Marcel Nachbar

Dr. Marcel Nachbar

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Radiotherapy and Oncology
Verified
Journal Article
Open access
LKLuise A. Künzel
Luise A. Künzel
MNMarcel Nachbar
Marcel Nachbar
MHMarkus Hagmüller
Markus Hagmüller
CGCihan Gani
Cihan Gani
SBSimon Boeke
Simon Boeke
DTDaniela Thorwarth
Daniela Thorwarth
Currently clinical radiotherapy (RT) planning consists of a multi-step routine procedure requiring human interaction which often results in a time-consuming and fragmented process with limited robustness. Here we present an autonomous un-supervised treatment planning approach, integrated as basis for online adaptive magnetic resonance guided RT (MRgRT), which was delivered to a prostate cancer patient as a first-in-human experience. For an intermediate risk prostate cancer patient OARs and targets were automatically segmented using a deep learning-based software and logical volume operators. A baseline plan for the 1.5 T MR-Linac (20x3 Gy) was automatically generated using particle swarm optimization (PSO) without any human interaction. Plan quality was evaluated by predefined dosimetric criteria including appropriate tolerances. Online plan adaptation during clinical MRgRT was defined as first checkpoint for human interaction. OARs and targets were successfully segmented (3 min) and used for automatic plan optimization (300 min). The autonomous generated plan satisfied 12/16 dosimetric criteria, however all remained within tolerance. Without prior human validation, this baseline plan was successfully used during online MRgRT plan adaptation, where 14/16 criteria were fulfilled. As postulated, human interaction was necessary only during plan adaptation. Autonomous, un-supervised data preparation and treatment planning was first-in-human shown to be feasible for adaptive MRgRT and successfully applied. The checkpoint for first human intervention was at the time of online MRgRT plan adaptation. Autonomous planning reduced the time delay between simulation and start of RT and may thus allow for real-time MRgRT applications in the future.

26 March 2021 in Cancers
Verified
Journal Article
Open access
PDF file
HAHaidara Almansour
Haidara Almansour
Saif AfatSaif Afat
Saif Afat
VFVictor Fritz
Victor Fritz
FSFritz Schick
Fritz Schick
MNMarcel Nachbar
Marcel Nachbar
DWDaniel Wegener
Daniel Wegener
The objective of this study is to conduct a qualitative and a quantitative image quality and lesion evaluation in patients undergoing MR-guided radiation therapy (MRgRT) for prostate cancer on a hybrid magnetic resonance imaging and linear accelerator system (MR-Linac or MRL) at 1.5 Tesla. This prospective study was approved by the institutional review board. A total of 13 consecutive patients with biopsy-confirmed prostate cancer and an indication for MRgRT were included. Prior to radiation therapy, each patient underwent an MR-examination on an MRL and on a standard MRI scanner at 3 Tesla (MRI3T). Three readers (two radiologists and a radiation oncologist) conducted an independent qualitative and quantitative analysis of T2-weighted (T2w) and diffusion-weighted images (DWI). Qualitative outcome measures were as follows: zonal anatomy, capsule demarcation, resolution, visibility of the seminal vesicles, geometric distortion, artifacts, overall image quality, lesion conspicuity, and diagnostic confidence. All ratings were performed on an ordinal 4-point Likert scale. Lesion conspicuity and diagnostic confidence were firstly analyzed only on MRL. Afterwards, these outcome parameters were analyzed in consensus with the MRI3T. Quantitative outcome measures were as follows: anteroposterior and right left diameter of the prostate, lesion size, PI-RADS score (Prostate Imaging—Reporting and Data System) and apparent diffusion coefficient (ADC) of the lesions. Intergroup comparisons were computed using the Wilcoxon-sign rank test and t tests. A post-hoc regression analysis was computed for lesion evaluation. Finally, inter-/intra-reader agreement was analyzed using the Fleiss kappa and intraclass correlation coefficient. For T2w images, the MRL showed good results across all quality criteria (median 3 and 4). Furthermore, there were no significant differences between MRL and MRI3T regarding capsule demarcation or geometric distortion. For the DWI, the MRL performed significantly less than MRI3T across most image quality criteria with a median ranging between 2 and 3. However, there were no significant differences between MRL and MRI3T regarding geometric distortion. In terms of lesion conspicuity and diagnostic confidence, inter-reader agreement was fair for MRL alone (Kappa = 0.42) and good for MRL in consensus with MRI3T (Kappa = 0.708). Thus, lesion conspicuity and diagnostic confidence could be significantly improved when reading MRL images in consensus with MRI3T (Odds ratio: 9- to 11-fold for the T2w images and 5- to 8–fold for the DWI) (p < 0.001). For measures of lesion size, anterior-posterior and right-left prostate diameter, inter-reader and intersequence agreement were excellent (ICC > 0.90) and there were no significant differences between MRL and MRI3T among all three readers. In terms of Prostate Imaging Reporting and Data System (PIRADS) scoring, no significant differences were observed between MRL and MRI3T. Finally, there was a significant positive linear relationship between lesion ADC measurements (r = 0.76, p < 0.01) between the ADC values measured on both systems. In conclusion, image quality for T2w was comparable and diagnostic even without administration of spasmolytic- or contrast agents, while DWI images did not reach diagnostic level and need to be optimized for further exploitation in the setting of MRgRT. Diagnostic confidence and lesion conspicuity were significantly improved by reading MRL in consensus with MRI3T which would be advisable for a safe planning and treatment workflow. Finally, ADC measurements of lesions on both systems were comparable indicating that, lesion ADC as measured on the MRL could be used as a biomarker for evaluation of treatment response, similar to examinations using MRI3T.

