Masudul Imtiaz

Dr. Masudul Imtiaz


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AAAnika Alim
Anika Alim
MIMasudul Imtiaz
Masudul Imtiaz
Maternal health includes health during pregnancy and childbirth. Each stage during pregnancy should be a positive experience, ensuring that women and their babies reach their full potential in health and well-being. However, this cannot always be achieved. According to UNFPA (United Nations Population Fund), approximately 800 women die every day from avoidable causes related to pregnancy and childbirth, so it is important to monitor mother and fetal health throughout the pregnancy. Many wearable sensors and devices have been developed to monitor both fetal and the mother’s health and physical activities and reduce risk during pregnancy. Some wearables monitor fetal ECG or heart rate and movement, while others focus on the mother’s health and physical activities. This study presents a systematic review of these analyses. Twelve scientific articles were reviewed to address three research questions oriented to (1) sensors and method of data acquisition; (2) processing methods of the acquired data; and (3) detection of the activities or movements of the fetus or the mother. Based on these findings, we discuss how sensors can help effectively monitor maternal and fetal health during pregnancy. We have observed that most of the wearable sensors were used in a controlled environment. These sensors need more testing in free-living conditions and to be employed for continuous monitoring before being recommended for mass implementation.

21 February 2023 in Signals
Verified
Journal Article
Open access
PDF file
AAAnika Alim
Anika Alim
MIMasudul Imtiaz
Masudul Imtiaz
EEG (electroencephalogram) signals could be used reliably to extract critical information regarding ADHD (attention deficit hyperactivity disorder), a childhood neurodevelopmental disorder. The early detection of ADHD is important to lessen the development of this disorder and reduce its long-term impact. This study aimed to develop a computer algorithm to identify children with ADHD automatically from the characteristic brain waves. An EEG machine learning pipeline is presented here, including signal preprocessing and data preparation steps, with thorough explanations and rationale. A large public dataset of 120 children was selected, containing large variability and minimal measurement bias in data collection and reproducible child-friendly visual attentional tasks. Unlike other studies, EEG linear features were extracted to train a Gaussian SVM-based model from only the first four sub-bands of EEG. This eliminates signals more than 30 Hz, thus reducing the computational load for model training while keeping mean accuracy of ~94%. We also performed rigorous validation (obtained 93.2% and 94.2% accuracy, respectively, for holdout and 10-fold cross-validation) to ensure that the developed model is minimally impacted by bias and overfitting that commonly appear in the ML pipeline. These performance metrics indicate the ability to automatically identify children with ADHD from a local clinical setting and provide a baseline for further clinical evaluation and timely therapeutic attempts.

Verified
Journal Article
Open access
PDF file
ACA M MAHMUD CHOWDHURY
A M MAHMUD CHOWDHURY
MIMasudul Imtiaz
Masudul Imtiaz
Contactless fingerprint identification systems have been introduced to address the deficiencies of contact-based fingerprint systems. A number of studies have been reported regarding contactless fingerprint processing, including classical image processing, the machine-learning pipeline, and a number of deep-learning-based algorithms. The deep-learning-based methods were reported to have higher accuracies than their counterparts. This study was thus motivated to present a systematic review of these successes and the reported limitations. Three methods were researched for this review: (i) the finger photo capture method and corresponding image sensors, (ii) the classical preprocessing method to prepare a finger image for a recognition task, and (iii) the deep-learning approach for contactless fingerprint recognition. Eight scientific articles were identified that matched all inclusion and exclusion criteria. Based on inferences from this review, we have discussed how deep learning methods could benefit the field of biometrics and the potential gaps that deep-learning approaches need to address for real-world biometric applications.
1

6 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MSMD ABDUL BASET SARKER
MD ABDUL BASET SARKER
MIMasudul Imtiaz
Masudul Imtiaz
THThomas Holsen
Thomas Holsen
Abul BakiAbul Baki
Abul Baki
Microplastics (MPs, size ≤ 5 mm) have emerged as a significant worldwide concern, threatening marine and freshwater ecosystems, and the lack of MP detection technologies is notable. The main goal of this research is the development of a camera sensor for the detection of MPs and measuring their size and velocity while in motion. This study introduces a novel methodology involving computer vision and artificial intelligence (AI) for the detection of MPs. Three different camera systems, including fixed-focus 2D and autofocus (2D and 3D), were implemented and compared. A YOLOv5-based object detection model was used to detect MPs in the captured image. DeepSORT was then implemented for tracking MPs through consecutive images. In real-time testing in a laboratory flume setting, the precision in MP counting was found to be 97%, and during field testing in a local river, the precision was 96%. This study provides foundational insights into utilizing AI for detecting MPs in different environmental settings, contributing to more effective efforts and strategies for managing and mitigating MP pollution.

