Jing Yuan

Dr. Jing Yuan

Research Department, Hong Kong Sanatorium & Hospital, Happy Valley, Hong Kong SAR, China
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
CXCindy Xue
Cindy Xue
JYJing Yuan
Jing Yuan
GLGladys G. Lo
Gladys G. Lo
ACAmy T. Y. Chang
Amy T. Y. Chang
DPDarren M. C. Poon
Darren M. C. Poon
WCWinnie C. W. Chu
Winnie C. W. Chu
Radiomics feature reliability assessed by intraclass correlation coefficient: a systematic review Cindy Xue, Jing Yuan, Gladys G. Lo, Amy T. Y. Chang, Darren M. C. Poon, Oi Lei Wong, Yihang Zhou, Winnie C. W. Chu

23 January 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JYJing Yuan
Jing Yuan
DYDavid Ka Wai Yeung
David Ka Wai Yeung
GMGreta S. P. Mok
Greta S. P. Mok
KBKunwar S. Bhatia
Kunwar S. Bhatia
Yi-Xiang WangYi-Xiang Wang
Yi-Xiang Wang
AKAnn D. King
Ann D. King
To technically investigate the non-Gaussian diffusion of head and neck diffusion weighted imaging (DWI) at 3 Tesla and compare advanced non-Gaussian diffusion models, including diffusion kurtosis imaging (DKI), stretched-exponential model (SEM), intravoxel incoherent motion (IVIM) and statistical model in the patients with nasopharyngeal carcinoma (NPC). After ethics approval was granted, 16 patients with NPC were examined using DWI performed at 3T employing an extended b-value range from 0 to 1500 s/mm2. DWI signals were fitted to the mono-exponential and non-Gaussian diffusion models on primary tumor, metastatic node, spinal cord and muscle. Non-Gaussian parameter maps were generated and compared to apparent diffusion coefficient (ADC) maps in NPC. Diffusion in NPC exhibited non-Gaussian behavior at the extended b-value range. Non-Gaussian models achieved significantly better fitting of DWI signal than the mono-exponential model. Non-Gaussian diffusion coefficients were substantially different from mono-exponential ADC both in magnitude and histogram distribution. Non-Gaussian diffusivity in head and neck tissues and NPC lesions could be assessed by using non-Gaussian diffusion models. Non-Gaussian DWI analysis may reveal additional tissue properties beyond ADC and holds potentials to be used as a complementary tool for NPC characterization.

19 August 2014 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
JYJing Yuan
Jing Yuan
SCShuzhong Chen
Shuzhong Chen
AKAnn D. King
Ann D. King
JZJinyuan Zhou
Jinyuan Zhou
KBKunwar S. Bhatia
Kunwar S. Bhatia
Yi-Xiang WangYi-Xiang Wang
Yi-Xiang Wang

5 May 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
BLB.K.H. Law
B.K.H. Law
AKAnn D. King
Ann D. King
KBK.S. Bhatia
K.S. Bhatia
AAA.T. Ahuja
A.T. Ahuja
MKM.K.M. Kam
M.K.M. Kam
DYDavid K W Yeung
David K W Yeung
BACKGROUND AND PURPOSE: Pretreatment prediction of patients with nasopharyngeal carcinoma who will fail conventional treatment would potentially allow these patients to undergo more intensive treatment or closer posttreatment monitoring. The aim of the study was to determine the ability of pretreatment DWI to predict local failure in patients with nasopharyngeal carcinoma based on long-term clinical outcome. MATERIALS AND METHODS: One hundred fifty-eight patients with pretreatment DWI underwent analysis of the primary tumor to obtain the ADC mean, ADC skewness, ADC kurtosis, volume, and T-stage. Univariate and multivariate analyses using logistic regression were performed to compare the ADC parameters, volume, T-stage, and patient age in primary tumors with local failure and those with local control, by using a minimum of 5-year follow-up to confirm local control. RESULTS: Local control was achieved in 131/158 (83%) patients (range, 60.3–117.7 months) and local failure occurred in 27/158 (17%) patients (range, 5.2–79.8 months). Compared with tumors with local control, those with local failure showed a significantly lower ADC skewness (ADC values with the greatest frequencies were shifted away from the lower ADC range) (P = .006) and lower ADC kurtosis (curve peak broader) (P = .024). The ADC skewness remained significant on multivariate analysis (P = .044). There was a trend toward higher tumor volumes in local failure, but the volume, together with T-stage and ADC mean, were not significantly different between the 2 groups. CONCLUSIONS: Pretreatment DWI of primary tumors found that the skewness of the ADC distribution curve was a predictor of local failure in patients with nasopharyngeal carcinoma, based on long-term clinical outcome.

