Haidara Almansour

Dr. Haidara Almansour

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Sebastian GassenmaierSebastian Gassenmaier
Sebastian Gassenmaier
TKThomas Küstner
Thomas Küstner
MNMarcel Dominik Nickel
Marcel Dominik Nickel
JHJudith Herrmann
Judith Herrmann
RHRüdiger Hoffmann
Rüdiger Hoffmann
A(Ahmed Othman (MD)
Ahmed Othman (MD)
Deep learning technologies and applications demonstrate one of the most important upcoming developments in radiology. The impact and influence of these technologies on image acquisition and reporting might change daily clinical practice. The aim of this review was to present current deep learning technologies, with a focus on magnetic resonance image reconstruction. The first part of this manuscript concentrates on the basic technical principles that are necessary for deep learning image reconstruction. The second part highlights the translation of these techniques into clinical practice. The third part outlines the different aspects of image reconstruction techniques, and presents a review of the current literature regarding image reconstruction and image post-processing in MRI. The promising results of the most recent studies indicate that deep learning will be a major player in radiology in the upcoming years. Apart from decision and diagnosis support, the major advantages of deep learning magnetic resonance imaging reconstruction techniques are related to acquisition time reduction and the improvement of image quality. The implementation of these techniques may be the solution for the alleviation of limited scanner availability via workflow acceleration. It can be assumed that this disruptive technology will change daily routines and workflows permanently.

1 March 2023 in Radiology
Verified
Journal Article
Closed access
HAHaidara Almansour
Haidara Almansour
JHJudith Herrmann
Judith Herrmann
Sebastian GassenmaierSebastian Gassenmaier
Sebastian Gassenmaier
Saif AfatSaif Afat
Saif Afat
JJJohann Jacoby
Johann Jacoby
A(Ahmed Othman (MD)
Ahmed Othman (MD)
Deep learning–reconstructed turbo spin-echo (TSE) acquisition was interchangeable with standard TSE for detecting various spinal abnormalities at MRI, providing excellent quality and a 70% reductio... Background Deep learning (DL)–based MRI reconstructions can reduce examination times for turbo spin-echo (TSE) acquisitions. Studies that prospectively employ DL-based reconstructions of rapidly ac...

17 July 2021 in Cancers
Verified
Journal Article
Open access
PDF file
Sebastian GassenmaierSebastian Gassenmaier
Sebastian Gassenmaier
Saif AfatSaif Afat
Saif Afat
MNMarcel Dominik Nickel
Marcel Dominik Nickel
MMMahmoud Mostapha
Mahmoud Mostapha
JHJudith Herrmann
Judith Herrmann
A(Ahmed Othman (MD)
Ahmed Othman (MD)
Multiparametric MRI (mpMRI) of the prostate has become the standard of care in prostate cancer evaluation. Recently, deep learning image reconstruction (DLR) methods have been introduced with promising results regarding scan acceleration. Therefore, the aim of this study was to investigate the impact of deep learning image reconstruction (DLR) in a shortened acquisition process of T2-weighted TSE imaging, regarding the image quality and diagnostic confidence, as well as PI-RADS and T2 scoring, as compared to standard T2 TSE imaging. Sixty patients undergoing 3T mpMRI for the evaluation of prostate cancer were prospectively enrolled in this institutional review board-approved study between October 2020 and March 2021. After the acquisition of standard T2 TSE imaging (T2S), the novel T2 TSE sequence with DLR (T2DLR) was applied in three planes. Overall, the acquisition time for T2S resulted in 10:21 min versus 3:50 min for T2DLR. The image evaluation was performed by two radiologists independently using a Likert scale ranging from 1–4 (4 best) applying the following criteria: noise levels, artifacts, overall image quality, diagnostic confidence, and lesion conspicuity. Additionally, T2 and PI-RADS scoring were performed. The mean patient age was 69 ± 9 years (range, 49–85 years). The noise levels and the extent of the artifacts were evaluated to be significantly improved in T2DLR versus T2S by both readers (p < 0.05). Overall image quality was also evaluated to be superior in T2DLR versus T2S in all three acquisition planes (p = 0.005–<0.001). Both readers evaluated the item lesion conspicuity to be superior in T2DLR with a median of 4 versus a median of 3 in T2S (p = 0.001 and <0.001, respectively). T2-weighted TSE imaging of the prostate in three planes with an acquisition time reduction of more than 60% including DLR is feasible with a significant improvement of image quality.

