Chian Yong Liu

Dr. Chian Yong Liu

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2021 in Cureus
Verified
Journal Article
Open access
PDF file
MHMohd Hazim Abd Hamid
Mohd Hazim Abd Hamid
SAShalimar Abdullah
Shalimar Abdullah
AAAmir Adham Ahmad
Amir Adham Ahmad
PSParminder Singh Gill Narin Singh
Parminder Singh Gill Narin Singh
ESElaine Zi Fan Soh
Elaine Zi Fan Soh
JSJamari Sapuan
Jamari Sapuan
Introduction: Distal end radius fractures are common fractures commonly treated with an option of open reduction and plating. Traditionally, plating is performed under general anesthesia (GA) or regional block. Recently, a new technique of plating under wide-awake local anesthesia with no tourniquet (WALANT) has been introduced. We aim to compare the preoperative anxiety level, intraoperative pain scores, post-operative pain scores, operating time, blood loss and clinical outcome of distal end radius plating with WALANT versus GA with tourniquet. Methods: We conducted a randomized controlled study on patients with closed fracture of the distal end of the radius requiring open reduction and plating from January 2019 till April 2020. We recruited 65 patients (33 patients in the WALANT group and 32 patients in the GA group). Randomization was done via block randomization. Data were collected to evaluate preoperative anxiety using the Amsterdam Preoperative Anxiety and Information Scale (APAIS) score, intraoperative pain score during injection (baseline) (V1), 10 minutes after injection (V2), during incision (V3), during gentle manipulation (V4), during aggressive manipulation (V5) and during first drilling of screw (V6), blood loss, duration of surgery and post-operative pain score. Additionally, intraoperative visual analog scale (VAS) score was obtained in the WALANT group. At three weeks, six weeks, three months and six months after operation, the Quick Disabilities of Arm, Shoulder and Hand (QuickDASH) scores and range of motion (ROM) of the wrists were obtained. Results: The average age in the WALANT group was 47.19 (range, 36-64) years and GA group was 49.48 (range, 38-60) years. The mean APAIS score obtained was 7.78 (WALANT group) and 7.36 (GA group) with no statistical difference. For intraoperative VAS, only during V4 and V5 were the scores 1/10; otherwise at all other phases, the VAS score was 0. The average time for surgery was statistically longer in the WALANT group (61.22 minutes) compared to the GA group (55.33 minutes) (p = 0.003). There was no statistical difference in mean blood loss in both groups. The average post-operative VAS showed statistical significance only at 1 hour and 12 hours post-operation with no statistical difference at 2 and 24 hours post-operation. There was no difference in the post-operative ROM including wrist flexion, extension, supination and pronation for both groups up to six months’ follow-up. Conclusion: There was no statistically significant difference in terms of preoperative anxiety level, intraoperative and post-operative VAS score, amount of blood loss and clinical outcome in both groups for plating of the distal end radius. However, the operating time was slightly longer in the WALANT group. We conclude that distal radius plating under WALANT has similar outcomes to GA. In centres with limited resources, WALANT offers a safe, reliable and cheaper option, reserving GA time for head, abdominal and thoracic surgery.

21 July 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MAMahmoud Al-Kadi
Mahmoud Al-Kadi
Mamun Bin Ibne ReazMamun Bin Ibne Reaz
Mamun Bin Ibne Reaz
MAMohd Alauddin Mohd Ali
Mohd Alauddin Mohd Ali
CLChian Yong Liu
Chian Yong Liu
This paper presents a comparison between the electroencephalogram (EEG) channels during scoliosis correction surgeries. Surgeons use many hand tools and electronic devices that directly affect the EEG channels. These noises do not affect the EEG channels uniformly. This research provides a complete system to find the least affected channel by the noise. The presented system consists of five stages: filtering, wavelet decomposing (Level 4), processing the signal bands using four different criteria (mean, energy, entropy and standard deviation), finding the useful channel according to the criteria’s value and, finally, generating a combinational signal from Channels 1 and 2. Experimentally, two channels of EEG data were recorded from six patients who underwent scoliosis correction surgeries in the Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM) (the Medical center of National University of Malaysia). The combinational signal was tested by power spectral density, cross-correlation function and wavelet coherence. The experimental results show that the system-outputted EEG signals are neatly switched without any substantial changes in the consistency of EEG components. This paper provides an efficient procedure for analyzing EEG signals in order to avoid averaging the channels that lead to redistribution of the noise on both channels, reducing the dimensionality of the EEG features and preparing the best EEG stream for the classification and monitoring stage.

