We acquired images of breast malignancies using the Twente photoacoustic mammoscope (PAM), to obtain more information about the clinical feasibility and limitations of photoacoustic mammography. Results were compared with conventional imaging and histopathology. Ten technically acceptable measurements on patients with malignancies and two measurements on patients with cysts were performed. In the reconstructed volumes of all ten malignant lesions, a confined region with high contrast with respect to the background could be seen. In all malignant cases, the PA contrast of the abnormality was higher than the contrast on x-ray mammography. The PA contrast appeared to be independent of the mammographically estimated breast density and was absent in the case of cysts. Technological improvements to the instrument and further studies on less suspicious lesions are planned to further investigate the potential of PAM.

1 December 2019 in Photoacoustics
Verified
Journal Article
Open access
TZTianrui Zhao
Tianrui Zhao
ADAdrien E. Desjardins
Adrien E. Desjardins
SOSebastien Ourselin
Sebastien Ourselin
TVTom Vercauteren
Tom Vercauteren
Wenfeng XiaWenfeng Xia
Wenfeng Xia
Photoacoustic imaging (PAI) is an emerging biomedical imaging modality that is based on optical absorption contrast, capable of revealing distinct spectroscopic signatures of tissue at high spatial resolution and large imaging depths. However, clinical applications of conventional non-invasive PAI systems have been restricted to examinations of tissues at depths less than a few cm due to strong light attenuation. Minimally invasive photoacoustic imaging (miPAI) has greatly extended the landscape of PAI by delivering excitation light within tissue through miniature fibre-optic probes. In the past decade, various miPAI systems have been developed with demonstrated applicability in several clinical fields. In this article, we present an overview of the current status of miPAI and our thoughts on future perspectives.

1 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Wenfeng XiaWenfeng Xia
Wenfeng Xia
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
EMEfthymios Maneas
Efthymios Maneas
NSNaoto Sato
Naoto Sato
YSYusuke Shigeta
Yusuke Shigeta
ADAdrien Desjardins
Adrien Desjardins
Ultrasound imaging is widely used to guide minimally invasive procedures, but the visualization of the invasive medical device and the procedure’s target is often challenging. Photoacoustic imaging has shown great promise for guiding minimally invasive procedures, but clinical translation of this technology has often been limited by bulky and expensive excitation sources. In this work, we demonstrate the feasibility of guiding minimally invasive procedures using a dual-mode photoacoustic and ultrasound imaging system with excitation from compact arrays of light-emitting diodes (LEDs) at 850 nm. Three validation experiments were performed. First, clinical metal needles inserted into biological tissue were imaged. Second, the imaging depth of the system was characterized using a blood-vessel-mimicking phantom. Third, the superficial vasculature in human volunteers was imaged. It was found that photoacoustic imaging enabled needle visualization with signal-to-noise ratios that were 1.2 to 2.2 times higher than those obtained with ultrasound imaging, over insertion angles of 26 to 51 degrees. With the blood vessel mimicking phantom, the maximum imaging depth was 38 mm. The superficial vasculature of a human middle finger and a human wrist were clearly visualized in real-time. We conclude that the LED-based system is promising for guiding minimally invasive procedures with peripheral tissue targets.

15 December 2009 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
DPDaniele Piras
Daniele Piras
Wenfeng XiaWenfeng Xia
Wenfeng Xia
WSWiendelt Steenbergen
Wiendelt Steenbergen
TLTon van Leeuwen
Ton van Leeuwen
SMSrirang Manohar
Srirang Manohar
The Twente photoacoustic mammoscope (PAM) uses pulsed light at 1064 nm to excite PA signals. Detection is using a planar 590-element ultrasound (US) sensor matrix. Image reconstruction uses a delay-and-sum beamforming algorithm. Measurements are performed in the forward mode, with mild compression of the breast against the detector with US coupling gel. We consolidate the most important specifications of the system. Furthermore, we discuss in detail the results of imaging two cases of infiltrating ductal carcinoma and one case of a cyst. We critically discuss the features of the present embodiment and present plans for its improvement.

30 June 2020 in Optics Express
Verified
Journal Article
Open access
TZTianrui Zhao
Tianrui Zhao
SOSebastien Ourselin
Sebastien Ourselin
TVTom Vercauteren
Tom Vercauteren
Wenfeng XiaWenfeng Xia
Wenfeng Xia
Image transmission through multimode optical fibers has been an area of immense interests driven by the demand for miniature endoscopes in biomedicine and higher speed and capacity in telecommunications. Conventionally, a complex-valued transmission matrix is obtained experimentally to link the input and output light fields of a multimode fiber for image retrieval, which complicates the experimental setup and increases the computational complexity. Here, we report a simple and high-speed method for image retrieval based on our demonstration of a pseudo-linearity between the input and output light intensity distributions of multimode fibers. We studied the impact of several key parameters to image retrieval, including image pixel count, fiber core diameter and numerical aperture. We further demonstrated with experiments and numerical simulations that a wide variety of input binary and gray scale images could be faithfully retrieved from the corresponding output speckle patterns. Thus, it promises to be useful for highly miniaturized endoscopy in biomedicine and spatial-mode-division multiplexing in telecommunications.

1 January 2018 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
EMEfthymios Maneas
Efthymios Maneas
Wenfeng XiaWenfeng Xia
Wenfeng Xia
DNDaniil I Nikitichev
Daniil I Nikitichev
BDBatol Daher
Batol Daher
MMManiragav Manimaran
Maniragav Manimaran
ADAdrien E Desjardins
Adrien E Desjardins
Here we describe methods for creating tissue-mimicking ultrasound phantoms based on patient anatomy using a soft material called gel wax. To recreate acoustically realistic tissue properties, two additives to gel wax were considered: paraffin wax to increase acoustic attenuation, and solid glass spheres to increase backscattering. The frequency dependence of ultrasound attenuation was well described with a power law over the measured range of 3-10 MHz. With the addition of paraffin wax in concentrations of 0 to 8 w/w%, attenuation varied from 0.72 to 2.91 dB cm-1 at 3 MHz and from 6.84 to 26.63 dB cm-1 at 10 MHz. With solid glass sphere concentrations in the range of 0.025-0.9 w/w%, acoustic backscattering consistent with a wide range of ultrasonic appearances was achieved. Native gel wax maintained its integrity during compressive deformations up to 60%; its Young's modulus was 17.4 ± 1.4 kPa. The gel wax with additives was shaped by melting and pouring it into 3D printed moulds. Three different phantoms were constructed: a nerve and vessel phantom for peripheral nerve blocks, a heart atrium phantom, and a placental phantom for minimally-invasive fetal interventions. In the first, nerves and vessels were represented as hyperechoic and hypoechoic tubular structures, respectively, in a homogeneous background. The second phantom comprised atria derived from an MRI scan of a patient with an intervening septum and adjoining vena cavae. The third comprised the chorionic surface of a placenta with superficial fetal vessels derived from an image of a post-partum human placenta. Gel wax is a material with widely tuneable ultrasound properties and mechanical characteristics that are well suited for creating patient-specific ultrasound phantoms in several clinical disciplines.