.4 to 34.6 mm/s was 4.1%. Three-dimensional structural raster videos were acquired of an entire fish, and through the head, heart, and upper tail of the fish. Coarse features that were resolved include the telencephalon, retina, both heart chambers (atrium and ventricle), branchial arches, and notochord. Other fine structures within these organs were also resolved. Zebrafish are an important tool for high-throughput screening of new pharmacological agents. The ability to generate high-resolution three-dimensional structural videos and accurately measure absolute flow rates in major vessels with FD-ODT provides researchers with additional metrics by which the efficacy of new drugs can be assessed.

1 July 2017 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
NINicusor Iftimia
Nicusor Iftimia
OYOriol Yélamos
Oriol Yélamos
CCChih-Shan J. Chen
Chih-Shan J. Chen
GMGopi Maguluri
Gopi Maguluri
MCMiguel A. Cordova
Miguel A. Cordova
MRMilind Rajadhyaksha
Milind Rajadhyaksha
We present a hand-held implementation and preliminary evaluation of a combined optical coherence tomography (OCT) and reflectance confocal microscopy (RCM) probe for detecting and delineating the margins of basal cell carcinomas (BCCs) in human skin in vivo. A standard OCT approach (spectrometer-based) with a central wavelength of 1310 nm and 0.11 numerical aperture (NA) was combined with a standard RCM approach (830-nm wavelength and 0.9 NA) into a common path hand-held probe. Cross-sectional OCT images and enface RCM images are simultaneously displayed, allowing for three-dimensional microscopic assessment of tumor morphology in real time. Depending on the subtype and depth of the BCC tumor and surrounding skin conditions, OCT and RCM imaging are able to complement each other, the strengths of each helping overcome the limitations of the other. Four representative cases are summarized, out of the 15 investigated in a preliminary pilot study, demonstrating how OCT and RCM imaging may be synergistically combined to more accurately detect BCCs and more completely delineate margins. Our preliminary results highlight the potential benefits of combining the two technologies within a single probe to potentially guide diagnosis as well as treatment of BCCs.

8 April 2013 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
NINicusor Iftimia
Nicusor Iftimia
RFR. Daniel Ferguson
R. Daniel Ferguson
MMMircea Mujat
Mircea Mujat
APAnkit H. Patel
Ankit H. Patel
EZEllen Ziyi Zhang
Ellen Ziyi Zhang
MRMilind Rajadhyaksha
Milind Rajadhyaksha
A combined high-resolution reflectance confocal microscopy (RCM)/optical coherence tomography (OCT) instrument for assessing skin burn gravity has been built and tested. This instruments allows for visualizing skin intracellular details with submicron resolution in the RCM mode and morphological and birefringence modifications to depths on the order of 1.2 mm in the OCT mode. Preliminary testing of the dual modality imaging approach has been performed on the skin of volunteers with some burn scars and on normal and thermally-injured Epiderm FTTM skin constructs. The initial results show that these two optical technologies have complementary capabilities that can offer the clinician a set of clinically comprehensive parameters: OCT helps to visualize deeper burn injuries and possibly quantify collagen destruction by measuring skin birefringence, while RCM provides submicron details of the integrity of the epidermal layer and identifies the presence of the superficial blood flow in the upper dermis. Therefore, the combination of these two technologies within the same instrument may provide a more comprehensive set of parameters that may help clinicians to more objectively and nonivasively assess burn injury gravity by determining tissue structural integrity and viability.

1 February 2009 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
NINicusor Iftimia
Nicusor Iftimia
MMM. Mujat
M. Mujat
TUT. Ustun
T. Ustun
RFR. D. Ferguson
R. D. Ferguson
VDV. Danthu
V. Danthu
DHD. X. Hammer
D. X. Hammer
A novel technology and instrumentation for fine needle aspiration (FNA) breast biopsy guidance is presented. This technology is based on spectral-domain low coherence interferometry (SD-LCI). The method, apparatus, and preliminary in vitro/in vivo results proving the viability of the method and apparatus are presented in detail. An advanced tissue classification algorithm, preliminarily tested on breast tissue specimens and a mouse model of breast cancer is presented as well. Over 80% sensitivity and specificity in differentiating all tissue types and 93% accuracy in differentiating fatty tissue from fibrous or tumor tissue was obtained with this technology and apparatus. These results suggest that SD-LCI could help for more precise needle placement during the FNA biopsy and therefore could substantially reduce the number of the nondiagnostic aspirates and improve the sensitivity and specificity of the FNA procedures.