Bruno Madore

Bruno Madore

Auto-generated profile, based on publicly available information

Bruno Madore

Department of Radiology Mass General Brigham, Harvard Medical School Boston Massachusetts USA

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Radiology
Verified
Journal Article
Closed access
HHHiroto Hatabu
Hiroto Hatabu
YOYoshiharu Ohno
Yoshiharu Ohno
WGWarren B. Gefter
Warren B. Gefter
GPGrace Parraga
Grace Parraga
BMBruno Madore
Bruno Madore
FSFor The Fleischner Society
For The Fleischner Society
Due to technical advances in pulmonary MRI, the Fleischner Society offers its consensus recommendations for the clinical use of MRI in evaluating patients with common lung disorders. Pulmonary MRI provides structural and quantitative functional images of the lungs without ionizing radiation, but it has had limited clinical use due to low signal intensity from the lung parenchym...

23 July 2004 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
BMBruno Madore
Bruno Madore
This work aims at improving the performance of parallel imaging by using it with our “unaliasing by Fourier‐encoding the overlaps in the temporal dimension” (UNFOLD) temporal strategy. A self‐calibration method called “self, hybrid referencing with UNFOLD and GRAPPA” (SHRUG) is presented. SHRUG combines the UNFOLD‐based sensitivity mapping strategy introduced in the TSENSE method by Kellman et al. (5), with the strategy introduced in the GRAPPA method by Griswold et al. (10). SHRUG merges the two approaches to alleviate their respective limitations, and provides fast self‐calibration at any given acceleration factor. UNFOLD‐SENSE further includes an UNFOLD artifact suppression scheme to significantly suppress artifacts and amplified noise produced by parallel imaging. This suppression scheme, which was published previously (4), is related to another method that was presented independently as part of TSENSE. While the two are equivalent at accelerations ≤ 2.0, the present approach is shown here to be significantly superior at accelerations > 2.0, with up to double the artifact suppression at high accelerations. Furthermore, a slight modification of Cartesian SENSE is introduced, which allows departures from purely Cartesian sampling grids. This technique, termed variable‐density SENSE (vdSENSE), allows the variable‐density data required by SHRUG to be reconstructed with the simplicity and fast processing of Cartesian SENSE. UNFOLD‐SENSE is given by the combination of SHRUG for sensitivity mapping, vdSENSE for reconstruction, and UNFOLD for artifact/amplified noise suppression. The method was implemented, with online reconstruction, on both an SSFP and a myocardium‐perfusion sequence. The results from six patients scanned with UNFOLD‐SENSE are presented. Magn Reson Med 52:310–320, 2004.

23 August 2002 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
BMBruno Madore
Bruno Madore
In dynamic MRI, it is often difficult to achieve the acquisition speed required to resolve or freeze the temporal variations of the imaged object. Several MRI methods aim at speeding up the image acquisition process. Through assumptions and/or prior knowledge, these dynamic MRI methods allow part of the needed data to be calculated instead of acquired. For example, partial‐Fourier imaging assumes that phase varies smoothly within the object, and parallel imaging (e.g., simultaneous acquisition of spatial harmonics (SMASH) and sensitivity encoding (SENSE)) uses prior knowledge about receiver‐coil sensitivity. While these methods accelerate acquisition, they can introduce artifacts or amplify noise in doing so. The present work aims at accelerating image acquisition significantly, while introducing almost no artifacts or noise amplification. It is shown here that new, extra information is gained if dynamic MRI methods are modified so that the sampling function changes in specific ways from time‐frame to time‐frame. In other words, the set of k‐space locations that are acquired (instead of calculated) changes with time. The present temporal strategy, based on the UNaliasing by Fourier‐encoding the Overlaps in the temporaL Dimension (UNFOLD) method, can be incorporated into common dynamic MRI methods. Results with partial‐Fourier, SMASH, and SENSE imaging are presented here, where UNFOLD's contribution is to very significantly reduce the artifact and/or amplified noise content. Used in this way, UNFOLD contributes indirectly, rather than directly to the improvement in image acquisition speed, as it allows companion methods to operate properly at greater acceleration settings than would otherwise be feasible. Magn Reson Med 48:493–501, 2002.

