Pedro Molinero-Mourelle

Dr. Pedro Molinero-Mourelle

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Medicina Oral Patología Oral y Cirugia Bucal
Verified
Journal Article
Open access
ALAlvaro Limones
Alvaro Limones
LSLm. Sáez-Alcaide
Lm. Sáez-Alcaide
SDSa. Díaz-Parreño
Sa. Díaz-Parreño
AHA. Helm
A. Helm
MBMm. Bornstein
Mm. Bornstein
PMPedro Molinero-Mourelle
Pedro Molinero-Mourelle
The aim of the present study was to analyse the incidence, risk ratio (RR) and prognoses of two types of medication-related osteonecrosis of the jaws (MRONJ): denosumab-related osteonecrosis of the jaws (DRONJ) and Bisphosphonate-Related Osteonecrosis of the Jaws (BRONJ) in cancer patients under treatment with denosumab or zoledronic acid (ZA). An electronic and manual search was conducted for randomized controlled trials (RCTs) until May 2019. Assessment of the identified studies, risk of bias and data extraction were performed independently by two reviewers. The incidence of DRONJ and BRONJ and the RR to develop MRONJ were calculated at 1 year, 2 years and 3 years of exposure. It was also calculated the odds ratio (OR) of their respective prognoses. They were calculated normalizing the values of the individual studies to 1 year, 2 years or 3 years when necessary through robust regression models using a statistical program. From 1.277 references identified, 8 RCTs were included, which comprised a total of 13.857 patients with a variety of neoplasms. The incidence of DRONJ in cancer patients under treatment with denosumab ranged from 0.5 to 2.1% after 1 year, 1.1 to 3.0% after 2 years, and 1.3 to 3.2% after 3 years of exposure. The incidence of BRONJ in cancer patients under treatment with ZA ranged from 0.4 to 1.6% after 1 year of exposure, 0.8 to 2.1% after 2 years, and 1.0 to 2.3% after 3 years of exposure. Statistically significant differences were found between denosumab and ZA in the risk of developing MRONJ after 1, 2 and 3 years of exposure. Nevertheless, there were no significant differences in terms of patient prognosis. Denosumab is associated with a significantly higher risk of developing MRONJ compared to ZA. Nevertheless, no differences were found in its prognoses.

18 October 2023 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
GSGunjan Srivastava
Gunjan Srivastava
SPSubrat Padhiary
Subrat Padhiary
NMNeeta Mohanty
Neeta Mohanty
PMPedro Molinero-Mourelle
Pedro Molinero-Mourelle
NCNajla Chebib
Najla Chebib
Scanning edentulous arches during complete denture fabrication is a crucial step; however, the quality of the resulting digital scan is still questionable. The purpose of this study is to systematically review studies (both clinical and in vitro) and determine whether intraoral scanners have clinically acceptable accuracy when recording completely edentulous arches for the fabrication of removable complete dentures. An electronic search in medical databases like PubMed, Scopus, and Web of Science (WOS), using a combination of relevant keywords, retrieved 334 articles. After full-text evaluation, twelve articles fulfilled the inclusion criteria for this review (eight clinical studies and four in vitro studies). A quality analysis of the included studies was carried out using the QUADAS-2 tool. The accuracy values varied between different intraoral scanners. Different regions of the edentulous arches showed differences in trueness and precision values in both in vitro and clinical studies. Peripheral borders, the inner seal, and poorly traceable structures like the soft palate showed maximum discrepancies. The accuracy of intraoral scanners in recording clear anatomic landmarks like hard tissues with attached mucosa was comparable to conventional edentulous arch impressions. However, higher discrepancies were recorded when digitizing mobile and poorly traceable structures. Intraoral scanners can be used to digitize denture-bearing areas, but the interpretation of the peripheral border and the soft palate should be carefully carried out.

26 September 2023 in Clinical Oral Implants Research
Verified
Journal Article
Open access
JWJulia‐Gabriela Wittneben
Julia‐Gabriela Wittneben
PMPedro Molinero-Mourelle
Pedro Molinero-Mourelle
AHAdam Hamilton
Adam Hamilton
MAMuhsen Alnasser
Muhsen Alnasser
BOBarbara Obermaier
Barbara Obermaier
DWDaniël Wismeijer
Daniël Wismeijer
Objectives: The aim of this study was to assess the following PIO question: In adult patients treated with an indication for single tooth extraction in the maxillary esthetic zone (15–25), what is the influence of an immediate implant placement and immediate loading protocol on the clinical performance (primary aim) and esthetic outcomes (secondary aim) focusing on investigations published after 2010.Material and Methods: An electronic search in Medline (PubMed), the Cochrane Central Register of Controlled Trials, and EMBASE databases up to April 2022 was performed to identify clinical studies investigating the outcome of single implants subjected to immediate placement with immediate restoration/loading (Type 1A).Results: Sixty‐three studies (10 randomized controlled trials, 28 prospective and 25 retrospective cohort studies) were included with a follow‐up ranging from 12 to 96 months. One thousand nine hundred sixty‐one implants reported survival rates of 99.2 (98.6–99.5) % at 1 year, 97.5 (95.9–98.4) % after 3 years, and 95.8 (93.3–97.4) % after 5 years; 1064 immediately loaded restorations presented survival rates of 98.9 (97.8–99.5) % after 1 year, 96.8 (93.6–98.4) % after 2 years, and 94.8 (89.6–97.4) % after 5 years. Comparing baseline to 12‐month data using the Hedges' g effect size (95% CI), papilla height presented an overall effect size of −0.71 (−1.25, −0.1) mm, midfacial recession change of −0.15 (−0.66, 0.36) mm, and a 0.82 (0.37, 1.28) gain in PES.Conclusions: Immediate implant placement and immediate loading can be considered a predictable and safe treatment option for single maxillary anterior restorations with adequate survival rates and favorable esthetics outcomes for up to 5 years.

