Marta Villalba González

Dr. Marta Villalba González

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
YJYolanda Jimenez-Gomez
Yolanda Jimenez-Gomez
DADavid Alba-Molina
David Alba-Molina
MBMario Blanco-Blanco
Mario Blanco-Blanco
LPLorena Pérez-Fajardo
Lorena Pérez-Fajardo
Felisa Reyes-OrtegaFelisa Reyes-Ortega
Felisa Reyes-Ortega
MGMiguel Gonzalez-Andrades
Miguel Gonzalez-Andrades
In recent years, the number of patients with ocular diseases is increasing as a consequence of population aging. Among them, one of the most common is the age-related macular degeneration (AMD), a condition that leads to vision loss if it is not treated. AMD is a multifactorial disorder with two advanced forms, dry and neovascular AMD. Currently, although there is no approved therapy that significantly impacts dry AMD progression, several pharmacologic therapies exist for neovascular AMD. Notwithstanding, evidence suggests a suboptimal result in a high number of patients receiving these therapeutic options. Consequently, finding effective strategies is not only a still unmet medical need in dry AMD but also in neovascular AMD. This underlines the need for new drug delivery technologies that can improve the pharmacological action and drug concentration at the target sites. In this regard, sustained drug delivery systems are presented as the most promising therapeutic options in AMD patients. This review summarized the pathogenesis and the current treatment options for AMD, focusing on the emerging ocular sustained drug delivery approaches undergoing clinical trials.

1 August 2024 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
ÁVÁlvaro Sánchez Ventosa
Álvaro Sánchez Ventosa
ACAntonio Cano-Ortiz
Antonio Cano-Ortiz
TGTimoteo González-Cruces
Timoteo González-Cruces
MGMarta Villalba González
Marta Villalba González
APAlberto Membrillo del Pozo
Alberto Membrillo del Pozo
AVAlberto Villarrubia
Alberto Villarrubia
Purpose: To evaluate the clinical outcomes of the Visian implantable collamer lens (ICL) in eyes with ≥17 years of follow-up. Setting: Single-center. Design: Retrospective observational study. Methods: 70 eyes from 38 patients who underwent surgery between 2002 and 2006 with V4 ICL implantation were analyzed. Preintervention data included corrected distance visual acuity (CDVA), refraction, and intraocular pressure (IOP). At the 19-year mark, CDVA, refraction, IOP, endothelial count, and vault were measured using Tomey Casia 2 anterior pole tomography, along with recording long-term events. Results: The operated patients had a spherical correction between −4 diopters (D) and −21 D and a cylinder up to 7.5 D. The mean CDVA (decimal) at the 17-year check-up was 0.89 ± 0.18, with a spherical equivalent of −1.05 ± 1.36 D. IOP has remained stable because mean measurements before surgery and currently were 15.16 ± 2.54 mm Hg and 16.19 ± 3.29 mm Hg, respectively. The endothelial cell count showed values of 2191 ± 386 cells/mm2, with a maximum of 2804 cells and a minimum of 1125 cells. Finally, the vault obtained was 348.53 ± 234.58 mm. Over the years, 2 eyes developed angle-closure glaucoma and 9 eyes were operated on for the development of anterior subcapsular cataracts. Conclusions: Visian ICL implantation demonstrated long-term visual and refractive stability, indicating it as a low-risk procedure. The ICL V4 model yielded satisfactory results for myopia and astigmatism correction after 17 years.