27 August 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
MFMarcel Frueh
Marcel Frueh
TKThomas Küstner
Thomas Küstner
MNMarcel Nachbar
Marcel Nachbar
DTDaniela Thorwarth
Daniela Thorwarth
ASAndreas Schilling
Andreas Schilling
SGSergios Gatidis
Sergios Gatidis
Tracking of anatomical structures in time-resolved medical image data plays an important role for various tasks such as volume change estimation or treatment planning. State-of-the-art deep learning techniques for automated tracking, while providing accurate results, require large amounts of human-labeled training data making their wide-spread use time- and resource-intensive. Our contribution in this work is the implementation and adaption of a self-supervised learning (SSL) framework that addresses this bottleneck of training data generation. To this end we adapted and implemented an SSL framework that allows for automated anatomical tracking without the necessity for human-labeled training data. We evaluated this method by comparison to conventional- and deep learning optical flow (OF)-based tracking methods. We applied all methods on three different time-resolved medical image datasets (abdominal MRI, cardiac MRI, and echocardiography) and assessed their accuracy regarding tracking of pre-defined anatomical structures within and across individuals. We found that SSL-based tracking as well as OF-based methods provide accurate results for simple, rigid and smooth motion patterns. However, regarding more complex motion, e.g. non-rigid or discontinuous motion patterns in the cardiac region, and for cross-subject anatomical matching, SSL-based tracking showed markedly superior performance. We conclude that automated tracking of anatomical structures on time-resolved medical image data with minimal human labeling effort is feasible using SSL and can provide superior results compared to conventional and deep learning OF-based methods.

1 November 2021 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
CGCihan Gani
Cihan Gani
MRMonica Lo Russo
Monica Lo Russo
SBSimon Boeke
Simon Boeke
DWDaniel Wegener
Daniel Wegener
SGSergios Gatidis
Sergios Gatidis
MNMarcel Nachbar
Marcel Nachbar