26 March 2021 in Cancers
Verified
Journal Article
Open access
PDF file
HAHaidara Almansour
Haidara Almansour
Saif AfatSaif Afat
Saif Afat
VFVictor Fritz
Victor Fritz
FSFritz Schick
Fritz Schick
MNMarcel Nachbar
Marcel Nachbar
DWDaniel Wegener
Daniel Wegener
The objective of this study is to conduct a qualitative and a quantitative image quality and lesion evaluation in patients undergoing MR-guided radiation therapy (MRgRT) for prostate cancer on a hybrid magnetic resonance imaging and linear accelerator system (MR-Linac or MRL) at 1.5 Tesla. This prospective study was approved by the institutional review board. A total of 13 consecutive patients with biopsy-confirmed prostate cancer and an indication for MRgRT were included. Prior to radiation therapy, each patient underwent an MR-examination on an MRL and on a standard MRI scanner at 3 Tesla (MRI3T). Three readers (two radiologists and a radiation oncologist) conducted an independent qualitative and quantitative analysis of T2-weighted (T2w) and diffusion-weighted images (DWI). Qualitative outcome measures were as follows: zonal anatomy, capsule demarcation, resolution, visibility of the seminal vesicles, geometric distortion, artifacts, overall image quality, lesion conspicuity, and diagnostic confidence. All ratings were performed on an ordinal 4-point Likert scale. Lesion conspicuity and diagnostic confidence were firstly analyzed only on MRL. Afterwards, these outcome parameters were analyzed in consensus with the MRI3T. Quantitative outcome measures were as follows: anteroposterior and right left diameter of the prostate, lesion size, PI-RADS score (Prostate Imaging—Reporting and Data System) and apparent diffusion coefficient (ADC) of the lesions. Intergroup comparisons were computed using the Wilcoxon-sign rank test and t tests. A post-hoc regression analysis was computed for lesion evaluation. Finally, inter-/intra-reader agreement was analyzed using the Fleiss kappa and intraclass correlation coefficient. For T2w images, the MRL showed good results across all quality criteria (median 3 and 4). Furthermore, there were no significant differences between MRL and MRI3T regarding capsule demarcation or geometric distortion. For the DWI, the MRL performed significantly less than MRI3T across most image quality criteria with a median ranging between 2 and 3. However, there were no significant differences between MRL and MRI3T regarding geometric distortion. In terms of lesion conspicuity and diagnostic confidence, inter-reader agreement was fair for MRL alone (Kappa = 0.42) and good for MRL in consensus with MRI3T (Kappa = 0.708). Thus, lesion conspicuity and diagnostic confidence could be significantly improved when reading MRL images in consensus with MRI3T (Odds ratio: 9- to 11-fold for the T2w images and 5- to 8–fold for the DWI) (p < 0.001). For measures of lesion size, anterior-posterior and right-left prostate diameter, inter-reader and intersequence agreement were excellent (ICC > 0.90) and there were no significant differences between MRL and MRI3T among all three readers. In terms of Prostate Imaging Reporting and Data System (PIRADS) scoring, no significant differences were observed between MRL and MRI3T. Finally, there was a significant positive linear relationship between lesion ADC measurements (r = 0.76, p < 0.01) between the ADC values measured on both systems. In conclusion, image quality for T2w was comparable and diagnostic even without administration of spasmolytic- or contrast agents, while DWI images did not reach diagnostic level and need to be optimized for further exploitation in the setting of MRgRT. Diagnostic confidence and lesion conspicuity were significantly improved by reading MRL in consensus with MRI3T which would be advisable for a safe planning and treatment workflow. Finally, ADC measurements of lesions on both systems were comparable indicating that, lesion ADC as measured on the MRL could be used as a biomarker for evaluation of treatment response, similar to examinations using MRI3T.