15 March 2022 in Cureus
Verified
Journal Article
Open access
WCWeng Ken Chan
Weng Ken Chan
CLChian Yong Liu
Chian Yong Liu
The advancement of supraglottic airways (SGAs) has eased airway management, especially for anesthetists. There were functional improvements implemented to the newer SGA. We aim to assess the clinical performance of laryngeal mask airway (LMA) Protector™ Cuff Pilot™ (Teleflex Inc., Wayne, Pennsylvania, USA) against LMA Supreme™ (Teleflex Inc., Wayne, Pennsylvania, USA), in terms of oropharyngeal leak pressure (OLP), successful insertion attempts, mean insertion time, ease of gastric tube insertion, laryngeal view, and incidence of sore throat among anesthetized, non-paralyzed patients undergoing general anesthesia. In this prospective single-blinded study, 60 patients were randomized to use either LMA Protector™ Cuff Pilot™ or LMA Supreme™. Both groups received standard monitoring and induction regimes. Post-insertion, a bronchoscope was used to verify its position. A gastric tube was inserted and OLP was measured. Patients were assessed during the post-operative period for sore throats. LMA Protector™ Cuff Pilot™ was comparable to LMA Supreme™ in terms of mean OLP (30.72±8.60 vs 27.23±8.09 cmH2O, P = 0.114), first successful attempt (P = 0.312), mean insertion time (27.72±9.45 vs 24.37±6.46 seconds, P = 0.116), and grade 1 laryngeal view (51.7% vs 36.7%, P = 0.244). At first attempt, LMA Protector™ Cuff Pilot™ had a lower success rate of gastric tube insertion than LMA Supreme™ (55.17% vs 96.67%, P <0.001). The incidence of the blood-stained device and sore throat post-operatively were comparable between the two groups. LMA Protector™ Cuff Pilot™ was comparable to LMA Supreme™ in terms of overall clinical performance, except for the first successful gastric tube insertion. Improvements should be made to the gastric channel for easier gastric tube insertion in the LMA Protector™ Cuff Pilot™.

7 January 2025 in IEEE Access
Verified
Journal Article
Open access
NANorizal Abdullah
Norizal Abdullah
Masri AyobMasri Ayob
Masri Ayob
MLMeng Chun Lam
Meng Chun Lam
NSNasser R. Sabar
Nasser R. Sabar
GKGraham Kendall
Graham Kendall
CLChian Yong Liu
Chian Yong Liu
The Anaesthetist Rostering Problem (ARP) presents significant challenges in healthcare management due to complex constraints and regulations. Existing models for the ARP often fail to address the complexities of real-world hospital environments, particularly in integrating monthly and weekly schedules across multiple locations. This study addresses the key question: How can we develop anaesthetist rosters that improve both staff fairness and operational efficiency while meeting complex hospital requirements? To address this challenge, we propose a novel mixed-integer linear programming model with updated constraints, parameters, and an enhanced evaluation function. We implemented the model at Hospital Canselor Tuanku Muhriz (HCTM), Malaysia, to handle various shift types across multiple locations for both monthly and weekly rosters. The proposed model optimises the roster by satisfying mandatory constraints first (such as legal requirements), and then minimising soft constraint violations, such as employee preferences, through iterative refinement. The evaluation function assesses roster quality by minimising penalties for soft constraint violations. We modified the evaluation function and constraints to accommodate HCTM’s specific shift patterns and rest requirements, enhancing fairness, flexibility, and workload distribution. The model reduced penalties by 69.57% for monthly rosters and 64.37% for weekly rosters compared to manual scheduling. Statistical analysis proved significant enhancement in monthly rosters and weekly rosters. The model improves workload fairness and scheduling efficiency, bridging theoretical models and practical applications. It contributes to healthcare workforce management by offering better resource allocation and increased staff satisfaction.

