Introduction: Device closure of perimembranous ventricular septal defects (pmVSD) is a successful off-label treatment alternative. We aim to report and compare the outcomes of pmVSD closure in children weighing less than 10 kg using Amplatzer Duct Occluder II (ADOII) and Konar-MF VSD Occluder (MFO) devices.Methods: Retrospective clinical data review of 52 children with hemodynamically significant pmVSD, and sent for transcatheter closure using ADOII and MFO, between January 2018 and January 2023. Baseline, procedural, and follow-up data were compared according to the implanted deviceResults: ADOII devices were implanted in 22 children with a median age of 11 months (IQR, 4.1–14.7) and weight of 7.4 kg (IQR, 2.7–9.7). MFO devices were implanted in 30 children with a median age of 11 months (IQR, 4.8–16.6) and weight of 8 kg (IQR, 4.1–9.6). ADOII were implanted (retrograde, 68.1%) in defects with a median left ventricular diameter of 4.6 mm (IQR, 3.8–5.7) and right ventricular diameter of 3.5 mm (IQR, 3.1–4.9) while MFO were implanted (antegrade, 63.3%) in defects with a median left ventricular diameter of 7 mm (IQR, 5.2–11.3) (p > 0.05) and right ventricular diameter of 5 mm (IQR, 2.0, 3.5–6.2) (p < 0.05). The procedural and fluoroscopy times were shorter with the MFO device (p < 0.05). On a median follow-up of 41.2 months (IQR, 19.7–49.3), valvular insufficiency was not observed. One 13-month-old child (6.3 kg) with ADOII developed a complete atrioventricular heart block (CAVB) six months postoperative and required pacemaker implantation. One 11-month-old child (5.9 kg) with MFO developed a CAVB 3 days postoperative and the device was removed. At 6 months post-procedure, only one child with MFO still experiences a minor residual shunt. There was one arterio-venous fistula that resolved spontaneously.Conclusion: Both the MFO and ADOII are effective closure devices in appropriately selected pmVSDs. CAVB can occur with both devices. The MFO is inherently advantageous for defects larger than 6 mm and subaortic rims smaller than 3 mm. In the literature, our series represents the first study comparing the mid-term outcomes of MFO and ADOII devices in children weighing less than 10 kg.
In this multi-centre study, the mid- to long-term efficacy and safety of the Amplatzer Piccolo Occluder in patent ductus arteriosus closure in premature and term infants as well as children were discussed. Methods. Between 2016 and 2021, 645 patients, 152 of whom were less than 1 month old, underwent ductus closure with the Piccolo device from five different centres in Turkey. The median age of the patients was 2.2 years, and the mean narrowest point of duct diameter was 1.8 mm. Sixty-two patients weighed ≤ 1.5 kg, 90 patients 1.5–3 kg, and the mean follow-up was 20.4 months. In 396, the duct was closed by the retrograde route. Ductal anatomy was Type A in 285, C in 72, E in 171, and F in 64 patients. Fluoroscopy duration was 6.2 min. The procedure success rate was 99.1%. Device embolisation occurred in 13 patients (2%), and 11 were retrieved with a snare. Cardiac perforation and death developed in one premature baby. The left pulmonary artery and the descending aorta stenosis were observed in 3 (0.4%) and in 5 patients (0.5%). Results. Piccolo device is safe and effective in closing ductus in all age groups. It has low profile for use in premature and newborn babies, a small embolisation risk, and a low residual shunt rate after closure. Conclusion. The Piccolo device can be considered as close an ideal occluder. The lower profile, smaller delivery catheter size, and symmetry of this device allow for a venous or arterial approach.
Introduction: With the development of transcatheter interventional techniques and the introduction of next-generation duct occluder devices, transcatheter closure has become the first treatment option for patent ductus arteriosus (PDA) in pediatric patients. In this study, we compared the effectiveness and safety of different devices for transcatheter PDA closure in pediatric patients, focusing on long-term outcomes. Methods: A total of 235 patients aged 0-18 years who underwent transcatheter PDA closure at a tertiary care center between January 2005 and February 2020 were included. The medical records of the cases were retrospectively evaluated. Results: The median age of the patients was 2.3 years (range: 3.5 months to 17 years), with a mean weight of 12.8 kg (range: 5.7-43.2 kg). The mean PDA diameter at its narrowest point was 2.9 mm (range: 2.2-5.1 mm). Ductal anatomy was as follows: Type A in 98 (41.7%) patients, Type E in 36 (15.6%) patients, Type C in 32 (13.5%) patients, Type F in 27 (11.4%) patients, Type D in 23 (9.7%) patients, and Type B in 19 (8.1%) patients. Arterial access was used in 138 (57.1%) patients, venous + arterial access in 58 (24.6%) patients, and venous access only in 39 (16.5%) patients. Closure was performed with Amplatzer Duct Occluder (ADO; AGA Medical Corp., Golden Valley, MN, USA) II in 151 (64.2%) cases, ADO I in 43 (18.2%) cases, and coils in 41 (17.4%) cases. The mean fluoroscopy time and mean procedural time were 10.3 ± 4.2 minutes and 41 ± 7.2 minutes, respectively. The mean radiation dose was 1364 ± 497 cGy/min. The early closure rate after the procedure was 92%, while residual shunting on the first day post-procedure was observed in 1.8% of cases, decreasing to 0.1% at the one-month follow-up. The overall procedural success rate for all cases was 96.0%. The mean follow-up duration was 9.7 years (range: 2.9-13.8 years). Conclusion: For percutaneous PDA closure, ADO I devices are preferred for larger defects, whereas ADO II devices are prioritized for small- to medium-sized defects instead of coils.
Ectopia cordis is a rare congenital disorder in which the heart is partially or completely located outside the chest cavity. In this article, we present four cases of ectopia cordis accompanied by cardiac abnormalities with either thoracic and/or abdominal placed heart, managed with strategies ranging from follow-up without any intervention to complete surgical closure.