9 August 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DWDaniel Wegener
Daniel Wegener
ATAlexandra Thome
Alexandra Thome
FPFrank Paulsen
Frank Paulsen
CGCihan Gani
Cihan Gani
JBJessica Boldt
Jessica Boldt
SBSimon Boeke
Simon Boeke
Introduction: Novel MRI-linear accelerator hybrids (MR-Linacs, MRL) promise an optimization of radiotherapy (RT) through daily MRI imaging with enhanced soft tissue contrast and plan adaptation on the anatomy of the day. These features might potentially improve salvage RT of prostate cancer (SRT), where the clinical target volume is confined by the mobile organs at risk (OAR) rectum and bladder. So far, no data exist about the feasibility of the MRL technology for SRT. In this study, we prospectively examined patients treated with SRT on a 1.5 T MRL and report on workflow, feasibility and acute toxicity. Patients and Methods: Sixteen patients were prospectively enrolled within the MRL-01 study (NCT: NCT04172753). All patients were staged and had an indication for SRT after radical prostatectomy according to national guidelines. RT consisted of 66 Gy in 33 fractions or 66.5/70 Gy in 35 fractions in case of a defined high-risk region. On the 1.5 T MRL, daily plan adaption was performed using one of two workflows: adapt to shape (ATS, using contour adaptation and replanning) or adapt to position (ATP, rigid replanning onto the online anatomy with virtual couch shift). Duration of treatment steps, choice of workflow and treatment failure were recorded for each fraction of each patient. Patient-reported questionnaires about patient comfort were evaluated as well as extensive reporting of acute toxicity (patient reported and clinician scored). Results: A total of 524/554 (94.6%) of fractions were successfully treated on the MRL. No patient-sided treatment failures occurred. In total, ATP was chosen in 45.7% and ATS in 54.3% of fractions. In eight cases, ATP was performed on top of the initial ATS workflow. Mean (range) duration of all fractions (on-table time until end of treatment) was 25.1 (17.6–44.8) minutes. Mean duration of the ATP workflow was 20.60 (17.6–25.2) minutes and of the ATS workflow 31.3 (28.2–34.1) minutes. Patient-reported treatment experience questionnaires revealed high rates of tolerability of the treatment procedure. Acute toxicity (RTOG, CTC as well as patient-reported CTC, IPSS and ICIQ) during RT and 3 months after was mild to moderate with a tendency of recovery to baseline levels at 3 months post RT. No G3+ toxicity was scored for any item. Conclusions: In this first report on SRT of prostate cancer patients on a 1.5 T MRL, we could demonstrate the feasibility of both available workflows. Daily MR-guided adaptive SRT of mean 25.1 min per fraction was well tolerated in this pretreated collective, and we report low rates of acute toxicity for this treatment. This study suggests that SRT on a 1.5 T MRL can be performed in clinical routine and it serves as a benchmark for future analyses.

1 July 2021 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
MNMarcel Nachbar
Marcel Nachbar
DMDavid Mönnich
David Mönnich
ODOliver Dohm
Oliver Dohm
MFMelissa Friedlein
Melissa Friedlein
DZDaniel Zips
Daniel Zips
DTDaniela Thorwarth
Daniela Thorwarth
Hybrid magnetic resonance linear accelerator (MR-Linac) systems represent a novel technology for online adaptive radiotherapy. 3D secondary dose calculation (SDC) of online adapted plans is required to assure patient safety. Currently, no 3D-SDC solution is available for 1.5T MR-Linac systems. Therefore, the aim of this project was to develop and validate a method for online automatic 3D-SDC for adaptive MR-Linac treatments. An accelerator head model was designed for an 1.5T MR-Linac system, neglecting the magnetic field. The use of this model for online 3D-SDC of MR-Linac plans was validated in a three-step process: (1) comparison to measured beam data, (2) investigation of performance and limitations in a planning phantom and (3) clinical validation using n = 100 patient plans from different tumor entities, comparing the developed 3D-SDC with experimental plan QA. The developed model showed median gamma passing rates compared to MR-Linac base data of 84.7%, 100% and 99.1% for crossplane, inplane and depth-dose-profiles, respectively. Comparison of 3D-SDC and full dose calculation in a planning phantom revealed that with ⩾5 beams gamma passing rates >95% can be achieved for central target locations. With a median calculation time of 1:23 min, 3D-SDC of online adapted clinical MR-Linac plans demonstrated a median gamma passing rate of 98.9% compared to full dose calculation, whereas experimental plan QA reached 99.5%. Here, we describe the first technical 3D-SDC solution for online adaptive MR-guided radiotherapy. For clinical situations with peripheral targets and a small number of beams additional verification appears necessary. Further improvement may include 3D-SDC with consideration of the magnetic field.