Aim: The aim of this study was to share the mid-term results of percutaneous ventricular septal defect closure using Amplatzer Duct Occluder-II in children.Background: Nowadays, percutaneous ventricular septal defect closure is accepted as an alternative to surgery, but so far no ideal device has been developed for this procedure.Methods: In the study centre, between April, 2011 and October, 2016, the ventricular septal defect of 49 patients was closed percutaneously using the Amplatzer Duct Occluder-II device, and seven of them were <1 year old.Results: The mean age of patients was 86.8±52.6 months. The mean weight of the patients was 24.3±16 kg. The mean diameter of the defect was 3.7±1.4 mm. Mean fluoroscopy time and total procedure time were 37±19.3 and 74.1±27 minutes, respectively. The types of ventricular septal defects were muscular in six patients, and were perimembranous in the rest of them. We did not face any major complications during the procedure, but one patient was admitted with a complete atrioventricular block in the 6th month of follow-up. The total follow-up period was 66 months.Conclusion: To our knowledge, our study includes the largest series of paediatric patients whose ventricular septal defect was closed using Amplatzer Duct Occluder-II percutaneously. When the complications during the 66-month follow-up period are taken into consideration, we can state that Amplatzer Duct Occluder-II is a safe and effective device, even in infants aged <1 year.
Background: Traditionally the procedure of percutaneous ASD closure is carried out in children weighing more than 15 kg. The aim of this study was to discuss the success, efficacy and safety of the percutaneous closure of symptomatic ASD in children weighing less than 10 kg. Material and methods: This study was performed in two centres. A total of 44 patients were included. Demographic and angiographic data of these patients were gathered retrospectively from patients’ records. Main indications for ASD closure were: failure to thrive, recurrent respiratory infections, bronchopulmonary dysplasia and genetic syndromes. Results: Median weight of patients was 9.0(8.12–9.50) kg. Bodyweight of 22 patients was less than 3 percentiles. In the follow-up, this number was lowered to 9 patients at 12 months. Median age of patients was 18.0(12.0–285) months. Minimum age and weight of patients was 3 months and 4.5 kg, respectively. Median mean pulmonary pressure was 24.0(20.0–29.5). The values of median defect size were measured in Cath lab as 13.0(10.75–15.3) mm. Median device size was 13(9–15) mm. Defect size was evaluated according to body weight and body surface area. The ratio of weight per defect size was 0.65(0.54–0.84) also the ratio of body surface area per defect size was 0.032(0.028–0.04). The ratio of total septum per device diameter was 2.5(2.1–3.1). Types of devices used were Amplatzer Septal Occluder, Cera Flex Septal Occluder, Figulla Flex II Atrial Septal Occluder, Memopart Septal Occluder. All cases were closed successfully, but the device had to be retrieved in one patient after successful positioning because it was detected that device compressed the aorta. No major complications were seen. Conclusion: In the experienced centres, percutaneous ASD closure can be done effectively and safely in symptomatic children weighing less than 10 kg.
In this multi-centre study, the mid- to long-term efficacy and safety of the Amplatzer Piccolo Occluder in patent ductus arteriosus closure in premature and term infants as well as children were discussed. Methods. Between 2016 and 2021, 645 patients, 152 of whom were less than 1 month old, underwent ductus closure with the Piccolo device from five different centres in Turkey. The median age of the patients was 2.2 years, and the mean narrowest point of duct diameter was 1.8 mm. Sixty-two patients weighed ≤ 1.5 kg, 90 patients 1.5–3 kg, and the mean follow-up was 20.4 months. In 396, the duct was closed by the retrograde route. Ductal anatomy was Type A in 285, C in 72, E in 171, and F in 64 patients. Fluoroscopy duration was 6.2 min. The procedure success rate was 99.1%. Device embolisation occurred in 13 patients (2%), and 11 were retrieved with a snare. Cardiac perforation and death developed in one premature baby. The left pulmonary artery and the descending aorta stenosis were observed in 3 (0.4%) and in 5 patients (0.5%). Results. Piccolo device is safe and effective in closing ductus in all age groups. It has low profile for use in premature and newborn babies, a small embolisation risk, and a low residual shunt rate after closure. Conclusion. The Piccolo device can be considered as close an ideal occluder. The lower profile, smaller delivery catheter size, and symmetry of this device allow for a venous or arterial approach.