5 December 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ACAntonio Cano-Ortiz
Antonio Cano-Ortiz
ÁVÁlvaro Sánchez Ventosa
Álvaro Sánchez Ventosa
TGTimoteo González-Cruces
Timoteo González-Cruces
MGMarta Villalba González
Marta Villalba González
MPMaría Dolores López Pérez
María Dolores López Pérez
AVAlberto Villarrubia
Alberto Villarrubia
Objective: This study aimed to evaluate the initial clinical outcomes of and patient satisfaction with the newly introduced extended monofocal Evolux™ intraocular lens following cataract surgery. Methods: A retrospective study was conducted, involving 18 patients (36 eyes) who received Evolux™ lenses bilaterally. The inclusion criteria comprised individuals over 40 years old with no active eye diseases, excluding cataracts, and no postoperative complications. Various parameters were evaluated, including distance, intermediate, and near visual acuity; refraction; defocus curves; dependency on spectacles; and patient satisfaction. Patient satisfaction and visual quality of life were measured using the Catquest-9SF and QOV questionnaires. Results: The average age of the patients was 72.7 years, with the majority being women (77.8%). The results demonstrated excellent postoperative visual acuity at different distances. The mean logMAR values for uncorrected visual acuity were −0.04 for distance vision, 0.15 for intermediate vision, and 0.35 for near vision. The defocus curve indicated good tolerance, with visual acuity exceeding 20/20 in significant defocus ranges. Most patients expressed high satisfaction with their vision without spectacles, particularly for distance and intermediate vision. The need for spectacles for near vision was notably reduced. Furthermore, there was a low incidence of photic phenomena like halos and glare, contributing to the overall high patient satisfaction. Conclusions: Evolux™ lenses were found to be an effective choice for cataract surgery, providing excellent visual acuity at various distances and high patient satisfaction.

Verified
Journal Article
Open access
PDF file
ACAntonio Cano-Ortiz
Antonio Cano-Ortiz
ÁVÁlvaro Sánchez Ventosa
Álvaro Sánchez Ventosa
MGMarta Villalba González
Marta Villalba González
TGTimoteo González-Cruces
Timoteo González-Cruces
JPJuan J. Prados-Carmona
Juan J. Prados-Carmona
AVAlberto Villarrubia
Alberto Villarrubia
Background/Objectives: To evaluate the clinical and patient-reported outcomes (PROMs) obtained with an optimized version of a previously investigated trifocal IOL. Methods: Prospective non-comparative single-center study enrolling 29 patients (55–71 years) undergoing bilateral cataract surgery with implantation of the trifocal diffractive IOL Liberty 677CMY (Medicontur Medical Engineering Ltd., Zsámbék, Hungary). Visual and refractive outcomes as well as PROMs were evaluated during a 3-month follow-up: measurement of uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, DCIVA) and near visual acuities (UNVA, DCNVA), defocus curve, patient satisfaction, photic phenomena perception, spectacle independence, and difficulty in performing some vision-related activities. Results: A total of 100%, 92%, and 80% of patients achieved a postoperative binocular UDVA, UIVA, and UNVA of 20/25 or better, respectively. Likewise, 100%, 80%, and 84% of patients achieved a postoperative binocular CDVA, DCIVA, and DCNVA of 20/25 or better, respectively. In the defocus curve, all mean visual acuity values were better than 0.15 logMAR for all defocus levels. A total of 95.8%, 95.8%, and 91.7% of patients referred to be satisfied with their distance, intermediate, and near visual vision, respectively. Mean overall Catquest Rasch calibrated score was −3.12 ± 0.98. Most of the patients were spectacle independent: far (95.8%), intermediate (95.8%) or near vision (91.7%). No bothersome or minimal to moderately bothersome halo, starburst, and glare was perceived by 83.3%, 83.4%, and 83.3% of patients, respectively. Conclusions: The trifocal IOL evaluated provides a visual acuity improvement, with high levels of spectacle independence, patient satisfaction, and perceived visual quality associated.