23 May 2001 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
BMBruno Madore
Bruno Madore
NPNorbert J. Pelc
Norbert J. Pelc
Three parallel‐imaging methods were implemented and compared in terms of artifact and noise content: original SMASH, Cartesian SENSE, and an extremely simple method called here the “scissors method.” These methods represent very different approaches to the parallel‐imaging problem. The experimental and numerical comparisons presented here aim at shedding light on the whole spectrum of parallel‐imaging methods, not just the three methods actually implemented. In our results, SMASH images had an artifact level significantly higher than SENSE images for all acceleration factors. The SNR in SENSE images was nearly optimal at low acceleration factors. As acceleration was increased, the noise content in SENSE images eventually sharply departed from optimal values, while the artifact content remained low. Magn Reson Med 45:1103–1111, 2001.

17 February 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CMChang‐Sheng Mei
Chang‐Sheng Mei
LPLawrence P. Panych
Lawrence P. Panych
JYJing Yuan
Jing Yuan
NMNathan J. McDannold
Nathan J. McDannold
LTLisa H. Treat
Lisa H. Treat
BMBruno Madore
Bruno Madore
MR thermometry can be a very challenging application, as good resolution may be needed along spatial, temporal, and temperature axes. Given that the heated foci produced during thermal therapies are typically much smaller than the anatomy being imaged, much of the imaged field‐of‐view is not actually being heated and may not require temperature monitoring. In this work, many‐fold improvements were obtained in terms of temporal resolution and/or 3D spatial coverage by sacrificing some of the in‐plane spatial coverage. To do so, three fast‐imaging approaches were jointly implemented with a spoiled gradient echo sequence: (1) two‐dimensional spatially selective RF excitation, (2) unaliasing by Fourier encoding the overlaps using the temporal dimension (UNFOLD), and (3) parallel imaging. The sequence was tested during experiments with focused ultrasound heating in ex vivo tissue and a tissue‐mimicking phantom. Temperature maps were estimated from phase‐difference images based on the water proton resonance frequency shift. Results were compared to those obtained from a spoiled gradient echo sequence sequence, using a t‐test. Temporal resolution was increased by 24‐fold, with temperature uncertainty less than 1°C, while maintaining accurate temperature measurements (mean difference between measurements, as observed in gel = 0.1°C ± 0.6; R = 0.98; P > 0.05). Magn Reson Med 66:112–122, 2011.

9 March 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
BMBruno Madore
Bruno Madore
LPLawrence P. Panych
Lawrence P. Panych
CMChang‐Sheng Mei
Chang‐Sheng Mei
JYJing Yuan
Jing Yuan
RCRenxin Chu
Renxin Chu
MR‐based thermometry is a valuable adjunct to thermal ablation therapies as it helps to determine when lethal doses are reached at the target and whether surrounding tissues are safe from damage. When the targeted lesion is mobile, MR data can further be used for motion‐tracking purposes. The present work introduces pulse sequence modifications that enable significant improvements in terms of both temperature‐to‐noise‐ratio properties and target‐tracking abilities. Instead of sampling a single magnetization pathway as in typical MR thermometry sequences, the pulse‐sequence design introduced here involves sampling at least one additional pathway. Image reconstruction changes associated with the proposed sampling scheme are also described. The method was implemented on two commonly used MR thermometry sequences: the gradient‐echo and the interleaved echo‐planar imaging sequences. Data from the extra pathway enabled temperature‐to‐noise‐ratio improvements by up to 35%, without increasing scan time. Potentially of greater significance is that the sampled pathways featured very different contrast for blood vessels, facilitating their detection and use as internal landmarks for tracking purposes. Through improved temperature‐to‐noise‐ratio and lesion‐tracking abilities, the proposed pulse‐sequence design may facilitate the use of MR‐monitored thermal ablations as an effective treatment option even in mobile organs such as the liver and kidneys. Magn Reson Med, 2011.