1 July 2019 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Closed access
JYJing Yuan
Jing Yuan
OWOi Lei Wong
Oi Lei Wong
YZYihang Zhou
Yihang Zhou
KCKin Yin Chueng
Kin Yin Chueng
SYSiu Ki Yu
Siu Ki Yu
To propose a fast volumetric 4D-MRI based on 3D pulse sequence acquisition for abdominal motion monitoring and characterization in MRI-guided radiotherapy (MRgRT). A 3D spoiled gradient echo sequence volumetric interpolated breath-hold examination (VIBE) [repetition time/echo time (TR/TE) =0.53/1.57 ms, flip-angle =5°, receiver bandwidth (RBW) =1,400 Hz/voxel] based 4D-MRI acquisition, accelerated by 4-fold controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA), named CAIPIRINHA-VIBE 4D-MRI, was implemented on a 1.5T MRI simulator (MR-sim) and applied for abdominal imaging of nine healthy volunteers under free breathing. One hundred and forty-four dynamics of the entire abdomen volume (56 slices), in total 8,064 (144×56) images with a voxel size of 2.7×2.7×4.0 mm3, were acquired in 89 s for 4D-MRI. This CAIPIRINHA-VIBE 4D-MRI was qualitatively compared with a 2D half-Fourier acquisition single-shot turbo spin-echo (2D-HASTE) based 4D-MRI. The motions of liver dome, kidney and spleen were analyzed using the CAIPIRINHA-VIBE 4D-MRI data. The kidney motion was quantitatively characterized in terms of motion range and the correlations between left and right kidneys. CAIPIRINHA-VIBE 4D-MRI was successfully conducted in all subjects. CAIPIRINHA-VIBE 4D-MRI exhibited much higher effective volumetric temporal resolution (0.615 vs. ~5 s/volume) and better reconstructed volume consistency than 2D-HASTE 4D-MRI. CAIPIRINHA-VIBE 4D-MRI was able to characterize the respiratory motion of abdominal organs simultaneously in three orthogonal directions, and could potentially be used for whole abdomen deformable motion tracking. Renal motion range was most pronounced in superior-inferior (SI) direction (L: 10.03±2.65 mm; R: 10.38±2.80 mm), significantly larger (P<0.001) than that in anterior-posterior (AP) and the least in left-right (LR) directions. Right kidney had significantly larger mobility (4.18±2.19 vs. 2.32±1.34 mm, P=0.045) than left kidney in AP, but not in LR and SI directions. The Pearson correlation coefficients r between left and right kidney motion were 0.5063 (P=0.164), 0.6624 (P=0.052) and 0.5752 (P=0.105) in LR, AP and SI correspondingly. The correlation of renal motion in SI and AP was found significant in right kidney (r=0.843, P=0.004) but not in left kidney (r=0.467, P=0.205). A fast volumetric 4D-MRI was implemented for abdominal motion monitoring in MRgRT. A sub-second volumetric temporal resolution of 0.615 s, covering the entire abdomen, was demonstrated for respiratory motion monitoring and characterization. This technique holds potentials for MRgRT applications.

17 February 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CMChang‐Sheng Mei
Chang‐Sheng Mei
LPLawrence P. Panych
Lawrence P. Panych
JYJing Yuan
Jing Yuan
NMNathan J. McDannold
Nathan J. McDannold
LTLisa H. Treat
Lisa H. Treat
BMBruno Madore
Bruno Madore
MR thermometry can be a very challenging application, as good resolution may be needed along spatial, temporal, and temperature axes. Given that the heated foci produced during thermal therapies are typically much smaller than the anatomy being imaged, much of the imaged field‐of‐view is not actually being heated and may not require temperature monitoring. In this work, many‐fold improvements were obtained in terms of temporal resolution and/or 3D spatial coverage by sacrificing some of the in‐plane spatial coverage. To do so, three fast‐imaging approaches were jointly implemented with a spoiled gradient echo sequence: (1) two‐dimensional spatially selective RF excitation, (2) unaliasing by Fourier encoding the overlaps using the temporal dimension (UNFOLD), and (3) parallel imaging. The sequence was tested during experiments with focused ultrasound heating in ex vivo tissue and a tissue‐mimicking phantom. Temperature maps were estimated from phase‐difference images based on the water proton resonance frequency shift. Results were compared to those obtained from a spoiled gradient echo sequence sequence, using a t‐test. Temporal resolution was increased by 24‐fold, with temperature uncertainty less than 1°C, while maintaining accurate temperature measurements (mean difference between measurements, as observed in gel = 0.1°C ± 0.6; R = 0.98; P > 0.05). Magn Reson Med 66:112–122, 2011.