4 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ACAntonio Cano-Ortiz
Antonio Cano-Ortiz
ÁVÁlvaro Sánchez Ventosa
Álvaro Sánchez Ventosa
VDVanesa Díaz-Mesa
Vanesa Díaz-Mesa
TGTimoteo González-Cruces
Timoteo González-Cruces
MGMarta Villalba González
Marta Villalba González
AVAlberto Villarrubia
Alberto Villarrubia
(1) Purpose: The aim was to analyze the outcomes of Descemet’s membrane endothelial keratoplasty (DMEK) and Descemet stripping only (DSO) surgeries using a glasses-assisted NGENUITY® 3D visualization system (Alcon Laboratories, Fort Worth, TX, USA). (2) Methods: Five consecutive cases of DMEK surgery and four consecutive cases of DSO were performed using the NGENUITY® system in this prospective study carried out at the Arruzafa Hospital, Córdoba, Spain. Only one eye from each patient received surgery. Best corrected distance visual acuity (CDVA) using EDTRS charts, central corneal thickness using the Casia II optical coherence tomograph (Tomey Co., Nagoya, Japan), and endothelial cell count using the Tomey EM-4000 (Tomey Co., Nagoya, Japan) for DMEK cases or the Nidek CEM-530 (Nidek Co., Ltd., Gamagori, Japan) specular microscopes for DSO cases were recorded preoperatively and at 1 and 3 months postsurgery. (3) Results: DMEK cases included one male and four female subjects, with a mean age of 73.6 ± 9.5 years. Average improvement in CDVA 3 months after surgery was 0.46 ± 0.16 decimal. Average change in cell count between 1 and 3 months postsurgery was 360.75 ± 289.38 cells/mm2. DSO cases included four female subjects, with a mean age of 64.2 ± 9.7 years. The average improvement in CDVA 3 months after surgery was 0.09 ± 0.17 decimal. All cases also had phacoemulsification carried out. He average change in cell count between 1 and 3 months after surgery was 460 ± 515.69 cells/mm2. There were no associated complications during surgery or the follow-up period in any of the cases. (4) Conclusions: In addition to the known benefits of the use of a 3D visualization system during surgery, the present study shows that the system can be successfully used in both DMEK and DSO procedures with a very short learning curve for the surgeon.

23 April 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ACAntonio Cano-Ortiz
Antonio Cano-Ortiz
ÁVÁlvaro Sánchez Ventosa
Álvaro Sánchez Ventosa
TGTimoteo González-Cruces
Timoteo González-Cruces
MGMarta Villalba González
Marta Villalba González
JPJuan J. Prados-Carmona
Juan J. Prados-Carmona
AVAlberto Villarrubia
Alberto Villarrubia
Background/Objectives: To objectively evaluate the rotational stability, refractive predictability, and visual outcomes of toric EVO ICL using automated infrared retinal retroillumination imaging. Setting/Venue: The research was conducted in a specialized ophthalmic surgery center. Design: Longitudinal analytical prospective study. Methods: The methodology included preoperative and postoperative assessments of visual acuity, subjective refraction, corneal topography, and anterior segment OCT. The implantation and alignment process utilized advanced digital centration techniques. Postoperative evaluations were conducted at 1 and 3. Results: The study found a mean incision surgically induced astigmatism (SIA) of 0.32 D, and a refractive SIA average of 2.02 D, closely matching the preoperative refractive astigmatism (target-induced astigmatism—TIA) mean of 2.07 D, resulting in a correction index (CI) of 0.96. Rotational stability was high, with 72% of lenses showing less than 5° rotation and 96% under 10° at the 1-month follow-up. No significant correlations were observed between lens rotation and postoperative vault size or horizontal compression, indicating independent factors. The discrepancy between theoretical and observed rotations suggested that the calculation method slightly underestimated actual rotation, which did not significantly affect visual outcomes. Graphical analysis demonstrated minimal impact of lens rotation on uncorrected distance visual acuity (UDVA), confirming the procedure’s efficacy and safety. Conclusions: Toric EVO ICL implants provide high rotational stability, excellent refractive predictability, and satisfactory visual outcomes. The study underscores the importance of precise implantation and the minimal influence of lens rotation on postoperative refractive errors.