In recent years, there has been growing interest in postural monitoring while seated, thus preventing the appearance of ulcers and musculoskeletal problems in the long term. To date, postural control has been carried out by means of subjective questionnaires that do not provide continuous and quantitative information. For this reason, it is necessary to carry out a monitoring that allows to determine not only the postural status of wheelchair users, but also to infer the evolution or anomalies associated with a specific disease. Therefore, this paper proposes an intelligent classifier based on a multilayer neural network for the classification of sitting postures of wheelchair users. The posture database was generated based on data collected by a novel monitoring device composed of force resistive sensors. A training and hyperparameter selection methodology has been used based on the idea of using a stratified K-Fold in weight groups strategy. This allows the neural network to acquire a greater capacity for generalization, thus allowing, unlike other proposed models, to achieve higher success rates not only in familiar subjects but also in subjects with physical complexions outside the standard. In this way, the system can be used to support wheelchair users and healthcare professionals, helping them to automatically monitor their posture, regardless physical complexions.
In order to properly control rehabilitation robotic devices, the measurement of interaction force and motion between patient and robot is an essential part. Usually, however, this is a complex task that requires the use of accurate sensors which increase the cost and the complexity of the robotic device. In this work, we address the development of virtual sensors that can be used as an alternative of actual force and motion sensors for the Universal Haptic Pantograph (UHP) rehabilitation robot for upper limbs training. These virtual sensors estimate the force and motion at the contact point where the patient interacts with the robot using the mathematical model of the robotic device and measurement through low cost position sensors. To demonstrate the performance of the proposed virtual sensors, they have been implemented in an advanced position/force controller of the UHP rehabilitation robot and experimentally evaluated. The experimental results reveal that the controller based on the virtual sensors has similar performance to the one using direct measurement (less than 0.005 m and 1.5 N difference in mean error). Hence, the developed virtual sensors to estimate interaction force and motion can be adopted to replace actual precise but normally high-priced sensors which are fundamental components for advanced control of rehabilitation robotic devices.
The control of flexible link parallel manipulators is still an open area of research, endpoint trajectory tracking being one of the main challenges in this type of robot. The flexibility and deformations of the limbs make the estimation of the Tool Centre Point (TCP) position a challenging one. Authors have proposed different approaches to estimate this deformation and deduce the location of the TCP. However, most of these approaches require expensive measurement systems or the use of high computational cost integration methods. This work presents a novel approach based on a virtual sensor which can not only precisely estimate the deformation of the flexible links in control applications (less than 2% error), but also its derivatives (less than 6% error in velocity and 13% error in acceleration) according to simulation results. The validity of the proposed Virtual Sensor is tested in a Delta Robot, where the position of the TCP is estimated based on the Virtual Sensor measurements with less than a 0.03% of error in comparison with the flexible approach developed in ADAMS Multibody Software.