15 August 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
TRThanalachumy Ragunathan
Thanalachumy Ragunathan
RTRufinah Teo
Rufinah Teo
AYAliza Mohamad Yusof
Aliza Mohamad Yusof
SMSiti Nidzwani Mohamad Mahdi
Siti Nidzwani Mohamad Mahdi
AIAzarinah Izaham
Azarinah Izaham
RRRaha Abdul Rahman
Raha Abdul Rahman
Background: A feeding tube (FT) is routinely placed in critically ill patients, and its correct placement is confirmed with a chest X-ray (CXR), which is considered the gold standard. This study evaluated the diagnostic accuracy of ultrasonography (USG) in verifying FT placement compared to a CXR in an intensive care unit (ICU). Method: This was a prospective single-blind study conducted on patients admitted to the ICU of a tertiary hospital in Malaysia. The FT placements were verified through a fogging test and USG at the neck and subxiphoid points. The results of confirmation of FT placement through USG were compared with those obtained using CXRs. Results: A total of 80 patients were included in this study. The FT positions were accurately confirmed by overall USG assessments in 71 patients. The percentage of FT placements correctly identified by neck USG was 97.5%, while the percentage of those identified by epigastric USG was 75%. The corresponding patients’ CXRs confirmed correct FT placement in 76 patients. The overall USG assessment had a sensitivity of 92.11% and specificity of 75%, a positive predictive value of 98.59%, and a negative predictive value of 33.33%. The USG findings also showed a significant association between FT size and BMI. FTs with a size of 14Fr were better visualized (p = 0.008), and negative USG findings had a significantly higher BMI (p < 0.001). Conclusion: USG is a simple, safe, and reliable bedside assessment that offers relatively high sensitivity in confirming correct FT placement in critically ill patients.

LCLai Fong Chan
Lai Fong Chan
CEChoon Leng Eu
Choon Leng Eu
STSeng Fah Tong
Seng Fah Tong
SCSong Jie Chin
Song Jie Chin
SSShalisah Sharip
Shalisah Sharip
TDTuti Iryani Mohd Daud
Tuti Iryani Mohd Daud
Depression is ranked as the second-leading cause for years lived with disability worldwide. Objective monitoring with a standardized scale for depressive symptoms can improve treatment outcomes. This study evaluates the construct and concurrent validity of the Malay Self-Report Quick Inventory of Depressive Symptomatology (QIDS-SR16) among Malaysian clinical and community samples. This cross-sectional study was based on 277 participants, i.e., patients with current major depressive episode (MDE), n = 104, and participants without current MDE, n = 173. Participants answered the Malay QIDS-SR16 and were administered the validated Malay Mini-International Neuropsychiatric Interview (MINI) for DSM-IV-TR. Factor analysis was used to determine construct validity, alpha statistic for internal consistency, and receiver operating characteristic (ROC) analysis for concurrent validity with MINI to determine the optimal threshold to identify MDE. Data analysis provided evidence for the unidimensionality of the Malay QIDS-SR16 with good internal consistency (Cronbach’s α = 0.88). Based on ROC analysis, the questionnaire demonstrated good validity with a robust area under the curve of 0.916 (p < 0.000, 95% CI 0.884–0.948). A cut-off score of nine provided the best balance between sensitivity (88.5%) and specificity (83.2%). The Malay QIDS-SR16 is a reliable and valid instrument for identifying MDE in unipolar or bipolar depression.