29 September 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
DWDaniel Wessling
Daniel Wessling
JHJudith Herrmann
Judith Herrmann
Saif AfatSaif Afat
Saif Afat
MNMarcel Dominik Nickel
Marcel Dominik Nickel
HAHaidara Almansour
Haidara Almansour
Sebastian GassenmaierSebastian Gassenmaier
Sebastian Gassenmaier
Purpose: The purpose of this study was to test the technical feasibility and the impact on the image quality of a deep learning-based super-resolution reconstruction algorithm in 1.5 T abdominopelvic MR imaging. Methods: 44 patients who underwent abdominopelvic MRI were retrospectively included, of which 4 had to be subsequently excluded. After the acquisition of the conventional volume interpolated breath-hold examination (VIBEStd), images underwent postprocessing, using a deep learning-based iterative denoising super-resolution reconstruction algorithm for partial Fourier acquisitions (VIBESR). Image analysis of 40 patients with a mean age of 56 years (range 18–84 years) was performed qualitatively by two radiologists independently using a Likert scale ranging from 1 to 5, where 5 was considered the best rating. Results: Image analysis showed an improvement of image quality, noise, sharpness of the organs and lymph nodes, and sharpness of the intestine for pre- and postcontrast images in VIBESR compared to VIBEStd (each p < 0.001). Lesion detectability was better for VIBESR (p < 0.001), while there were no differences concerning the number of lesions. Average acquisition time was 16 s (±1) for the upper abdomen and 15 s (±1) for the pelvis for VIBEStd, and 15 s (±1) for the upper abdomen and 14 s (±1) for the pelvis for VIBESR. Conclusion: This study demonstrated the technical feasibility of a deep learning-based super-resolution algorithm including partial Fourier technique in abdominopelvic MR images and illustrated a significant improvement of image quality, noise, and sharpness while reducing TA.

18 January 2023 in Cancers
Verified
Journal Article
Open access
PDF file
Sebastian GassenmaierSebastian Gassenmaier
Sebastian Gassenmaier
VWVerena Warm
Verena Warm
MNMarcel Dominik Nickel
Marcel Dominik Nickel
EWElisabeth Weiland
Elisabeth Weiland
JHJudith Herrmann
Judith Herrmann
Saif AfatSaif Afat
Saif Afat
Objectives: Thin-slice prostate MRI might be beneficial for prostate cancer diagnostics. However, prolongation of acquisition time is a major drawback of thin-slice imaging. Therefore, the purpose of this study was to investigate the impact of a thin-slice deep learning accelerated T2-weighted (w) TSE imaging sequence (T2DLR) of the prostate as compared to conventional T2w TSE imaging (T2S). Materials and Methods: Thirty patients were included in this prospective study at one university center after obtaining written informed consent. T2S (3 mm slice thickness) was acquired first in three orthogonal planes followed by thin-slice T2DLR (2 mm slice thickness) in axial plane. Acquisition time of axial conventional T2S was 4:12 min compared to 4:37 min for T2DLR. Imaging datasets were evaluated by two radiologists using a Likert-scale ranging from 1–4, with 4 being the best regarding the following parameters: sharpness, lesion detectability, artifacts, overall image quality, and diagnostic confidence. Furthermore, preference of T2S versus T2DLR was evaluated. Results: The mean patient age was 68 ± 8 years. Sharpness of images and lesion detectability were rated better in T2DLR with a median of 4 versus a median of 3 in T2S (p < 0.001 for both readers). Image noise was evaluated to be significantly worse in T2DLR as compared to T2S (p < 0.001 and p = 0.021, respectively). Overall image quality was also evaluated to be superior in T2DLR versus T2S with a median of 4 versus 3 (p < 0.001 for both readers). Both readers chose T2DLR in 29 cases as their preference. Conclusions: Thin-slice T2DLR of the prostate provides a significant improvement of image quality without significant prolongation of acquisition time.