16 September 2022 in Materials
Verified
Journal Article
Open access
PDF file
GCGulce Cakmak
Gulce Cakmak
PMPedro Molinero-Mourelle
Pedro Molinero-Mourelle
MPMarcella Silva De Paula
Marcella Silva De Paula
CACanan Akay
Canan Akay
ACAlfonso Rodriguez Cuellar
Alfonso Rodriguez Cuellar
BYBurak Yilmaz
Burak Yilmaz
Three-dimensional (3D) printing is increasingly used to fabricate denture base materials. However, information on the effect of simulated brushing and thermocycling on the surface roughness and color stability of 3D-printed denture base materials is lacking. The aim of this study was to evaluate the effect of brushing and thermocycling on the surface roughness and color stability of 3D-printed denture base materials and to compare with those of milled and heat-polymerized denture base resins. Disk-shaped specimens (Ø 10 mm × 2 mm) were prepared from 4 different denture base resins (NextDent Denture 3D+ (ND); Denturetec (SC); Polident d.o.o (PD); Promolux (CNV)) (n = 10). Surface roughness (Ra) values were measured before and after polishing with a profilometer. Initial color coordinates were measured by using a spectrophotometer after polishing. Specimens were then consecutively subjected to simulated brushing (10,000 cycles), thermocycling (10,000 cycles), and brushing (10,000 cycles) again. Ra and color coordinates were measured after each interval. Color differences (ΔE00) between each interval were calculated and these values were further evaluated considering previously reported perceptibility (1.72 units) and acceptability (4.08 units) thresholds. Data were analyzed with Friedman, Kruskal–Wallis, and Mann–Whitney U tests (α = 0.05). Ra (p ≥ 0.051) and ΔE00 (p ≥ 0.061) values among different time intervals within each material were similar. Within each time interval, significant differences in Ra (p ≤ 0.002) and ΔE00 values (p ≤ 0.001) were observed among materials. Polishing, brushing, and thermocycling resulted in acceptable surface roughness for all materials that were either similar to or below 0.2 µm. Color of ND printed resin was affected by brushing and thermocycling. All materials had acceptable color stability when reported thresholds are considered.

Verified
Journal Article
Open access
PDF file
NHNadin Al-Haj Husain
Nadin Al-Haj Husain
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
PMPedro Molinero-Mourelle
Pedro Molinero-Mourelle
Tim JodaTim Joda
Tim Joda
The aim of this systematic review and meta-analysis was to evaluate the clinical performance of tooth-borne partial and full-coverage fixed dental prosthesis fabricated using hybrid polymer and ceramic CAD/CAM materials regarding their biologic, technical and esthetical outcomes. PICOS search strategy was applied using MEDLINE and were searched for RCTs and case control studies by two reviewers using MeSH Terms. Bias risk was evaluated using the Cochrane collaboration tool and Newcastle–Ottawa assessment scale. A meta-analysis was conducted to calculate the mean long-term survival difference of both materials at two different periods (≤24, ≥36 months(m)). Mean differences in biologic, technical and esthetical complications of partial vs. full crown reconstructions were analyzed using software package R (p < 0.05). 28 studies included in the systematic review and 25 studies in the meta-analysis. The overall survival rate was 99% (0.95–1.00, ≤24 m) and dropped to 95% (0.87–0.98, ≥36 m), while the overall success ratio was 88% (0.54–0.98; ≤24 m) vs. 77% (0.62–0.88; ≥36 m). No significance, neither for the follow-up time points, nor for biologic, technical and esthetical (88% vs. 77%; 90% vs. 74%; 96% vs. 95%) outcomes was overserved. A significance was found for the technical/clinical performance between full 93% (0.88–0.96) and partial 64% (0.34–0.86) crowns. The biologic success rate of partial crowns with 69% (0.42–0.87) was lower, but not significant compared to 91% (0.79–0.97) of full crowns. The esthetical success rate of partial crowns with 90% (0.65–0.98) was lower, but not significant compared to 99% (0.92–1.00) of full crowns.

1 January 2016 in Medicina Oral Patología Oral y Cirugia Bucal
Verified
Journal Article
Open access
PMPedro Molinero-Mourelle
Pedro Molinero-Mourelle
LBLaura Baca-Gonzalez
Laura Baca-Gonzalez
BGB Gao
B Gao
LSL Saez-Alcaide
L Saez-Alcaide
AHA Helm
A Helm
JLJ Lopez-Quiles
J Lopez-Quiles
The use of zygomatic implants in the prosthetic rehabilitation of the patient with severe maxillary bone atrophy is another therapeutic alternative, not exempt from complications. The main objective of this review is to analyze and describe the most frequent surgical complications associated with the use of zygomatic implants. An electronic database search on PubMed, along with a manual search, without taking into account date nor language, was undertaken by two observers, selecting studies that comprised a study period from 6 to 12 months, any type of clinical trial, and series that included a follow-up and/or review period during the aforementioned margin, that mentioned at least two types of complications. Out of the initial search that yielded 455 studies, 67 were considered potentially relevant for the present study, out of which 14 were finally selected. Out of the most frequent surgical complications, sinusitis (3,9%) and failure in osseointegration (2,44%) are highlighted. The analysis of the results shows that the most frequent complications are sinusitis and failure in osseointegration of the zygomatic implant. However, a standardised data collection system for the data on complications is needed.