29 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Volkan SenyurekVolkan Senyurek
Volkan Senyurek
MIMasudul Imtiaz
Masudul Imtiaz
PBPrajakta Belsare
Prajakta Belsare
STStephen Tiffany
Stephen Tiffany
Edward SazonovEdward Sazonov
Edward Sazonov
In recent years, a number of wearable approaches have been introduced for objective monitoring of cigarette smoking based on monitoring of hand gestures, breathing or cigarette lighting events. However, non-reactive, objective and accurate measurement of everyday cigarette consumption in the wild remains a challenge. This study utilizes a wearable sensor system (Personal Automatic Cigarette Tracker 2.0, PACT2.0) and proposes a method that integrates information from an instrumented lighter and a 6-axis Inertial Measurement Unit (IMU) on the wrist for accurate detection of smoking events. The PACT2.0 was utilized in a study of 35 moderate to heavy smokers in both controlled (1.5–2 h) and unconstrained free-living conditions (~24 h). The collected dataset contained approximately 871 h of IMU data, 463 lighting events, and 443 cigarettes. The proposed method identified smoking events from the cigarette lighter data and estimated puff counts by detecting hand-to-mouth gestures (HMG) in the IMU data by a Support Vector Machine (SVM) classifier. The leave-one-subject-out (LOSO) cross-validation on the data from the controlled portion of the study achieved high accuracy and F1-score of smoking event detection and estimation of puff counts (97%/98% and 93%/86%, respectively). The results of validation in free-living demonstrate 84.9% agreement with self-reported cigarettes. These results suggest that an IMU and instrumented lighter may potentially be used in studies of smoking behavior under natural conditions.

28 November 2017 in Electronics
Verified
Journal Article
Open access
PDF file
MIMasudul Imtiaz
Masudul Imtiaz
RRRaul I. Ramos-Garcia
Raul I. Ramos-Garcia
Volkan SenyurekVolkan Senyurek
Volkan Senyurek
STStephen Tiffany
Stephen Tiffany
Edward SazonovEdward Sazonov
Edward Sazonov
This paper presents the development and validation of a novel multi-sensory wearable system (Personal Automatic Cigarette Tracker v2 or PACT2.0) for monitoring of cigarette smoking in free-living conditions. The contributions of the PACT2.0 system are: (1) the implementation of a complete sensor suite for monitoring of all major behavioral manifestations of cigarette smoking (lighting events, hand-to-mouth gestures, and smoke inhalations); (2) a miniaturization of the sensor hardware to enable its applicability in naturalistic settings; and (3) an introduction of new sensor modalities that may provide additional insight into smoking behavior e.g., Global Positioning System (GPS), pedometer and Electrocardiogram(ECG) or provide an easy-to-use alternative (e.g., bio-impedance respiration sensor) to traditional sensors. PACT2.0 consists of three custom-built devices: an instrumented lighter, a hand module, and a chest module. The instrumented lighter is capable of recording the time and duration of all lighting events. The hand module integrates Inertial Measurement Unit (IMU) and a Radio Frequency (RF) transmitter to track the hand-to-mouth gestures. The module also operates as a pedometer. The chest module monitors the breathing (smoke inhalation) patterns (inductive and bio-impedance respiratory sensors), cardiac activity (ECG sensor), chest movement (three-axis accelerometer), hand-to-mouth proximity (RF receiver), and captures the geo-position of the subject (GPS receiver). The accuracy of PACT2.0 sensors was evaluated in bench tests and laboratory experiments. Use of PACT2.0 for data collection in the community was validated in a 24 h study on 40 smokers. Of 943 h of recorded data, 98.6% of the data was found usable for computer analysis. The recorded information included 549 lighting events, 522/504 consumed cigarettes (from lighter data/self-registered data, respectively), 20,158/22,207 hand-to-mouth gestures (from hand IMU/proximity sensor, respectively) and 114,217/112,175 breaths (from the respiratory inductive plethysmograph (RIP)/bio-impedance sensor, respectively). The proposed system scored 8.3 ± 0.31 out of 10 on a post-study acceptability survey. The results suggest that PACT2.0 presents a reliable platform for studying of smoking behavior at the community level.